Liebert 1000 - 3000VA 60 Hz 120V - Manual

Liebert 1000 - 3000VA 60 Hz 120V

Liebert 1000 - 3000VA 60 Hz 120V – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
Page: / 36

Table of Contents:

  • Page 3 – TABLE OF CONTENTS
  • Page 4 – ii
  • Page 5 – iii; FIGURES
  • Page 6 – iv
  • Page 7 – SAVE THESE INSTRUCTIONS; install or operate this UPS.; is disconnected. For service, contact a qualified technician.; CAUTION; cloth is recommended to remove dust from the surface of your UPS.; WARNING
  • Page 8 – NOTE
  • Page 9 – Glossary of Symbols; LOSSARY
  • Page 10 – Introduction; NTRODUCTION; the; Specifications; section for details.; Figure 1
  • Page 11 – Figure 2
  • Page 12 – Major Components; AJOR; Figure 5; Transient Voltage Surge Suppression (TVSS) and EMI/RFI Filters; line and keep the sensitive equipment protected.; Relay; Input
  • Page 13 – Automatic Voltage Regulator; utility voltage fluctuations without utilizing the batteries.; Battery Charger
  • Page 14 – What’s Included; HAT; The PowerSure PSI is shipped with the following items:
  • Page 15 – Installation; NSTALLATION; Preparation; or Liebert representative.; or; Rack-Mount UPS Conversion; Tower UPS Installation; Figure 7; The UPS is heavy (see; Table 4 - Battery cabinet specifications; when lifting or moving it.; UPS operation in temperatures above 77°F (25°C) reduces battery life.
  • Page 16 – Rack-Mount UPS Conversion and Installation; Figure 8; the inner members to their outermost position (see; Figure 9; used to move the UPS into and out of the rack.; lowest possible rack position.
  • Page 17 – Figure 10 Rack mounting rails and slide assemblies
  • Page 18 – Option 1 - Serial Communications; Option 2 - Contact Closure Communications; manual, are on the CD included in the PowerSure PSI package.; Option 3 - USB Communications; Windows XP and 2000 and Mac OS 10.2 or later (see; Option 4 – Intellislot; munications operate in parallel.; connection
  • Page 19 – Figure 11 REPO switch connections; External Battery Cabinet Installation; Steps 1
  • Page 20 – Controls and Indicators; ONTROLS; until a new alarm condition is detected.; OFF Button; will shut down the UPS. An audible alarm sounds briefly.
  • Page 21 – Figure 12 Load level indicators—4 green, 1 amber; pensate for a high utility voltage condition (see; detected, indicating that the batteries need to be replaced (see; Troubleshooting
  • Page 22 – Over Temp Indicator—Amber; Fault Indicator—Red; shooting
  • Page 23 – Modes of Operation; ODES; Normal Mode; Figure 14 Normal mode operation with 26-50% load; green when the UPS is operating in Boost mode (see; Indicator shows
  • Page 24 – Battery Mode; shows the; Figure 16 Battery mode at 61 – 80% battery capacity; For more information, refer to; For approximate battery run times, refer to; Table 5 - Battery run times; . These run times are; Battery Recharge Operation; Battery Indicator
  • Page 25 – Communications; OMMUNICATIONS; tions using Liebert ESP II protocol.; Remote Shutdown Via the DB-9 Connector; Link software, the UPS remains Off until a manual restart.; Table 1; Assignment Description; Pin Assignment
  • Page 26 – USB Interface Port; The PowerSure PSI is equipped with an Intellislot; OCWEBCARD disables the Serial Communications of the DB-9.
  • Page 27 – Voltage Programming Procedure; OLTAGE; Figure 18 Load Level Indicators; be flashing, indicating the default setting of 120V as shown in; Utility power will be applied to the
  • Page 28 – Maintenance; AINTENANCE; Cleaning the UPS; The following will help ensure trouble-free operation for years:; Maintaining Batteries; months to ensure full recharge of the batteries.; Battery Replacement; your local dealer or Liebert representative immediately.
  • Page 29 – Internal Battery Replacement Procedure; Figure 19 Battery replacement procedure
  • Page 30 – ROUBLESHOOTING; Table 2 - Troubleshooting chart; for suggested remedy.; Figure 20 Status indicators; problem persists, refer to; Table 2; All indicators illuminated
  • Page 31 – will trip the branch circuit breaker.
  • Page 32 – PECIFICATIONS; Table 3
  • Page 33 – Table 4
  • Page 34 – Table 5
  • Page 35 – To register for warranty protection, visit the; Quick Links; section of our Web site at:; Product Warranty Registration; and complete the form.
  • Page 36 – Emerson Network Power.; The global leader in enabling Business-Critical Continuity.; EmersonNetworkPower.com; The Company Behind the Products; Via Leonardo Da Vinci 8
Loading the manual

Power Protection for

Business Critical Continuity

Liebert PowerSure PSI™

User Manual
1000 - 3000VA, 60 Hz, 120V

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - TABLE OF CONTENTS

i TABLE OF CONTENTS I MPORTANT S AFETY I NSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.0 G LOSSARY OF S YMBOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2.0 I NTRODUCTION . ....

Page 4 - ii

ii 7.2 Buck/Boost Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 7.3 Battery Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 7.4 Battery ...

Page 5 - iii; FIGURES

iii FIGURES Figure 1 Front view of UPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Figure 2 1000 and 1440VA PSI—rear view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

Other Liebert Models

All Liebert Other