Lennox ADAGIO-MN - Manual
Lennox ADAGIO-MN – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – TABLE OF CONTENTS; Please read and understand these; Note: Installation and repair should be per-; WARNING
- Page 3 – Table 1; Table 2; Table 5; Table 3; Table 5; Propane tanks are at pressures
- Page 4 – Note: An Optional Screen Door; Surveiller les enfants. Garder les; Inspection
- Page 5 – The location should also be free of electrical, plumbing or other; CAUTIONS; MANUFACTURED HOME; This appliance may be installed in an after-; COLD CLIMATE INSULATION; Top View
- Page 6 – APPLIANCE AND VENT CLEARANCES; Figure 1; Mantel Clearances; Figure 4; requirements to the nailing flange located at; SHELF HEIGHT; Figure 2
- Page 7 – Figure 5; ExTERIOR HORIZONTAL VENT TERMINATION; VENT TERMINATION CLEARANCES
- Page 8 – Figure 7; TYPICAL INSTALLATION SEQUENCE; Horizontal Vent Termination Clearances; Figure 6; Termination Heights For Vents; Horizontal Vent Termination Clearances; Side Elevation View
- Page 9 – FIREPLACE FRAMING SPECIFICATIONS; Inches; Framing With Platform; Figure; DO NOT; Figure 8
- Page 10 – FIREPLACE SPECIFICATIONS
- Page 11 – FACADE SPECIFICATIONS; Gated Facades
- Page 12 – Figures 17, and 23 through 25 on Pages; Step 2. ROUTING GAS LINE; * Measured from the top of; FPO
- Page 13 – Ceiling Framing
- Page 14 – refer
- Page 15 – Storm; Secure Vent
- Page 16 – VERTICAL VENT FIGURES/TABLES; Maximum; rate Sections of Concentric Flexible; Ceiling; Top Vent - THREE ELBOWS
- Page 18 – Figure 9; IMPORTANT; The vent termination is hot while in; Termination Guard
- Page 19 – Under no circumstances, may separate sections of; HORIZONTAL VENT FIGURES/TABLES; Square termination; Termination Kit Only; Table 7
- Page 20 – to a maximum horizontal run of 20 feet.
- Page 21 – SECuRE FLEX
- Page 22 – Note: The supplied 15 feet of 2 conductor wire; ELECTRONIC; Note: The electronic appliance must be con-; OPTIONAL BLOWER KIT; CAUTION
- Page 23 – Remove the glass door assembly before; BLOWER CONTROL CIRCUIT WIRING; WIRING - OPTIONAL FORCED AIR; Installing Glass Enclosure Panels; - Glass Door Latches; Pull Latches
- Page 24 – Figure 39 - Control Compartment; Step 7. CONNECTING GAS LINE; Secure all joints tightly using appropriate; Never use an open flame to; Gas; Flare Fitting; Gas Solid Line Connector; Trap; GAS CONNECTION; TEST ALL CONNECTIONS FOR GAS LEAKS; - Glass Door Removal
- Page 25 – Glowing Embers; Bag of Glowing; Ember Burner Ports; Figure 41 - Log Set and Glowing Embers; tions provided in kit, before proceeding to Step 9.; bag of glowing embers is located in the bottom compartment. Refer; Remove the front glass enclosure panel
- Page 26 – Figure 47 - Ember Placement; DO NOT place ember material directly
- Page 27 – Step 11. BURNER ADJUSTMENTS; Ensure front glass panel are in; Flame Appearance and sooting; TION; Note: Lighting Instructions are also found on the; Millivolt Appliance Checkout
- Page 28 – Figure 51 - Burner Air Shutter; Adjust the rod to the full closed position for; Valve
- Page 29 – standard hearth extension installation requirements.
- Page 30 – INSTALLATION ACCESSORIES
- Page 31 – GAS CONVERSION KITS; Millivolt; Millivolt Appliances
- Page 32 – Millivolt & Electronic Gas Valves; Millivolt & Electronic Pilot Assemblies; Figure 56 - Burner Orifice; Table 8
Report No. 116-F-48-5
INSTALLATION INSTRUCTIONS MANUAL
Direct-Vent Gas
Fireplace Heaters
Do not store or use gasoline or other flammable
vapors or liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS:
• Do not light any appliance.
• Do not touch any electrical switch; do not
Use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow your gas supplier's
instructions.
• If your gas supplier cannot be reached, call
the fire department.
Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier
.
WARNING: If the information in these instructions
are not followed exactly, a fire or explosion may
result causing property damage, personal injury
or loss of life.
A French manual is available upon request. Order P/N 850,044CF.
Ce manuel d’installation est disponible en francais, simplement
en faire la demande. Numéro de la pièce 850,044CF.
These appliances may be installed in an aftermarket permanently located, manufactured (mobile) home, where
not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases unless a certified kit is used.
Adagio™ Series
US
P/N 850,044M Rev. D, 06/2008
I
n the Commonwealth of Massachusetts:
• Installation must be performed by a licensed plumber or gas fitter
• See Table of Contents for location of additional Commonwealth of
Massachusetts requirements
Millivolt Models
..
Electronic Model
ADAGIO-MN
.....
ADAGIO-EN
ADAGIO-MP
TM
DR
AF
T
6/0
5/2
00
8
Installer: Leave This Manual With The Appliance.
Consumer: Retain This Manual For Future Reference.
Ne pas entreposer ni utiliser d’essence ou d’autres produits
ou liquides inflammables à proximité de cet appareil ou
de tout autre appareil de chauffage.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d’allumer l’appareil.
• Ne pas toucher aux interrupteurs électriques; ne pas
utiliser un téléphone dans le bâtiment.
• Aller immédiatement chez un voisin pour téléphoner
au fournisseur du gaz et suivre leurs instructions.
• Si le fournisseur de gaz n’est pas disponible, appeler
les pompiers.
L’installation et l’entretien doivent être assurés par un
installateur certifié, une société de service spécialisée
ou le fournisseur de gaz.
AVERTISSEMENT : S’assurer de bien suivre les instruc-
tions données dans ce guide pour minimiser les risques
d’incendie ou d’explosion pouvant entraîner des dom-
mages matériels, des blessures ou la mort.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. TABLE OF CONTENTS Packaging .........................................Page 2 Introduction ......................................Page 2 General Information ..........................Page 2 Appliance and Vent Clearances ........Page 4 New York City...
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Input (BTU/HR) Manually-Modulated Gas Valves (millivolt models) Model NATURAL GAS (BTU / HR) PROPANE GAS (BTU / HR) ADAGIO-MN 1,000 high 10,000 low ------------- ADAGIO-MP ------------- 1,000 high 10,000 low Table 1 Input (BTU/HR) Electronic Model...
4 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. WARNING Failure to comply with the instal- lation and operating instructions provided in this document will result in an improperly installed and operating appliance, voiding its warranty. Any change to this appliance and/or its operating contro...