Page 2 - Keep this manual in a safe place for future reference.; IMPORTANT SAFETY INSTRUCTIONS; SHOCK HAZARD; This sign alerts user about un-insulated
Keep this manual in a safe place for future reference. To replace this manual, download available from Linear Web site:www.linearcorp.com Read Instructions - All safety and operating instructions should be read before installing or operating the VMC1 Video Intercom system.Retain Instructions - The s...
Page 3 - IMPORTANT DO’S & DON’TS
1 ✔ DO ensure that all instructions have been followed before power is applied to system. The installation shall be carried out in accordance with all applicable installation rules. ✔ DO use only Cat-5 & RG-6 and specifi ed wires called out in these instructions. The cable is designed and constr...
Page 4 - Table of Contents
2 Table of Contents Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Rough-in Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 5 - Block Diagram; ROOM STATION
3 Block Diagram - + 1 VOLUME PRIV MON MUS CLEAR HOUSE DOOR AUX 2 3 4 5 6 7 AM ANTENNA FM ANTENNA MASTER STATION TE6DPOWER SUPPLY H628 DATA HUB ROOM STATION DOOR STATION DEDICATED POWER VIDEO DOOR STATION DOOR LOCK - + 1 VOLUME PRIV MON MUS CLEAR HOUSE DOOR AUX 2 3 4 5 6 7 - + 1 VOLUME PRIV MON MUS C...
Page 6 - Introduction
4 Introduction VMC1MB TE6D 101093 226804 250106-2 233103 The VMC1H installation rough-in prepares the home to accommodate the video intercom system. A VMC1MB mounting bracket is necessary for the Master Station. Room stations and the Alloy Color Video Door Station (VMC1VDS) can be mounted directly o...
Page 7 - Materials Required; Tools
5 Materials Required Tools Most are required for purposes of this installation, but may vary according to installer preferences. POWER DRILL WITH 1” AUGER WIRE STRIPPERS/CUTTER TAPE MEASURE PHILLIPS SCREWDRIVER 14/18 GAUGE WIRE 110 PUNCH-DOWN TOOL CAT-5 CABLE DRYWALL SAW HAMMER LEVEL 0-M 0.5 10 50 2...
Page 8 - Overview
6 Overview The VMC1 System Designed for installation in new homes, the VMC1 is a Whole House Color Video Security Intercom system that provides room to room communication, multiple camera support, basic home automation controls, and video security for mid to large residential applications. VMC1 prov...
Page 9 - Wiring Information; Cables and Wiring; Room Station; Cable Type and Confi guration; POS
7 Wiring Information Cables and Wiring Excellent locations to run cables include: • Roof space • False ceilings/ bulkhead area • Through and/or around external walls • Under fl oors (subject to access being available) • Underground in conduit ✓ NOTE: Keep Intercom cables far from any AC wiring. Avoi...
Page 10 - Master Station Rough-In; VMC1MB Master Station Mounting Bracket; WALL STUDS
8 Master Station Rough-In VMC1MB Master Station Mounting Bracket The VMC1MB mounts fl ush with the wall stud and holds the Master Station and Power Supply (See Figure 1). Position the VMC1MB at a suggested height of 4-1/2 to 5-1/2 feet from the fl oor to center of the unit. As all wiring from other ...
Page 11 - VMC1MB Installation - Finished Wall
9 Master Station Rough-In VMC1MB Installation - Finished Wall Cut out an opening in the drywall (Height 7-1/4” x Width 11”) but do not cut right up against the wall stud. Allow 5/8” clearance between drywall opening and stud. This ensures that drywall will overlap bracket (See Figure 2). Slide the V...
Page 12 - Room Station Rough-In; Room Station Mounting; Room Station Auxiliary Activation
10 Room Station Rough-In Room Station Mounting The Room Stations are normally mounted at a height from the fl oor of: 4-1/2’ to 5’. The Room Stations are not designed to be installed outdoors. Room Station Installation - Unfi nished Wall For an unfi nished wall it is recommended that the VMC1HR roug...
Page 13 - Door Station Rough-In; VMC1VDS Door Station Rough-in; VMC1VDS
11 Door Station Rough-In VMC1VDS Door Station Rough-in The VMC1VDS is a metal door station with a 90 degree horizontal viewing area. It is normally mounted at a height from the fl oor of: 55” – 60”. When installing the VMC1VDS be aware of the camera location and the direction of sunlight and other a...
Page 14 - VMC1HR Rough-in Enclosure
12 VMC1VDS-S/BZ Door Station Rough-in The VMC1VDS-S and VMC1VDS-BZ incorporate a wide angle 120 degree horizontal viewing camera into a Door Station. It is normally mounted at a height from the fl oor of: 55” – 60”. Installation of this unit on an exterior wall requires 4 screws and anchors (See Fig...
Page 15 - Power Supply Rough-In; TE6D Power Supply; WARNING; PRE-WIRED SELF CONTAINED TE6D POWER SUPPLY; Power Supply Connections; Figure 6. Opening TE6D Power Supply
13 Power Supply Rough-In TE6D Power Supply The Power Supply unit is pre-wired and self contained, and the wires are tucked inside. To access connection wires, open the Power Supply unit by removing four screws as shown in Figure 6. In the unlikely case that the TE6D electrical connectors become unpl...
Page 16 - Figure 7 - TE6D Power Supply Wiring
14 Power Supply Rough-In Figure 7 - TE6D Power Supply Wiring Power Supply Wiring 1. Run a 14 AWG 120 VAC power cable (including ground) from a dedicated 15-amp circuit breaker to the Master Station Mounting Bracket location. The VMC1 requires a dedicated power source so there’s no interference from ...
Page 17 - Data Hub Wiring; TIA-568A WIRING STANDARD; Green; Figure 8. H628 Data Hub Wiring
15 Data Hub Wiring TIA-568A WIRING STANDARD DATA HUB RJ-45 MODULAR PLUG Cat-5 WIRE COLOR Pin 1 White/Green Pin 2 Green Pin 3 White/Orange Pin 4 Blue Pin 5 White/Blue Pin 6 Orange Pin 7 White/Brown Pin 8 Brown Figure 8. H628 Data Hub Wiring H628 Data Hub The H628 Data Hub is used to connect each stat...
Page 18 - Antenna Installation; Radio Antennas
16 Antenna Installation Radio Antennas VMC1 requires two antennas, one for AM and one for FM reception. The AM antenna is a 25-foot wire the FM antenna is a 25-foot length of coax with a “T” shaped wire dipole at one end that attaches between rafters in the attic. Antenna arrangement is crucial to q...
Page 19 - Auxiliary Output Rough-In; Figure 10. Electric Door Strike Wiring
17 Auxiliary Output Rough-In Figure 10. Electric Door Strike Wiring Chime Activated Control Output Rough-In The Chime Activated Control Output allows for any number of security related automation functions including 10 available door chimes. To connect an auxiliary Chime refer to Figure 10. Refer to...
Page 20 - Appendix A – Available Components
18 Appendix A – Available Components System Master Station with 5.6” TFT LED color screen supporting up to 20 remote stations. Point-to-Point, Point-to-Group and All Call intercom with hands free response. UL 60950 certifi ed VMC1 (White pictured) VMC1-BK (Black) VMC1-BZ (Bronze) Color Video Door St...
Page 21 - Appendix A – Available Components
19 Plexiglas weather shield increases the weather resistance of VMC1VDS to IP31 Smoke Color (VDSWS-T) Appendix A – Available Components Plexiglas weather shield increases the weather resistance of VMC1VDS-BZ/S to IP31 Clear (DSWS) Nightstand station. Provides all of the function of the intercom for ...
Page 23 - For more parts and accessories, please go to
21 Miniature door / window transmitter (DXS-32) 2-Channel Receiver (DXR-702) 12V Control Output switched 110V outlets for lights and other “notifi cation” devices Remote Turn On for Lights AC1 (1 outlet) AC3 (2 outlets) MFG: Xantec/Niles Wire Relay The 284 Leaded Accessory Relay is a 5 amp Form C re...
Page 24 - - Year Limited Warranty
2 - Year Limited Warranty Linear LLC warrants these products to be free of defects for 2 years. The warranty period begins on either (a) the date of purchase or installation date of this product or (b) the date of closing on a new residence in which this product was originally installed. The warrant...