Page 2 - Installation and repair should be performed; TABLE OF CONTENTS; Front Glass Enclosure Panel,; your home heating needs.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 2 These appliances are designed to operate on natural or propane gas only. Input of millivolt models is variable. These rates are shown in the following table: INTRODUCTION The Stove models covered in this manual are Direct-Vent sealed combustion vent...
Page 3 - Variable Flame Height Adjustment; Control Compartment Access; Figure 3; Burner; Figure 1; Gas Controls; Pull open lower door to access Valve Contols; Figure 2; Table 3
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 3 HI L O W TPTH TP TH PILO T PIL O T ON it O F F HI / LO Knob Variable Flame Height Adjustment Manifold Pressure Port Inlet Pressure Port Main Gas Control Knob Piezo Igniter IN OUT CARBON MONOXIDE POISONING: EARLY SIGNS OF CARBON MONOXIDE POISONING AR...
Page 4 - Maintenance; Models with Porcelain Enamel Finish; Crazing of Porcelain Enamel:; Porcelain; Cleaning Enamel Surfaces:
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 4 CAUTION: DO NOT ATTEMPT TO TOUCH THE FRONT ENCLOSURE GLASS WITH YOUR HANDS WHILE THE STOVE IS IN USE. Variable Flame Height Adjustment All Millivolt appliances are equipped with a variable gas control valve. Flame height for these models may be adju...
Page 5 - MAINTENANCE SCHEDULE
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 5 Maintenance Task Accomplishing Person Procedure Inspecting/Cleaning Burner, Logs and Controls Qualifi ed Service Technician Inspect valve and ensure it is properly operating. Check piping for leaks. Vacuum the control compartment, fi replace logs an...
Page 6 - EXERCISE EXTREME CAUTION; to prevent; Burner Adjustments; Flame Appearance and Sooting:; Open both Latches as shown.; Figure 4; Burner Flame Appearance; Locate and open the 2 latches as shown in
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 6 Front Glass Enclosure Panel, Removal and Installation. To install the front glass enclosure panel, proceed as follows: 1. Retrieve the glass door frame. Visually inspect the gasket on the backside of the panel. The gasket surface must be clean, free...
Page 7 - Burner Air Shutter Adjustment; Table 6
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 7 ENSURE THAT THE FRONT GLASS PANEL IS IN PLACE AND SEALED DURING ADJUSTMENT. Adjustment CAUTION: THE ADJUSTMENT ROD AND NEARBY APPLIANCE SURFACES ARE HOT. EXERCISE CAUTION TO AVOID INJURY WHILE ADJUSTING FLAME APPEARANCE. Initially, always position t...
Page 8 - Log Placement; Figure 9; Left Front Log
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 8 Log Placement WARNING: THE SIZE AND POSITION ON THE LOG SET WAS ENGINEERED TO GIVE YOUR APPLIANCE A SAFE, RELIABLE AND ATTRACTIVE FLAME PATTERN. ANY ATTEMPT TO USE A DIFFERENT LOG SET IN THE STOVE WILL VOID THE WARRANTY AND WILL RESULT IN INCOMPLETE...
Page 9 - Embers; Place the glowing embers on the burner; Proper Pilot Flame Appearance; SIT Millivolt Appliance Checkout; MILLIVOLT; Small Area Paint Touch-up
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 9 With proper care and maintenance, your appli-ance will provide many years of enjoyment. If you should experience any problem, fi rst refer to the troubleshooting guide in this manual. If problem persists, contact your Lennox distributor. Embers Figu...
Page 10 - LHP; The model number of the appliance.; Power Cord; Blower Wiring Diagram
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 10 WIRING DIAGRAMS Wiring diagrams are provided here for reference purposes only. This information is also provided on schematics attached directly to the appliance on a pullout panel located within the control compartment. CAUTION: LABEL ALL WIRES PR...
Page 12 - ACCESSORY COMPONENTS CONTINUED; Brickaded Liner Kits
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 12 Side View of Warming Shelf ACCESSORY COMPONENTS CONTINUED Brickaded Liner Kits The brickade liner kits include panels for the rear and side walls of the fi rebox. The panels have brick-like features in relief. These kits can be retrofi tted into pr...
Page 13 - LIGHTING INSTRUCTIONS – SIT MILLIVOLT GAS VALVE; FOR YOUR SAFETY READ BEFORE LIGHTING; WHAT TO DO IF YOU SMELL GAS; TO TURN OFF GAS TO APPLIANCE; Knob cannot be turned from “PILOT” to “OFF”; SIT
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 13 6. Wait fi ve (5) minutes to clear out any gas. If you then smell gas, STOP! Follow “B” in the safety information above on this page. If you do not smell gas, go to the next step. 7. Push in gas control knob slightly and turn counterclockwise to “P...
Page 14 - INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT SIT; INSTRUCTIONS D'ALLUMAGE; Il est impossible de tourner le bouton de “PILOT” à “OFF” à; POUR FERMER LE GAZ QUI ALIMENTE L’APPAREIL; VANNE GAZ MILLIVOLT SIT
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 14 INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT SIT INSTRUCTIONS D'ALLUMAGE 8. Enfoncez le bouton de réglage jusqu’au fond et gardez-le enfoncé. Allumez immédiatement la veilleuse en déclenchant l’allume-gaz à étincelle (en poussant le bouton) jusqu’...
Page 15 - TROUBLESHOOTING THE MILLIVOLT GAS CONTROL SYSTEM; SYMPTOM; on page 9
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 15 TROUBLESHOOTING THE MILLIVOLT GAS CONTROL SYSTEM Note: Before troubleshooting the gas control system, be sure external gas shut off valve (located at gas supply inlet) is in the “ON” position. Important: Valve system troubleshooting should only be ...
Page 16 - Description; Miscellaneous Parts; REPLACEMENT PARTS LIST
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 16 Gas Controls Item # Part/Cat. No. Description Where Used 1 H1657 Valve Assembly – Natural Gas, SIT All 30 H2211 Gas Train Assembly, MV, Natural Gas (LP units will also require LB-102158A) CI1500DVF Series 30 H2212 Gas Train Assembly, MV, Natural Ga...
Page 18 - REPLACEMENT PARTS
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 18 Cast Body Components (continued) Item # Part/Cat. No. Description Where Used 25 H1007 Side Casting, Left - Enamel Hunter Green, 1 ea. CI1506DVF 25 H1031 Side Casting, Left - Enamel Hunter Green, 1 ea. CI2506DVF 25 H2174 Side Casting, Left - Enamel ...
Page 19 - Front View
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 19 2 REPLACEMENT PARTS 18 L E N N O X 7 5 8 3 6 9 11 12 13 14 17 1 19 25 L E N N O X 26 24 22 21 20 27 28 29 23 * * * Front View * * * * * * 10 Front View 4 16 Log Set Does Not Include Ember Strip (purchased separately) 15 30 29b
Page 20 - REFERENCE INFORMATION; If Optional Warming Shelves are purchased, install as follows:; Optional Warming Shelves Kit; Phillips Screwdriver; Cleaning Enamel
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Printed in U.S.A. © 2003 Lennox Hearth Products P/N 775,148M REV. B 11/2004 REFERENCE INFORMATION If Optional Warming Shelves are purchased, install as follows: Optional Warming Shelves Kit Kit Contents: 2 ea. Warming Shelves4 ea. Decorative Brackets4...