Lennox LSM45MN-2 - Manual
Lennox LSM45MN-2 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – TABLE OF CONTENTS; Step 10. Burner Adjustments; Please read and understand these; • Secure VentTM; WARNING; GENERAL INFORMATION
- Page 3 – Table 1; edition, or the Canadian Electrical Code, CSA
- Page 4 – Flame appearance will diminish 4% per; Table 4; Figure 1; Table 2; REQUIREMENTS FOR ThE COMMON-; Figure 2
- Page 5 – LOCATION; Figure 3; Figure 3 - Typical Installation; COLd CLIMATE INSULATION; Cross Corner
- Page 6 – Horizontal Vent Termination Clearances; Side Elevation View; Termination heights For Vents; VENT TERMINATION CLEARANCES; These instructions should be used as a guide-; Vertical Vent Termination Clearances; Figure 4; horizontal Vent Termination Clearances; Figure 6; Minimum; Figure 4 - Multiple Terminations
- Page 7 – ExTERIOR hORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS; Minimum Clearances; K = Clearance to mechanical air supply inlet; Figure 7; NOTE: Local Codes Or Regulations May Require
- Page 8 – Shelf height; Figure 8; MINIMUM CLEARANCES TO COMBUSTIBLES; When; Figure 9; Top Vent - with 2 Feet Vertical Vent and One 90 degree Elbow
- Page 9 – Unit Being Secured by Its Nailing; Adjust burner to ensure; dO NOT; dETAILEd INSTALLATION STEPS; see; TYPICAL INSTALLATION SEQUENCE; Page 9
- Page 10 – Fireplace dimensions; FIREPLACE ANd FRAMING SPECIFICATIONS; Framing dimensions
- Page 11 – Schedule 40 Pipe; Table 6; Proper Sizing of Gas Line; Right Side; Step 2. ROUTING GAS LINE
- Page 12 – VENT RESTRICTOR INSTALLATION; Step 3. INSTALL ThE VENT SYSTEM; Approved Vent Components; on; any of the joints in the vent pipe.
- Page 13 – Figure 17 and Figures 25 through 27 on; Secure VentTM; roof and/or adjacent walls is specified in ANSI; Effective Vent Length; Model; Table 7
- Page 14 – Figure
- Page 15 – Figure 22 - Roof Framing; Swivel Joint; ) can be installed in the; Storm
- Page 16 – Top Vent - ThREE ELBOWS; Table B; Ceiling; Table A; Maximum; VERTICAL VENT FIGURES/TABLES; • Secure VentTM (rigid vent pipe) is shown; A Vent Restrictor, as shown in Figure 15 on
- Page 17 – TYPICAL HORIZONTAL VENT INSTALLATION; Support the vertical portion of the venting system; to
- Page 18 – For wall thicknesses greater than; Table 8; Venting Connection and Exterior Wall Recessing; See; Step B; IMPORTANT: The vent termination is hot
- Page 19 – Termination Kit and 6 In. Vent; range of exterior wall thicknesses.; zontal vent run is needed, then; hORIZONTAL VENT FIGURES/TABLES; • Secure VentTM components (rigid vent pipe and terminal) are shown
- Page 21 – CAUTION; Figures 35 and; the current CSA C22-1 Canadian; Verify proper operation after servicing.; ELECTRONIC; out opening and into the unit junction box.; Section B for electronic appliances. The gas
- Page 22 – Step 5. REMOVE GLASS dOOR FRAME; Glass Enclosure Panels on; Step 6. CONNECTING GAS LINE; Bring the shutoff valve on the end of the flex-line; Gas; Min; WIRING
- Page 23 – Never use an open flame to; Brush all joints and connections with the gas; Millivolt Appliance Checkout
- Page 24 – Excessive use of embers may result in sooting or poor flame.; Place logs 2 and 3; Mixture Of Volcanic Stone And Vermiculite
- Page 25 – Log Number
- Page 27 – Figure 52 - Burner Flame Appearance; To adjust the flame, rotate the air shutter toward; Use the extension knob (refer to; continually operated, adjust the air shutter; Main Burner Factory Air Shutter; Burner Air Shutter Adjustment Procedure
- Page 28 – FINIShING REQUIREMENTS; door track and the surface of the finish material.
- Page 29 – APPOSITION dES MISES EN GARdE RELATIVES; COLOCACIóN dE AdVERTENCIAS dE; ) o en el termostato de pared; LENNOx hEARTh PROdUCTS; WARNINGS; ) and if used on the; Figure A
- Page 30 – INSTALLATION ACCESSORIES
- Page 31 – Kit part numbers are listed here and the fol; assume les responsabilités liées à la conversion.; Burner Assembly
- Page 32 – VERIFY ThE PROPER ORIFICE SIZE; the orifice. Use pipe joint compound or; Millivolt & Electronic Gas Valves; Millivolt & Electronic Pilot Assemblies; Table 9
- Page 33 – NOTES
INSTALLATION INSTRUC
TIONS
P/N 850026M Rev. G 06/2011
This manual is one of a set of two supporting this product.
Refer to P/N 875027M for Care and Operation Instructions.
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 850026CF.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other gases unless a certified kit is used.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATEUR : Laissez cette notice avec l'appareil.
CONSOMMATEUR : Conservez cette notice pour
consultation ultérieure.
AVERTISSEMENT : Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d’incindie ou d’explosion ou pour
éviter tout dommage matériel, toute blessure ou la mort.
WARNING: If the information in these instructions
is not followed exactly, a fire or explosion may
result, causing property damage, personal injury,
or death.
WARNING /AVERTISSEMENT/AVISO
• HOT GLASS WILL CAUSE
BURNS.
• DO NOT TOUCH GLASS
UNTIL COOLED.
• NEVER ALLOW CHILDREN
TO TOUCH GLASS.
• UNE SURFACE VITRÉE CHAUDE
PEUT CAUSER DES BRÛLURES.
• LAISSER REFROIDIR LA SURFACE
VITRÉE AVANT D'Y TOUCHER.
• NE PERMETTEZ JAMAIS À UN ENFANT
DE TOUCHER LA SURFACE VITRÉE.
• EL VIDRIO CALIENTE
CAUSARÁ QUEMADURAS.
• USTED DEBE NUNCA
TOCAR EL VIDRIO CALIENTE.
• LOS NIÑOS DEBEN NUNCA
TOCAR EL VIDRIO.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS:
• Do not t
ry to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a
neighbor’
s phone. Follow the gas supplier
’s
instructions.
• If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
- Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs
ou liquides inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteu
r. Ne pas vous servir des
téléphones se trouvant dans le bâtiment où vous trouvez.
• Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
-
L
’installation et l’entretien doivent être assurés par un
installateur ou un service d’entretien qualifié ou par le
fournisseur de gaz.
OTL Report No. 116-F-22-5
US
Portland
Montebello
®
Direct Vent Gas Fireplaces
MODELS
LSM40MN-2
LSM40MP-2
LSM45MN-2
LSM45MP-2
MILLIVOLT:
LSM40EN-2
LSM45EN-2
ELECTRONIC:
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 LENNOX HEARTH PRODUCTS • MONTEBELLO ® DV GAS FIREPLACES (LSM40/45MN-2, LSM40/45MP-2, LSM40/45EN-2) • INSTALLATION INSTRUCTIONS TABLE OF CONTENTS Packaging .........................................Page 2Introduction ......................................Page 2General Information ......................
3 LENNOX HEARTH PRODUCTS • MONTEBELLO ® DV GAS FIREPLACES (LSM40/45MN-2, LSM40/45MP-2, LSM40/45EN-2) • INSTALLATION INSTRUCTIONS Note: Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service pe...
4 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MONTEBELLO ® DV GAS FIREPLACES (LSM40/45MN-2, LSM40/45MP-2, LSM40/45EN-2) • INSTALLATION INSTRUCTIONS These appliances must be isolated from the gas supply piping system (by closing their individual manual shut-off valve...