Page 3 - Introduction; Environmental protection; Substances
34008236EN/AA - Page 3 Introduction Environmental protection MGE UPS SYSTEMS has implemented an environmental-protection policy.Products are developed according to an eco-design approach. Substances This product does not contain CFCs, HCFCs or asbestos. Packing To improve waste treatment and facilit...
Page 4 - Pictograms
34008236EN/AA - Page 4 Introduction Pictograms Important instructions that must always be followed. Information, advice, help. Visual indication. Action. Audio signal. In the illustrations on the following pages, the symbols below are used: LED off LED on LED flashing
Page 5 - Contents
34008236EN/AA - Page 5 Contents 1. Presentation 1.1 Standard positions ...................................................................................................................... 6 Tower position ................................................................................................
Page 6 - Standard positions; Tower position
34008236EN/AA - Page 6 1. Presentation 1.1 Standard positions Tower position Rack position Dimensions (W x H x D) in mm S 1250 RT 2US 1750 RT 2U2000 RT 2U 440 x 86 x 509 S 2500 RT 2US 3000 RT 2U 440 x 86 x 634 S 3000 RT 3U 440 x 131 x 484 S EXB 1250/1750 RT 2U 440 x 86 x 509 S EXB 2500/3000 RT 2U 44...
Page 7 - Evolution S EXB (optional battery module)
34008236EN/AA - Page 7 1. Presentation 1.2 Rear panels Evolution S 2500 / S 3000 Evolution S EXB (optional battery module) 1.3 Control panel (1) USB communication port (2) RS232 communication port (3) Connector for automatic recognition of an additional battery module (4) Slot for optional communica...
Page 8 - Unpacking and contents check
34008236EN/AA - Page 8 2. Installation 2.1 Unpacking and contents check (30) Evolution UPS (31) connection cable to AC-power source ( Evolution S 2500 and S 3000 models only) (32) 2 connection cables for the protected equipment (33) RS232 communication cable (34) USB communication cable (35) 2 syste...
Page 10 - Communication ports; Connection of RS232 or USB communication port (optional)
34008236EN/AA - Page 10 2. Installation 2.4 Communication ports Connection of RS232 or USB communication port (optional) Installation of the communication cards (optional, standard on the Netpack versions) Characteristics of the contact communication port (optional) The RS232 and USB communication p...
Page 11 - FlexPDU
34008236EN/AA - Page 11 2. Installation 2.5 Connection with a FlexPDU (Power Distribution Unit) module (optional) 2.6 Connection with a HotSwap MBP module (optional) The HotSwap MBP module makes it possible to service or even replace the UPS without affecting the connected loads ( HotSwap function)....
Page 12 - HotSwap MBP module operation; UPS start-up with the HotSwap MBP module; HotSwap MBP module test; UPS connection without a FlexPDU or HotSwap MBP module
34008236EN/AA - Page 12 2. Installation HotSwap MBP module operation UPS start-up with the HotSwap MBP module 1 - Check that the UPS is correctly connected to the HotSwap MBP module. 2 - Set switch (53) to Normal position. 3 - Start the UPS by pressing the ON/OFF button (24) on the UPS control panel...
Page 13 - Operation on battery power; Transfer to battery power
34008236EN/AA - Page 13 3. Operation 3.1 Start-up and normal operation 3.2 Operation on battery power Transfer to battery power Low-battery warning Press button (24) for approximately 1 second. ◗ The buzzer beeps once and all the LEDs go ON simultaneously. ◗ If AC input power is available, button (2...
Page 14 - End of battery backup time; Return of AC input power; Remote control connection and test
34008236EN/AA - Page 14 3. Operation End of battery backup time 3.3 Return of AC input power Following an outage, the UPS restarts automatically when AC input power returns (unless the restart function has been disabled via UPS personalisation) and the load is again supplied. 3.4 UPS shutdown 3.5 UP...
Page 15 - ROO
34008236EN/AA - Page 15 3. Operation Contact open: UPS shutdownContact closed: UPS start-up (UPS connected to AC power and AC power is available) Note. The local ON/OFF control using button (24) overrides the remote-control function. Contact open: UPS shutdown, LED (26) goes ON To return to normal o...
Page 16 - Personalisation using external software; Main-output personalisation
34008236EN/AA - Page 16 4. Personalisation using external software Main-output personalisation Voltage-threshold personalisation (1) Low threshold for transfer to battery is 150 V. UPS-sensitivity personalisation UPS ON/OFF personalisation Battery personalisation ◗ Insert the Solution-Pac CD-ROM in ...
Page 17 - Troubleshooting a UPS equipped with the HotSwap MBP module
34008236EN/AA - Page 17 5. Maintenance 5.1 Troubleshooting Troubleshooting a UPS equipped with the HotSwap MBP module Indication Diagnostic Correction 1 When the UPS is started using button (24) , all the LEDs go ON once and the buzzer beeps once, then LED (26) remains ON. The remote power off (RPO)...
Page 18 - Safety recommendations; Battery-module removal
34008236EN/AA - Page 18 5. Maintenance 5.2 Battery-module replacement Safety recommendations The battery can cause electrocution and high short-circuit currents. The following safety precautions are required before servicing the battery components: ◗ Remove watches, rings, bracelets and all other me...
Page 19 - Mounting the new battery module; Maintenance on a UPS equipped with the HotSwap MBP module; 0 Hz training centre
34008236EN/AA - Page 19 5. Maintenance Mounting the new battery module Carry out the above instructions in reverse order. 5.3 Maintenance on a UPS equipped with the HotSwap MBP module 5.4 Training centre ◗ To ensure safety and high performance, use only batteries supplied by MGE UPS SYSTEMS. ◗ Take ...
Page 20 - Technical specifications
34008236EN/AA - Page 20 6. Appendices 6.1 Technical specifications (1) The high and low thresholds can be adjusted using Personal Solution-Pac software. (2) Up to 40 Hz in low-sensitivity mode (programmable using Personal Solution-Pac software. (3) Adjustable to 200 V (10% derating of output power) ...