Linear RE-1 - Manual

Linear RE-1

Linear RE-1 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
Page: / 32

Table of Contents:

  • Page 3 – PRODUCT DESCRIPTION; Operation
  • Page 4 – INSTALLATION INFORMATION; WARNING FOR ALL GATE INSTALLATIONS: TO AVOID; After completing the RE-1 installation; Be sure the fi lter is located no further than two inches from the; Route all telephone wires inside a dedicated; ALWAYS REMOVE POWER PRIOR TO SERVICING; and case ground terminals to a good; Unscrew the terminal screws several turns before inserting
  • Page 5 – For telephone line and earth ground connections.; COMPONENT LOCATIONS; Weatherproof speaker for system operation and programming.
  • Page 6 – WIRING DIAGRAM
  • Page 7 – ENTRY SYSTEM MOUNTING; Pedestal Mounting; TELEPHONE WIRING; Telephone Bypass Module; ALL TELEPHONE; Telephone Wiring
  • Page 8 – TELEPHONE WIRING OPTIONS; Shared Line; In this mode, remote programming, call forwarding or alternate; Ring Down Mode
  • Page 9 – MULTIPLE UNIT INSTALLATIONS; terminals will be; • Set one unit’s command prefi x to
  • Page 10 – CONTROL WIRING; Gate Control; For operator wiring specifi cs, refer to the gate operator’s wiring; Door or Pedestrian Gate Control
  • Page 11 – Power Wiring; DO NOT APPLY POWER UNTIL THE IN; Backup Battery; Backup batteries are not required to maintain the RE-1 clock/; Earth Ground; OPTIONAL REMOTE KEYPAD
  • Page 12 – OPTIONAL KEYSWITCH; KNOX COMPANY MODEL; KNOX COMPANY
  • Page 13 – OPTIONAL CCTV CAMERA; jack is used to connect the camera to the main; VIDEO; jack is for connection to a video cable with a Type “BNC”; Disconnect the wiring harness connector and remove the antenna; CAMERA
  • Page 14 – PROGRAMMING ACCESS; Programming with a Computer; These requirements are for a PC running the WindowsTM; Select; Be sure to disconnect when programming is completed.
  • Page 15 – THREE BOXE; SETTING UP A WINDOWS XPTM DIAL-UP NETWORK CONNECTION
  • Page 16 – CONNECTING TO THE RE-1 WITH WINDOWS XPTM
  • Page 17 – SETTING UP A WINDOWS VISTATM DIAL-UP NETWORK CONNECTION (PART 1)
  • Page 18 – SETTING UP A WINDOWS VISTATM DIAL-UP NETWORK CONNECTION (PART 2)
  • Page 19 – CONNECTING TO THE RE-1 WITH WINDOWS VISTATM
  • Page 20 – LOCAL PROGRAMMING ACCESS; Programming with a Local Telephone or the Unit’s Keypad; Refer to the next section for details of the; REMOTE PROGRAMMING ACCESS; Remote Programming with a Telephone; Remote Telephone Connection
  • Page 21 – PROGRAMMING REFERENCE; PROGRAMMING CONTROL; Programming worksheets are supplied at the rear of this manual
  • Page 22 – Sets the number of digits for all the entry codes programmed.
  • Page 23 – TRANSMITTER PROGRAMMING; WARNING: Performing this command will remove all; TELEPHONE PROGRAMMING; NORMAL
  • Page 24 – ADVANCED SYSTEM PROGRAMMING
  • Page 26 – SYSTEM ADJUSTMENTS; Speakerphone Volume; SPEAKERPHONE VOLUME; adjustment controls the audio; Digital Speech Volume; adjustment controls the audio level; HELP; the; DIGITAL SPEECH VOLUME; to suit the installation.
  • Page 28 – RESIDENT PROGRAMMING QUICK REFERENCE; assumes that the default has not been changed.
  • Page 29 – SPECIFICATIONS; DIMENSION DRAWING; If you are programming the call forwarding feature as “on at all; local
  • Page 30 – PROGRAMMING WORKSHEET; SYSTEM PROGRAMMING
  • Page 32 – LINEAR LIMITED WARRANTY; There are no obligations; All implied warranties, including implied warranties; This; IMPORTANT WIRELESS INFORMATION
Loading the manual

RE-1

Residential Telephone
Entry System

With Built-in Wireless Receiver

(760) 438-7000

USA & Canada (800) 421-1587 & (800) 392-0123

Toll Free FAX (800) 468-1340

www.linearcorp.com

Installation,
Programming,
and Operation Instructions

PRINTER’S INSTRUCTIONS:

INSTR,INSTL,RE-1 - LINEAR P/N: 217490 C - INK: BLACK - MATERIAL: 20 LB. MEAD BOND WITH 80 LB. WHITE COATED COVER - SIZE: 8.500” X 11.000” - SCALE: 1-1 - FOLDING: ALBUM-FOLD - BINDING: SADDLE-STITCH

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - PRODUCT DESCRIPTION; Operation

1 PRODUCT DESCRIPTION Linear’s RE-1 Telephone Entry System is designed for residential or light commercial access control applications. The speakerphone, keypad, radio receiver, and optional video camera are housed in a rugged enclosure that can be mounted to a pedestal or bolted directly to a wall....

Page 4 - INSTALLATION INFORMATION; WARNING FOR ALL GATE INSTALLATIONS: TO AVOID; After completing the RE-1 installation; Be sure the fi lter is located no further than two inches from the; Route all telephone wires inside a dedicated; ALWAYS REMOVE POWER PRIOR TO SERVICING; and case ground terminals to a good; Unscrew the terminal screws several turns before inserting

2 INSTALLATION INFORMATION Before beginning installation, please review the entire instructions and become familiar with the system’s operation, wiring, and programmable options. System Location For pedestrian door or gate installations, mount the Entry System on a rigid wall near the controlled doo...

Page 5 - For telephone line and earth ground connections.; COMPONENT LOCATIONS; Weatherproof speaker for system operation and programming.

3 12 RELAY TERMINAL BLOCK For Relay #1 and Relay #2 output connections to the access control devices. 13 RELAY INDICATORS Indicators for Relay #1 and Relay #2 will light when the relay is activated. 14 ANTENNA TERMINAL BLOCK For shield and center conductor connection of the coax cable from the syste...

Other Linear Models

All Linear Other