Lennox XP25 024 230 01 - Manual

Lennox XP25 024 230 01

Lennox XP25 024 230 01 Heat Pump – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
Page: / 16

Table of Contents:

  • Page 2 – Slab Side Mounting; Elevated Slab Mounting using Feet; Outside Unit Placement; IMPORTANT —; DETAIL A
  • Page 3 – WARNING; BASE WITH ELONGATED LEGS; lush existing line set per industry standards. For
  • Page 4 – CAUTION; NOTE —­; Up to 50 Linear Fee
  • Page 5 – Table 1. Standard Refrigerant Line Set — Up to 50 Linear Feet; Liquid Line; Table 2. Line Set Guidelines Between — 51 ­ 150 Linear Length; Note ­ Shaded rows indicate rated liquid line size
  • Page 6 – OR; FLUSHING LINE SET; FIGURE 2
  • Page 7 – PIPING PANEL REMOVAL / PREPARING LINE SET; CAP AND CORE REMOVAL
  • Page 8 – BRAZE LINE SET; FIGURE 4
  • Page 9 – STEP 3 -- INSTALLING INDOOR EXPANSION VALVE; Product Specifications bulletin; NOTE
  • Page 10 – CONNECT GAUGE SET; TEST FOR LEAKS; Close the valve on the HFC-410A cylinder and the valve on; FIGURE 6
  • Page 11 – absolute pressure; Possible equipment damage.
  • Page 12 – 4VAC TRANSFORMER; NO T E; — Unit s ar e appr ov ed for us e only wit h copper; — 24VAC, Class II circuit connections are made; INSTALL THERMOSTAT; FIGURE 8
  • Page 13 – FIGURE 9
  • Page 14 – ROUTE CONTROL WIRES
  • Page 15 – All outdoor unit setup is completed using the iComfort; Homeowner Information; Outdoor Coil
  • Page 16 – warm; Preservice Check; COOLING MODE; minus
Loading the manual
Page 1

Page 1

E

2018 Lennox Industries Inc.

Dallas, Texas, USA

THIS MANUAL MUST BE LEFT WITH THE

HOMEOWNER FOR FUTURE REFERENCE

General

This XP25 outdoor heat pump is designed for use with
HFC-410A refrigerant only.

These instructions are intended as a general guide and do
not supersede local codes in any way. Consult authorities
having jurisdiction before installation.

THIS UNIT IS A INTEGRAL COMPONENT OF A SYSTEM THAT
WILL REQUIRE AN ICOMFORT

WI-FI

®

THERMOSTAT AND

ICOMFORT™-ENABLED AIR HANDLER OR FURNACE.

XP25

iComfort

WI-FI

®

IMPORTANT

: BEFORE APPLYING ANY POWER (MAIN, SOLAR

OR LOW VOLTAGE) TO THE OUTDOOR UNIT, THE FIELD MUST
CONFIRM ICOMFORT

Wi-Fi

®

THERMOSTAT HAS VERSION 2.1

OR HIGHER SOFTWARE. (REFERENCE ICOMFORT

WI-FI

®

THERMOSTAT MANUAL

)

iComfort™-enabled

air handler or

furnace

INSTALLATION
INSTRUCTIONS

Dave Lennox

Signature

®

Collection XP25 System

HEAT PUMPS
507005-01
7/2018

PACKING LIST

OUTDOOR UNIT

WARRANTY
CARD

GROMMETS (2)

BUSHING (1)

RAST 6-PIN

CONNECTOR (1)

WARNING

Improper installation, adjustment, alteration, service or
maintenance can cause property damage, personal inju­
ry or loss of life.

Installation and service must be performed by a licensed
HVAC professional installer (or equivalent) or service
agency.

STEP 1 -- SETTING THE UNIT -- Clearances

CONTROL

PANEL ACCESS

LOCATION

6 (152)

36 (914)

12 (305)

30 (762)

24

(610)

LINE SET

CONNECTIONS

ACCESS PANEL

REAR VIEW OF UNIT

48 (1219)

MINIMUM CLEARANCE BETWEEN TWO UNITS

CLEARANCE ON ALL SIDES — INCHES (MILLIMETERS)

MINIMUM CLEARANCE

ABOVE UNIT

NOTES:

S

Clearance to access panel must be 30
inches (762mm).

S

Clearance to one of the other three
sides must be 36 inches (914mm).

S

Clearance to one of the remaining two
sides may be 12 inches (305mm) and
the final side may be 6 inches
(152mm).

Note: Dimensions are not to scale.

FIGURE 1

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

About this manual

Brand
Lennox
Model
XP25 024 230 01
Document type
Manual
Category
Heat Pump
Language(s)
English
Pages
16
Format
PDF

Summary

Page 2 - Slab Side Mounting; Elevated Slab Mounting using Feet; Outside Unit Placement; IMPORTANT —; DETAIL A

Page 2 LEG DETAIL BASE 2” (50.8MM) SCH 40 FEMALE THREADED ADAPTER ONE BRACKET PER SIDE (MIN.); FOR EXTRA STABILITY, TWOBRACKETS PER SIDE, 2” (50.8MM) FROM EACH CORNER. CONCRETE SLAB — USE TWO PLASTIC ANCHORS (HOLE DRILL 1/4”) COIL BASE PAN CORNER POST STABILIZING BRACKET (18 GAUGE METAL — 2” WIDTH; ...

Page 3 - WARNING; BASE WITH ELONGATED LEGS; lush existing line set per industry standards. For

Page 3 XP25 SERIES NOTICE ! Roof Damage!This system contains both refrigerant and oil. Somerubber roofing material may absorb oil, causing therubber to degrade. Failure to follow this noticecould result in damage to roof surface. IMPORTANT ! Exhaust vents from dryers, water heaters andfurnaces shoul...

Page 4 - CAUTION; NOTE —­; Up to 50 Linear Fee

Page 4 IMPORTANT ! If this unit is being matched with an approved line set orindoor unit coil that was previously charged with mineraloil, or if it is being matched with a coil which wasmanufactured before January of 1999, the coil and lineset must be flushed prior to installation. Take care toempty...

Ask a question

Up to 3 photos. Max 5 MB each. Formats: JPG, JPEG, PNG, WebP.