Linear SWC - Manual

Linear SWC

Linear SWC – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
Page: / 32

Table of Contents:

  • Page 2 – Table of Contents; WARNING
  • Page 3 – Pre-installation Information; Always Check the Gate’s Action; Safety Information and Warnings; Regulatory Warnings; THE FOLLOWING FORMATS ARE USED FOR SAFETY NOTES; IMPORTANT INSTALLATION SAFETY INSTRUCTIONS; STEPS BEFORE PROCEEDING
  • Page 4 – Wiring Specifi cations; AC Power Wiring; DO NOT EXCEED THE MAXIMUM; DC Control and Accessory Wiring; wire should be connected in both the operators.; USE COPPER WIRE ONLY!
  • Page 5 – Mounting Pad Installation; Mounting Pad Specifi cations; Maximum gate opening angle is approximately 95 degrees,; INSIDE VIEW OF GATE; INSTALLATION
  • Page 6 – Operator Preparation; Vent Plug Installation; Gate Arm Installation; Setting Left or Right Hand Confi guration; Figure 2. Vent Plug Installation; Figure 4. Gate Plate Installation
  • Page 7 – Choosing Good Harmonics; It is recommended that you; Apply Krylon; Figure 5. Gate Arm Harmonics; CAUTION
  • Page 8 – Operator Setup; Controller Access; The physical bolting; Figure 8. Controller Access
  • Page 9 – Limit Cam Rough Adjustment; and the bottom; Torque Limiter Adjustment; The open and close current sensing may need to be adjusted; Limit Cam Fine Adjustment; Figure 10. Setting Limit Cams
  • Page 10 – Controller Features; Figure 12. Controller Features
  • Page 11 – Indicator Descriptions
  • Page 12 – Terminal Descriptions
  • Page 13 – Operator Accessory Connections; Figure 13. Operator Accessory Connections
  • Page 14 – Basic Controller Programming; The Mid-travel Stop feature is disabled when dual gate
  • Page 15 – Run Alarm and Pre-start Alarm; Run Alarm Off and Pre-start Alarm Off; Maximum Open Direction Current Setting; OPEN; Maximum Close Direction Current Setting; while this function is; CLOSE; MAX CLOSE; RUN ALARM
  • Page 16 – Advanced Controller Programming; Entering Advanced Programming Mode; The factory default sets the; input terminal so successive inputs; SINGLE; input can be set to cause the gate to OPEN; Stagger Mode; This function is used in dual gate installations only.; COMM LINK; Stagger Delay Time; This function is used in dual gate installations only.; The factory
  • Page 17 – Auxiliary Relay Mode; This function will only be displayed in Model SWD operators.; Power Failure Mode; This function is only used with DC swing gate Model SWD.; Fail Safe and Fail Secure are disabled if Stagger Mode is
  • Page 18 – Soft Start/Stop Duration; Changing the; Reset Cycle Count; Maintenance Alert Trigger; MAINT ALERT; Mid-travel Stop Position; still fully open; Motor Type Selection
  • Page 19 – ANTENNA
  • Page 20 – Loop Layout Illustration
  • Page 21 – Safety Edge Layout Illustration; ARNING
  • Page 22 – Photoeye Installation Illustration
  • Page 23 – Dual Gate Installations; The shield wire should be connected COMM LINK terminal; Dual Gate Enable; Dual Gate Enable must be set for all dual gate installations.; The Stagger Time sets the length of the delay for the Stagger Mode.; Gate Operation; Figure 14. COMM LINK Wiring
  • Page 24 – Operation Indications; St; Error Indications
  • Page 25 – Troubleshooting; fr
  • Page 26 – Model SWR Exploded View
  • Page 27 – Model SWC Exploded View
  • Page 28 – Model SWD Exploded View
  • Page 29 – SWR, SWC, SWD Gate Arm Assembly Exploded View
  • Page 30 – Figure 15. Replacing DC Motor Brushes; Model SWD Maintenance; Battery Maintenance; Do not; Repeat for the other brush.
  • Page 31 – Preventative Maintenance; General; Bearings; -Month Preventative Maintenance; FCC Notice
  • Page 32 – Gate Operator Installation Checklist; OR
Loading the manual

SWR - SWC - SWD

Swing Gate Operator

Installation Guide

USA & Canada (800) 421-1587 & (800) 392-0123

(760) 438-7000 - Toll Free FAX (800) 468-1340

www.linearcorp.com

C

US

INTE

R

TEK

CM

L I

S

T E D

Operator models contained in this manual

conform to UL325 standard for use in

Class I, II, III, and IV applications

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Table of Contents; WARNING

SWR • SWC • SWD Swing Gate Operator Installation Guide 227965 Revision X13 3-28-2008 Table of Contents Pre-installation Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Before You Begin... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1A...

Page 3 - Pre-installation Information; Always Check the Gate’s Action; Safety Information and Warnings; Regulatory Warnings; THE FOLLOWING FORMATS ARE USED FOR SAFETY NOTES; IMPORTANT INSTALLATION SAFETY INSTRUCTIONS; STEPS BEFORE PROCEEDING

SWR • SWC • SWD Swing Gate Operator Installation Guide - 1 - 227965 Revision X13 3-28-2008 Pre-installation Information Before You Begin... Before unpacking, inspect the carton for exterior damage. If you fi nd damage, advise the delivery carrier of a potential claim. Inspect your package carefully....

Page 4 - Wiring Specifi cations; AC Power Wiring; DO NOT EXCEED THE MAXIMUM; DC Control and Accessory Wiring; wire should be connected in both the operators.; USE COPPER WIRE ONLY!

SWR • SWC • SWD Swing Gate Operator Installation Guide - 2 - 227965 Revision X13 3-28-2008 Wiring Specifi cations Refer to the following steps for details on power and accessory wiring for the operator. AC Power Wiring 1. Find the listing on this page corresponding to the model, voltage and horsepow...

Other Linear Models

All Linear Other