Lennox CI1500DVF - Manual

Lennox CI1500DVF

Lennox CI1500DVF – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
Page: / 20

Table of Contents:

  • Page 2 – Installation and repair should be performed; TABLE OF CONTENTS; Front Glass Enclosure Panel,; your home heating needs.
  • Page 3 – Variable Flame Height Adjustment; Control Compartment Access; Figure 3; Burner; Figure 1; Gas Controls; Pull open lower door to access Valve Contols; Figure 2; Table 3
  • Page 4 – Maintenance; Models with Porcelain Enamel Finish; Crazing of Porcelain Enamel:; Porcelain; Cleaning Enamel Surfaces:
  • Page 5 – MAINTENANCE SCHEDULE
  • Page 6 – EXERCISE EXTREME CAUTION; to prevent; Burner Adjustments; Flame Appearance and Sooting:; Open both Latches as shown.; Figure 4; Burner Flame Appearance; Locate and open the 2 latches as shown in
  • Page 7 – Burner Air Shutter Adjustment; Table 6
  • Page 8 – Log Placement; Figure 9; Left Front Log
  • Page 9 – Embers; Place the glowing embers on the burner; Proper Pilot Flame Appearance; SIT Millivolt Appliance Checkout; MILLIVOLT; Small Area Paint Touch-up
  • Page 10 – LHP; The model number of the appliance.; Power Cord; Blower Wiring Diagram
  • Page 12 – ACCESSORY COMPONENTS CONTINUED; Brickaded Liner Kits
  • Page 13 – LIGHTING INSTRUCTIONS – SIT MILLIVOLT GAS VALVE; FOR YOUR SAFETY READ BEFORE LIGHTING; WHAT TO DO IF YOU SMELL GAS; TO TURN OFF GAS TO APPLIANCE; Knob cannot be turned from “PILOT” to “OFF”; SIT
  • Page 14 – INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT SIT; INSTRUCTIONS D'ALLUMAGE; Il est impossible de tourner le bouton de “PILOT” à “OFF” à; POUR FERMER LE GAZ QUI ALIMENTE L’APPAREIL; VANNE GAZ MILLIVOLT SIT
  • Page 15 – TROUBLESHOOTING THE MILLIVOLT GAS CONTROL SYSTEM; SYMPTOM; on page 9
  • Page 16 – Description; Miscellaneous Parts; REPLACEMENT PARTS LIST
  • Page 18 – REPLACEMENT PARTS
  • Page 19 – Front View
  • Page 20 – REFERENCE INFORMATION; If Optional Warming Shelves are purchased, install as follows:; Optional Warming Shelves Kit; Phillips Screwdriver; Cleaning Enamel
Loading the manual

FREESTANDING

VENTED GAS

FIRED ROOM

HEATERS

HOMEOWNERS CARE AND

OPERATION INSTRUCTIONS

Report No. 116-S-08-5

Model CI1500DVF Series

Model CI2500DVF Series

Serefi na Series Direct Vent Gas Stoves

P/N 775,148M Rev. B, 11/04

AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE
LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE
POUR RÉDUIRE AU MINIMUM LE RISQUE D’INCENDIE
OU POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE
BLESSURE OU LA MORT.

WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE.

FOR YOUR SAFETY: Do not store or use gasoline
or other fl ammable vapors or liquids in the vicinity
of this or any other appliance.

FOR YOUR SAFETY: What to do if you smell gas:

• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s
phone. Follow your gas suppliers instructions.
• If your gas supplier cannot be reached, call

the fi re department.

Installation and service must be performed by
a qualifi ed installer, service agency or the gas
supplier

.

POUR VOTRE SÉCURITÉ: Ne pas entreposer ni utiliser
d’essence ni d’autre vapeurs ou liquides infl ammables dans
le voisinage de cet appareil ou de tout autre appareil.

POUR VOTRE SÉCURITÉ: Que faire si vous sentez une
odeur de gaz:

• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucun interrupteur. Ne pas vous servir
des téléphones se trouvant dans le batiment où vous
vous

trouvez.

• Evacuez la piéce, le bâtiment ou la zone.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service dos incendies.

L’installation et service doit être exécuté par un qualifi é
installeur, agence de service ou le fournisseur de gaz.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Installation and repair should be performed; TABLE OF CONTENTS; Front Glass Enclosure Panel,; your home heating needs.

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 2 These appliances are designed to operate on natural or propane gas only. Input of millivolt models is variable. These rates are shown in the following table: INTRODUCTION The Stove models covered in this manual are Direct-Vent sealed combustion vent...

Page 3 - Variable Flame Height Adjustment; Control Compartment Access; Figure 3; Burner; Figure 1; Gas Controls; Pull open lower door to access Valve Contols; Figure 2; Table 3

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 3 HI L O W TPTH TP TH PILO T PIL O T ON it O F F HI / LO Knob Variable Flame Height Adjustment Manifold Pressure Port Inlet Pressure Port Main Gas Control Knob Piezo Igniter IN OUT CARBON MONOXIDE POISONING: EARLY SIGNS OF CARBON MONOXIDE POISONING AR...

Page 4 - Maintenance; Models with Porcelain Enamel Finish; Crazing of Porcelain Enamel:; Porcelain; Cleaning Enamel Surfaces:

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 4 CAUTION: DO NOT ATTEMPT TO TOUCH THE FRONT ENCLOSURE GLASS WITH YOUR HANDS WHILE THE STOVE IS IN USE. Variable Flame Height Adjustment All Millivolt appliances are equipped with a variable gas control valve. Flame height for these models may be adju...

Other Lennox Models

All Lennox Other