- Page 2 – Page; TABLE OF CONTENTS; GENERAL INFORMATION
- Page 3 – IMPORTANT SAFETY INSTRUCTIONS; WARNING; HAZARD
- Page 7 – GLOSSARY; This air compressor; INSPECTION
- Page 8 – STORAGE; Protect the electrical cord and; DESCRIPTION OF; an automatic
- Page 9 – INSTALLATION AND; intake
- Page 11 – OPERATING; Daily Star t-up Checklist
- Page 12 – MAINTENANCE; Check for any unusual noise
- Page 13 – SERVICE; Motor
- Page 14 – TROUBLESHOOTING GUIDE; • Move the pressure switch lever to the
- Page 17 – COMPRESSOR MAIntEnAnCE LOG; DAtE
- Page 19 – MAkItA wARRAnty; Servicio y Garantía / Registro de Producto; MAKITA LIMITED ONE YEAR WARRANTY
OWNERS MANUAL FOR
O
il
Free
Air Compressor
MODEL No
$
C
SPECIFICATION CHART
Model #
AC00
1
Horsep
ower
1/6 HP
SCFM @ 40 PSIG
0.58
SCFM @ 90 PSIG
0
.
45
Cut-In Pressure
95
PSI
Cut-Out Pressure
1
25
PSI
Bore
32
mm
Stroke
11
mm
Voltage -Single Phase
120
Motor RPM
3400
Amperage @ max pressure
1.
8
Tank Size
1
Gallon
CSA/US Listed
Yes
Minimum Circuit Requirement: 15 AMPS
*A circuit breaker is preferred. Use only a fuse or circuit
breaker that is the same rating as the branch circuit the air
compressor is operated on. If the air compressor is connected
to a circuit protected by fuses, use time delay fuses.
IMPORTANT — Read the Safety Guidelines and ALL
instructions carefully before operating.
www.makita.com
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Page 2 TABLE OF CONTENTS SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Warning Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 GLOSSARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 3 IMPORTANT SAFETY INSTRUCTIONS *SAVE THESE INSTRUCTIONS* WARNING IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY AND PROPERTY DAMAGE. READ AND UNDERSTAND ALL WARNINGS AND OPERATING INSTRUCTIONS BEFORE USING THIS EQUIPMENT. HAZARD Risk ofUnsafeOperation WHAT CAN...
Page 7 GLOSSARY CFM: Cubic feet per minute. SCFM: Standard cubic feet perminute; a unit of measure of airdelivery. PSIG: Pounds per square inchgauge; a unit of measure ofpressure. CUT-IN PRESSURE: While themotor is off, air tank pressuredrops as you continue to useyour accessory or air tool. Whenthe...