ENERGIZE YOUR ENTERPRISE Network Management Card – User Manual 34003991EN/DA Page 2/120 Contents 1 MGE OFFICE PROTECTION SYSTEMS NETWORK SOLUTION 5 1.1 G ENERAL P RESENTATION 5 1.1.1 Connecting the UPS to the Ethernet network 6 1.1.2 Protection of the computers/servers 6 1.1.3 Supervision of the UPS...
Page 5 - MGE Office Protection Systems Network Solution; General Presentation
ENERGIZE YOUR ENTERPRISE Network Management Card – User Manual 34003991EN/DA Page 5/120 1 MGE Office Protection Systems Network Solution 1.1 General Presentation MGE Office Protection Systems Network Solution: provides information on events concerning the supply of power to the computers connected t...
Page 6 - Connecting the UPS to the Ethernet network
ENERGIZE YOUR ENTERPRISE Network Management Card – User Manual 34003991EN/DA Page 6/120 1.1.1 Connecting the UPS to the Ethernet network This function can be performed either through network Cards inserted in the UPS (Network Management Card) or through a software "agent" running on a nearby...
Page 7 - Supervision of the UPSs over the network
ENERGIZE YOUR ENTERPRISE Network Management Card – User Manual 34003991EN/DA Page 7/120 1.1.3 Supervision of the UPSs over the network Depending on your needs, you can either use: Your Internet browser to monitor each UPS, as Management Proxy and Management Card includes a Web server Your company’s ...
Page 9 - sending
ENERGIZE YOUR ENTERPRISE Network Management Card – User Manual 34003991EN/DA Page 9/120 Network Management Cards are compatible with the "Enterprise Power Management" supervision system and with the MGE Office Protection Systems network protection system. Network Shutdown Module Entreprise P...
Page 14 - Installation; Unpacking and check on contents
ENERGIZE YOUR ENTERPRISE Network Management Card – User Manual 34003991EN/DA Page 14/120 2 Installation 2.1 Unpacking and check on contents The installation kit contents: ◗ A Network Management Card (66102) ◗ A serial communication cable for configuration (34003918) ◗ Installation manual (34003905) ...
Page 15 - Installation in the UPS
ENERGIZE YOUR ENTERPRISE Network Management Card – User Manual 34003991EN/DA Page 15/120 Ethernet port LED Colour Activity Description ACT Green ◗ Off ◗ Card not connected to the network. ◗ On ◗ Card connected to the network but without activity ◗ Flashing ◗ Port is active in receiving / transmissio...
Page 17 - Configuration; Configure IP parameters
ENERGIZE YOUR ENTERPRISE Network Management Card – User Manual 34003991EN/DA Page 17/120 3 Configuration 3.1 Configure IP parameters Once the card has started: Connect one end of the cable (34003918) to the Service port. If the environment sensor was previously connected, the card must be restarted ...
Page 18 - Your network is equipped with a DHCP server
ENERGIZE YOUR ENTERPRISE Network Management Card – User Manual 34003991EN/DA Page 18/120 3.1.1 Your network is equipped with a DHCP server The card is configured by default with this service activated. The card automatically collects IP parameters. To know the IP parameters, type 2, the next menu is...
Page 19 - Your network is not equipped with a DHCP server; Test after configuration
ENERGIZE YOUR ENTERPRISE Network Management Card – User Manual 34003991EN/DA Page 19/120 3.1.2 Your network is not equipped with a DHCP server In the main menu enter 2, then 2 again. The menu is displayed: Follow the instructions and enter the static IP parameters. At the end of the menu, wait for t...
Page 20 - Supervision and administration by browser; Optimising the performance of your browser
ENERGIZE YOUR ENTERPRISE Network Management Card – User Manual 34003991EN/DA Page 20/120 4 Supervision and administration by browser ◗ On a computer equipped with a Web browser (Internet Explorer, FireFox or Netscape recommended), enter the address initialised previously in the Installation chapter ...
Page 65 - Server protection; Shutdown criteria managed by the Network Management Card
ENERGIZE YOUR ENTERPRISE Network Management Card – User Manual 34003991EN/DA Page 65/120 5 Server protection 5.1 Set-up of the shutdown parameters The Network Shutdown Module, on protected server boot, subscribes itself automatically to notified applications list and sends its essential data: ◗ IP A...
Page 66 - Backup time before initiating the shutdown procedure
ENERGIZE YOUR ENTERPRISE Network Management Card – User Manual 34003991EN/DA Page 66/120 Start of the shutdown sequence Delay before shutdown Utility failure Remaining autonomy 100% Shutdown after : If remaining time under UPS Shut off Card parameters UPS parameters Shutdown duration Battery capacit...
Page 68 - Protection of a server connected to a controlled outlet
ENERGIZE YOUR ENTERPRISE Network Management Card – User Manual 34003991EN/DA Page 68/120 5.1.2 Controlled outlets Certain UPS models are equipped with controlled outlets (generally 2) which are always dependant on the UPS's main outlet. Shutdown of the main outlet systematically causes shutdown of t...
Page 69 - The different server and UPS shutdown sequences; message
ENERGIZE YOUR ENTERPRISE Network Management Card – User Manual 34003991EN/DA Page 69/120 5.1.3.2 Sequential startup It is possible to delay outlet power-on to reduce inrush currents on startup or to sequence the startup of several devices. Controlled outlet startup after a given time is based on sta...
Page 70 - counter
ENERGIZE YOUR ENTERPRISE Network Management Card – User Manual 34003991EN/DA Page 70/120 Shutdown duration Start shutdown main output Utility failure Utility Battery capacity under: NSM 2 on output 1 NSM 1 on main output Main output Utility restore Start shutdown output 1 Output 1 Shutdown duration ...
Page 71 - Shutdown management with 2 NMC boards
ENERGIZE YOUR ENTERPRISE Network Management Card – User Manual 34003991EN/DA Page 71/120 5.3 Shutdown management with 2 NMC boards Certain UPS can have 2 NMC boards in order to: ◗ Increase the number of protected servers, ◗ Protect 2 groups of server connected to different networks physically separa...
Page 72 - Configuration via RS232
ENERGIZE YOUR ENTERPRISE Network Management Card – User Manual 34003991EN/DA Page 72/120 6 Configuration via RS232 ◗ Use the cord supplied with the card. ◗ Connect the card to a computer equipped with a hyperterminal type emulator. The serial link must be set at 9600 baud, 8 bits, no parity, 1 stop ...
Page 75 - Choice 3: Lost password / Set Login Password to Default
ENERGIZE YOUR ENTERPRISE Network Management Card – User Manual 34003991EN/DA Page 75/120 6.3 Choice 3: Lost password / Set Login Password to Default In the even the login or password is lost, choice 3 enables the return to the default password: -------------------------------------------------------...
Page 76 - Choice 4: Return to Default Configuration
ENERGIZE YOUR ENTERPRISE Network Management Card – User Manual 34003991EN/DA Page 76/120 6.4 Choice 4: Return to Default Configuration Enables restoration of the default configuration of all the card’s parameters ----------------------------------------------------------------------------- MGE UPS S...
Page 77 - Industrial Network Management Card (INMC option)
ENERGIZE YOUR ENTERPRISE Network Management Card – User Manual 34003991EN/DA Page 77/120 7 Industrial Network Management Card (INMC option) 7.1 Presentation 7.1.1 Overview 7.1.2 Functions The Industrial Network Management Card (INMC) provides the same functions than the NMC card described in the pre...
Page 79 - RS232 link configuration and connection
ENERGIZE YOUR ENTERPRISE Network Management Card – User Manual 34003991EN/DA Page 79/120 7.2 Installation 7.2.1 RS232 link configuration and connection Set the SA2 switches like below: The next figure shows the details of the connection in RS232 mode: Pin number Function 1 Received data (input) 2 No...
Page 80 - RS485 link configuration and connection
ENERGIZE YOUR ENTERPRISE Network Management Card – User Manual 34003991EN/DA Page 80/120 7.2.2 RS485 link configuration and connection 7.2.2.1 RS485 connection La liaison EIA RS485, en 2 fils ou en 4 fils, doit être polarisée en un point unique de la ligne et adaptée aux deux extrémités de cette lig...
Page 86 - Configuration of the JBUS/MODBUS communication parameters
ENERGIZE YOUR ENTERPRISE Network Management Card – User Manual 34003991EN/DA Page 86/120 7.2.3 Configuration of the JBUS/MODBUS communication parameters ◗ Use the cord supplied with the card. ◗ Connect the card to a computer equipped with a Hyper terminal type emulator. The serial link must be set a...
Page 90 - Additional Web pages
ENERGIZE YOUR ENTERPRISE Network Management Card – User Manual 34003991EN/DA Page 90/120 7.3 Additional Web pages The INMC card Jbus parameters could be set through the next page:
Page 106 - Appendices; Tables of alarms and events
ENERGIZE YOUR ENTERPRISE Network Management Card – User Manual 34003991EN/DA Page 106/120 8 Appendices 8.1 Tables of alarms and events 8.1.1 Table of alarms List of time dated alarms Alarm on Alarm off Battery fuse blown Battery fuse OK No Battery Battery present Battery temperature fault Battery te...
Page 117 - Glossary
ENERGIZE YOUR ENTERPRISE Network Management Card – User Manual 34003991EN/DA Page 117/120 9 Glossary Bootp: Protocol based on UDP used to allocate an IP address corresponding to an Ethernet card during the startup phase. Defined by the RCF 951 Community name: Access key to access SNMP agent informat...