Features - continued

24 volt: Single stage heat pumps and 2

heat/1 cool heat pump systems with

auxiliary and or emergency heat

Separate weekday and weekend

programs

Preprogrammed – 4 periods per day

Not For Use On:

Program defeat (manual/digital mode)

Conventional systems

Non Heat Pump Systems

▪Exclusive Speed Slide

Electric baseboard heat (120/240)

▪Programmable (4 digits) keyboard lock

3 Wire zone values

▪Adjustable heat/cool temperature limits

Dual power –

2 AA batte

ries included

Electrical Ratings:

Backlight display

1.5 Amps per terminal at 24 Volts AC

Celsius or Farenheit

Temperature hold

Terminals –

W2, Y, E, R, B/O, C, G

Temporary temperature override

Temperature Control

: 45° F to 90°F (7°C

to 32°C)

Temporary compressor protection

(service mode)

▪Adjustable temperature swing 1

-9

UPC Code

– 0 21079 11521 1

▪Calibration feature

▪Wallplate available

Master Carton

- 10 units

▪Dual fuel

Saves Energy!