Lux TX9000 - Manual
Lux TX9000 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Attaching Wires; REMOVING THE OLD THERMOSTAT; Note the letters printed near the terminals.; MOUNTING THE UNIT ON THE WALL; affecting the thermostat.; C A U T I O N; Be careful not to drop the body or disturb electronic parts.; Do not allow wires to touch each other or parts on; N O T E; If you are mounting the base to a soft material like plasterboard; WIRING DIAGRAMS; These diagrams below are provided for new installations or; RH RC; TYPICAL COOL HOOKUP; RH RC
- Page 3 – SINGLE STAGE HEAT AND COOL; TYPICAL SINGLE-STAGE HEAT PUMP HOOKUP; REPLACE BATTERIES WHEN; Use Ene; INSTALLING BATTERIES; OPERATION; or DURACELL; THE BUILT IN ENERGY STAR; PROGRAMMING THE UNIT; You can change any preset times and/or temperatures to suit your; OR
- Page 4 – to avoid potential loss of programs.; SETTING THE TIME OF DAY; Rotate dial to RUN position to start the programs or SET; TEMPORARY TEMPERATURE OVERRIDE; TEMPERATURE OVERRIDE AND TEMPERATURE HOLD; ADVANCED FEATURES; ENERGY USAGE MONITOR; TEMPERATURE SWING; FILTER USAGE MONITOR; TEMPERATURE CALIBRATION; Rotate the dial back to the RUN position.
- Page 5 – CHANGING FROM °F TO °C AND A 12HR CLOCK TO A 24HR CLOCK; TECHNICAL SERVICE; “INSTALLING BATTERIES” which shows the JUMPER LOCATIONS; SMART RECOVERY
LUX PRODUCTS CORPORATION
Mt. Laurel, New Jersey 08054 USA
I M P O R T A N T !
Thank you for your confidence in our product. To obtain the
best results from your investment, please read these
instructions and acquaint yourself with your purchase
before installing your new thermostat. Then follow the
installation procedures, one step at a time. This will save
you time and minimize the chance of damaging the
thermostat and the systems it controls. These instructions
may contain information beyond that required for your
particular installation. Please save for future reference.
READ
INSTALLATION
INSTRUCTIONS
FIRST
TX9000 SERIES
SMART TEMP
®
ELECTRONIC THERMOSTAT
HEAT
OFF
COOL
AUTO
ON
FAN
RESET
HOLD
NEXT
RUN
FILTER
SET
SUNDAY
PROGRAM
SET
SATURDAY
PROGRAM
SET
WEEKDAY
PROGRAM
SET
DAY/TIME
DOWN
UP
1500
P a t e n t s P e n d i n g
MO
DAY
HEAT
PM
SIMPLIFIED INSTRUCTIONS
• Press UP/DOWN to set time.
TO SET PROGRAMS
• Rotate Dial to SET
WEEKDAY
TEMPORARY TEMPERATURE OVERRIDE
•Press UP/DOWN to adjust set temperature.
•To clear OVERRIDE press UP/DOWN until
original set temperature appears or wait for
the start tf the next period
TO SET TIME & DAY
• Rotate Dial to SET
DAY/TIME.
• Press UP to change
t d
HEAT
OFF
COOL
AUTO
ON
FAN
RESET
HOLD
NEXT
RUN
FILTER
SET
SUNDAY
PROGRAM
SET
SATURDAY
PROGRAM
SET
WEEKDAY
PROGRAM
SET
DAY/TIME
DOWN
UP
1500
P a t e n t s P e n d i n g
MO
DAY
HEAT
PM
SIMPLIFIED INSTRUCTIONS
• Press UP/DOWN to set time.
TO SET PROGRAMS
• Rotate Dial to SET
TEMPORARY TEMPERATURE OVERRIDE
•Press UP/DOWN to adjust set temperature.
•To clear OVERRIDE press UP/DOWN until
original set temperature appears or wait for
TO SET TIME & DAY
• Rotate Dial to SET
DAY/TIME.
• Press UP to change
DOWN
UP
MO
DAY
HEAT
PM
Choose Hea
t
or Cool
Se
t
Day & Time
Ins
t
alls Easily
Easy
as
1–2–3
INSTALLATION AND OPERATING
INSTRUCTIONS
WARNING:
Use Energizer
®
or DURACELL
®
Alkaline Ba
tt
eries Only.
Energizer
®
is a registered trademark of Eveready Battery Company, Inc.
DURACELL
®
is a registered trademark of The Gillette Company, Inc.
• Press UP/DOWN
to set time.
TO SET TIME & DAY
• Rotate Dial to SET
DAY/TIME.
• Press UP to change
current day.
• Press NEXT.
TO SET PROGRAMS
• Rotate Dial to SET
WEEKDAY,
SATURDAY or
SUNDAY PROGRAM.
• Press UP/DOWN to adjust
start time.
• Press NEXT.
• Press UP/DOWN to adjust
temperature.
• Press NEXT.
• Repeat as needed or rotate
dial to RUN to stop Programming.
TEMPORARY TEMPERATURE OVERRIDE
•Press UP/DOWN to adjust set temperatur
PATENT NO. 5,673,850
e.
•To clear OVERRIDE press UP/DOWN until
original set temperature appears or wait for
the start tf the next period.
TEMPERATURE HOLD
• Press HOLD. Adjust temperature as
desired with UP/DOWN.
•To clear, press HOLD again.
SIMPLIFIED INSTRUCTIONS
The Active Program Period
Liquid Crystal
Display
Fan Switch
System
Switch
Easy to
follow
Instructions
LUX Speed
Dial
®
Thermostat
Body
The Set
Temperature
Thermostat
Cover
Button to Light
Display
FEATURES
52002
•
The Unit can be used with most 24 volt gas, oil or electric heating and air
conditioning systems, single-stage heat pumps or gas millivolt heating
systems. It cannot be used with 120 volt heating systems or multistage heat
pumps. Ask your dealer for other LUX thermostats to control those systems.
•
The Unit is programmable. There are four programming periods per day. Each
period can be programmed separately.
•
You can use the built-in time/temperature programs, or alter them to suit
your schedule. The Unit provides separate programming for every day of the
week- for both heating and cooling. You can override the programmed tempera-
tures for as little as one programming period or for an entire vacation.
•
In cool weather, when the system switch is set to HEAT, the Unit will maintain
cooler “set back” room temperatures to save energy. It will then change to
warmer “comfort” settings — all automatically, at specified times during the day.
•
In warm weather, when the system switch is set to COOL, the Unit will maintain
warmer “set back” room temperatures to save energy. It will then change to
cooler “comfort” settings - all automatically, at specified times during the day.
•
A large liquid crystal display shows time, day of the week, and room and set
temperatures. It will remind you when the filter should be changed in your blower
and track your system’s energy usage.
•
Temperature swing adjustment lets you fine-tune your system for maximum
comfort and economy.
•
A 4-minute minimum on/off time in COOL prevents your air conditioning
system from being damaged.
•
Two Energizer® or DURACELL® “AA” alkaline batteries (not included) are
used to retain your time and temperature programs.
C
A
U
T
I
O
N
• Your thermostat is a precision instrument. Please handle it with care.
• Turn off electricity to the appliance before installing or servicing
thermostat or any part of the system. Do not turn electricity back on
until work is completed.
• Do not short (jumper) across electric terminals at control on furnace or
air conditioner to test the system. This will damage the thermostat and
void your warranty.
• All wiring must conform to local codes and ordinances.
• This thermostat is designed for use with 24 volt and millivolt systems.
The thermostat should be limited to a maximum of 1.0 amps; higher
amperage may cause damage to the thermostat. If you are in doubt,
call your utility company.
INSTALLATION
Please read all instructions carefully before beginning installation.
TOOLS REQUIRED
#1 Phillips screwdriver (small)
Drill with 3/16-in. (4.8mm) bit
THERMOSTAT LOCATION
On replacement installations,
mount the new thermostat in
place of the old one unless the
conditions listed below suggest
otherwise. On new installations,
follow the guidelines listed below.
1. Locate the thermostat on an
inside wall, about 5 ft. (1.5m)
above the floor, and in a room that is used often.
2. Do not install it where there are unusual heating conditions, such as: in direct
sunlight; near a lamp, radio, television, radiator, register, or fireplace; near
hot water pipes in a wall; near a stove on the other side of a wall.
3. Do not locate in unusual cooling conditions, such as: on a wall separating an
unheated room; or in a draft from a stairwell, door, or window.
4. Do not locate in a damp area. This can lead to corrosion that will shorten
thermostat life.
5. Do not locate where air circulation is poor, such as: in a corner or an alcove;
or behind an open door.
6. Do not install the unit until all construction work and painting has been
completed.
7. This thermostat does not require leveling.
C A U T I O N
To avoid electrical shock
and to prevent damage
to the furnace, air condi-
tioner, and thermostat,
disconnect the power
supply before beginning
work. This can be done at the
fuse box, at the circuit breaker, or
at the appliance.
OFF
© COPYRIGHT 2006 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED
1
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Attaching Wires 4. Hold the base against the wall, with the wires coming through wherever it is convenient for wiring. Route the wires to below the terminal block. Position the base for best appearance (to hide any marks from an old thermostat). An optional wall plate is included for covering old mo...
TYPICAL 24 VAC 4-WIRE HOOKUP SINGLE STAGE HEAT AND COOL Y O G W B RH RC Gas Valve or Heater FAN A/C Comp. System XFMR RH-RC JUMPER PROVIDED COMMON TYPICAL 2-TRANSFORMER 24-VAC 5-WIRE HOOKUP SINGLE STAGE HEAT AND COOL Y O G W B RH RC Gas Valve or Heater FAN A/C Comp. Heat XFMR Cool XFMR RH-RC JUMPER ...
To change current day. Open the drop down door on the front of the thermostat. Rotate the dial to the SET DAY/TIME position. You should see the display pictured above with a day ofthe week flashing. When you are finished setting the day and time, rotate the dialto RUN to return to normal operation o...