- Page 2 – MODULE TILT ANGLE; BOLTING; MAKE CONNECTIONS WHILE UNDER LOAD.
- Page 3 – KYOCERA Solar Group Sales Office
- Page 4 – Thermal Characteristics: Temp. Coefficient; Class A; NOTES; under standard test conditions (irradiance of 1000W/m
INSTALLATION MANUAL
FOR THE
OF
SOLAR PHOTOVOLTAIC POWER MODULES
Please read this manual carefully before installing the modules.
KYOCERA
6C-208590
1. INTRODUCTION
As the world leader in the development and application of
high technology ceramic/silica materials, Kyocera offers a
wide range of highly efficient and reliable crystalline silicon
solar photovoltaic (PV) power modules. Kyocera began to
extensively research PV technology in 1975 and
commenced manufacturing operations in 1978. Since then,
Kyocera has supplied millions of cells and modules
throughout the world. With years of experience and
state-of-the-art technology, Kyocera provides the highest
quality PV power modules in a range of sizes designed to
meet the requirements of the most demanding energy and
power users worldwide.
2. APPLICATIONS
KDxxxGX-LPx series modules are a reliable, virtually
maintenance-free direct current (DC) power source,
designed to operate at the highest level of efficiency.
KDxxxGX-LPx series modules are ideal for remote home,
water pumping, utility-tied, telecommunications and
many other applications either with or without using
storage batteries.
3. WARNINGS & SAFETY
PV modules generate electricity when exposed to light.
Arrays of many modules can cause lethal shock and
burn hazards. Only authorized and trained personnel
should have access to these modules. To reduce the risk
of electrical shock or burns, modules may be covered
with an opaque material during installation. Do not touch
live terminals with bare hands. Use insulated tools for
electrical connections. Do not use these modules for
solar concentration.
PERMIT
・
Before installing your PV system, contact local
authorities to determine the necessary permits,
installation and inspection requirements.
INSTALLATION AND OPERATION
・
Systems should be installed by qualified personnel only.
The system involves electricity, and can be dangerous if
the personnel are not familiar with the appropriate safety
procedures.
・
Do not step on the module.
・
Although
KDxxxGX-LPx
series modules are quite
durable, the glass can be broken (and the module will no
longer work properly) if it is dropped or hit by tools or
other objects.
・
The module frame is made of anodized aluminum, and
therefore corrosion can occur if the module is subject to
a salt-water environment and is in contact with another
type of metal (electrolytic corrosion). If required, PVC or
stainless steel washers can be placed between PV
module frame and support structure to prevent this type
of corrosion.
・
KDxxxGX-LPx
series module frame(s) must be
attached to a support structure by one of the methods
described in Section 6, Installing
KDxxxGX-LPx
series
module(s).
・
Module support structures to be used to support
KDxxxGX-LPx
series module(s) should be wind rated
and approved by the appropriate local and civil codes
prior to installation.
・
Do not expose the back of the module to direct sunlight
・
In Canada installation shall be in accordance with CSA
C22.1, Safety Standard for Electrical Installations,
Canadian Electrical Code, Part 1.
・
When handle the modules,
DO NOT HOLD THEM BY
SUPPORTING ONLY ONE SIDE OF THE LONG
FRAME BECAUSE IT CAN CAUSE SEPARATION OF
THE GLASS AND FRAME.
CAUTION
FIRE RATING
・
In case of roof installation, PV module assembly shall be
mounted on a fire resistant roof covering rated for the
application.
KDxxxGX-LPx
series modules are
comprised of a glass front surface, polyethylene
terephthalate (PET) backsheet with a Class C fire rating.
GROUNDING
・
Refer to “Grounding” section.
BATTERY
・
When PV modules are used to charge batteries, the
battery must be installed in a manner, which will ensure
the performance of the system and the safety of its users.
Follow the battery manufacturer
’
s safety guidelines
concerning installation, operation and maintenance
recommendations
. In general, the battery (or battery
bank) should be kept away from people and animals.
Select a battery site that is protected from sunlight, rain,
snow, debris, and is well ventilated. Most batteries
generate hydrogen gas when charging, which can be
explosive. Do not light matches or create sparks near
the battery bank. When a battery is installed outdoors, it
should be placed in an insulated and ventilated battery
case specifically designed for this purpose.
4. SITE SELECTION
In most applications,
KDxxxGX-LPx
series modules should
be installed in a location where they will receive maximum
sunlight throughout the year. In the Northern Hemisphere,
KD135GX-LPU
~
KD245GX-LPB
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
the modules should typically face south, and in the Southern Hemisphere, the modules should typically face north. Modules facing 30 degrees away from true South (or North) will lose approximately 10 to 15 percent of their power output. If the module faces 60 degrees away from true South (or North), ...
(1)to one of the .35” (9mm) diameter holes marked “ground” using 5/16” stainless steel hardware. Wrap conductor around bolt. Tighten the screws with adequate torque (usually 132 in-lb). Avoid direct contact of copper ground conductor to aluminum frame. (2)to a ground lug (manufacturer:ILSCO,model:GB...
12. SPECIFICATIONS ・ Under certain conditions, a photovoltaic module may produce more voltage and current than reported at Standard Test Conditions (STC). Refer to Section 690 of the National Electrical Code for guidance in series string sizing and choosing overcurrent protection. Kyocera KDxxxGX-LP...