TYPICAL COOLING AND

HEATING SYSTEM

(4-WIRE)

G

Y

W RH RC

Figure 10

110

GAS

VALVE

COOL

COMP

FAN

24 VAC HEAT

TRANSFORMER

110

TYPICAL COOLING AND

HEATING SYSTEM

(5-WIRE)

G

Y

W RH RC

FAN

COOL

COMP

GAS

VALVE

24 VAC HEAT

TRANSFORMER

110

Figure 11

24 VAC COOL

TRANSFORMER

REMOVE

JUMPER

BETWEEN

RH & RC

TYPICAL HOOKUP FOR 3-WIRE

HEAT SYSTEM IF THIRD

WIRE IS FAN WIRE

TYPICAL HOOKUP FOR 2-WIRE

24V HEATING SYSTEM AND

MILLIVOLT SYSTEM

G

Y

W RH RC

Figure 8

GAS

VALVE

110

24 VAC

TRANSFORMER

OR

THERMOPILE

G

Y

W RH RC

Figure 9

GAS

VALVE

110

FAN

24 VAC

TRANSFORMER

Heating Systems

* If replacing a Honeywell TM-11,
tape off wire “R”; connect wire “B”
to terminal “RH.”
** If replacing a Honeywell thermostat
with a clock wire “C,” tape off wire “C”

Cooling Systems

* If both Y and C wire are

present, tape off “C” wire.

Heating/Cooling Systems

4- or 5-Wire with One Transformer

* If both Y and C wire are

present, tape off “C” wire.

Heating/Cooling Systems

5-or 6- Wire with Two Transformers

* If both Y and C wire are

present, tape off “C” wire.

FAN RELAY
COOLING COMPRESSOR
HEATING CONTROL
HEATING TRANSFORMER
COOL TRANSFORMER

G

Y

W RH RC

G

5

4

RC

V

R

*

H

W

F

RH

Tape Off **

C

Tape Off

TC

G

Y

W RH RC

Y

C

G

F

RC

R

V

*

FAN RELAY
COOLING COMPRESSOR
HEATING CONTROL
HEATING TRANSFORMER
COOL TRANSFORMER

FAN RELAY
COOLING COMPRESSOR
HEATING CONTROL
HEATING TRANSFORMER
COOL TRANSFORMER

G

Y

W RH RC

C

Y

G

F

W

V

R

RC

Tape Off

TC

*

FAN RELAY
COOLING COMPRESSOR
HEATING CONTROL
HEATING TRANSFORMER
COOL TRANSFORMER

G

Y

W RH RC

Y

C

G

F

W

4

A

RH

Tape Off

TC

V

R

RC

*

SPECIFICATIONS

24 Volt A.C.

Heat Anticipator: 0.20 to 1.2 Amp. Max.

Electrical Rating: 24 to 30 Volts A.C.

Cold Anticipator: 0 to 1.0 Amp. Max.

SELECTING THERMOSTAT LOCATION

The proper location of the room thermostat is most important to insure that

it will provide a comfortable home temperature. Observe the following general
rules when selecting a location:

1. Locate it about 5 ft. above the floor with a free flow of air.

2. Install it on a partitioning wall, not on an outside wall.

3. Never expose it to direct light or radiation from lamps, sun, fireplaces, etc.

4. Avoid locations close to doors that lead outside, windows, or adjoining

outside walls.

5. Avoid locations close to radiators, warm air registers, or in the direct path of

heat from them.

6. Make sure there are no pipes or duct work in that part of the wall chosen for

the thermostat location.

7. Never locate it in a room that is warmer or cooler than the rest of the home

such as kitchen or hallway or on the opposite side of the wall of a cold or
unused room.

8. The living or dining room is normally a good location, provided there is no

cooking range or refrigerator on opposite side of wall.

INSTALLATION

1. Remove cover from thermostat by pulling outward. Pull thermostat wires

through small holes beside terminal screws on thermostat base and connect
wires to proper terminal screws per wiring diagrams. Note that on some
models wire leads may be connected to terminal screws on

back

of base.

2.

The thermostat can either be mounted to a standard horizontal outlet box
or mounted directly to the wall. The thermostat must be level to assure
optimum performance.

Place level on top of thermostat base and mark hole

locations for mounting screws.Push excess wire into wall or switch box and

plug up hole to prevent drafts from affecting thermostat operation.

Then

attach thermostat base loosely to wall with the two screws provided.

3. Again place level on top of thermostat base to be sure it is level. Then tighten

mounting screws securely and snap on thermostat cover.

HEATING ANTICIPATOR

The heating side of this
thermostat is equipped
with an adjustable heater.

Set heater indicator to
match the current rating of the primary control.

The heater may be adjusted

for current ratings from .2 to 1.2 Amp.

Additional adjustments, if necessary, may be made as follows:

BURNER CYCLES TOO LONG -

Set adjustable heater to a slightly lower dial

setting (1/2 division).

BURNER CYCLES TOO SHORT -

Set adjustable heater to a slightly higher dial

setting (1/2 division).

TECHNICAL ASSISTANCE

If you have any problems installing or using this thermostat, please carefully and
thoroughly review the instruction manual. If you require assistance, please
contact our Technical Assistance Department at 856-234-8803 during regular
business hours between 8:00AM and 4:30PM Eastern Standard Time, Monday
through Friday. You can also receive technical assistance online anytime day or
night at http://www.luxproproducts.com. Our web site offers you answers to the
most common technical questions, and also permits you to email your
questions to our technical support staff at your convenience.

WARRANTY

Limited Warranty: If this unit fails because of defects in materials or

workmanship within three years of date of original purchase, LUX Products
Corporation will, at its option, repair or replace it. This warranty does not cover
damage by accident, misuse, or failure to follow installation instructions. Implied
warranties are limited in duration to three years from date of original purchase.
Some states do not allow limitations on how long an implied warranty lasts, so
the above limitation may not apply to you. Please return malfunctioning or
defective units to the participating retailer from which purchase was made, along
with proof of purchase. Please refer to "TECHNICAL ASSISTANCE" before
returning thermostat. Purchaser assumes all risks and liability for incidental and
consequential damage resulting from installation and use of this unit. Some
states do not allow the exclusion of incidental or consequential damages, so the
above exclusion may not apply to you. This warranty gives you specific legal
rights and you may also have other rights which vary from state to state.
Applicable in the U.S.A. only.

WIRING DIAGRAMS

These diagrams below are provided for new installations or unreferenced wires.

N O T E

if you have an electric system and the blower does not operate after installation,

find the factory installed yellow wire currently attached to the “Y” terminal and move it

to the “A” terminal on the sub-base.

PSM200SA & PSM400SA

VERSATILE DELUXE LOW

VOLTAGE THERMOSTAT

INSTALLATION INSTRUCTIONS

52055

W A R N I N G

The Adjustable Heater (Heat Anticipator) WILL BURN OUT if 25V are

applied directly to thermostat by shorting out the gas valve or primary

control during testing or by incorrect wiring.

PSM400SA

PSM200SA

This product does not contain mercury.

However, this product may replace a unit which

contains mercury and should not be disposed of in the trash. Contact your local waste

management authority for proper disposal instructions for mercury in a sealed glass tube.

If you have any questions, please call (856) 234-8803

RECYCLING

NOTICE

W A R N I N G

Not for use with compressors without time delays.

LUX PRODUCTS CORPORATION

Mt. Laurel, New Jersey 08054, USA
www.luxproproducts.com

© 2008 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Lux Models

All Lux Other