Page 2 - IMPORTANT SAFETY INSTRUCTIONS; SHOCK OR INJURY TO PERSONS; READ AND FOLLOW ALL INSTRUCTIONS; SAVE THESE INSTRUCTIONS
Kohler Co., Kohler WI 106548- CA (9437) 2 IMPORTANT SAFETY INSTRUCTIONS ATTENTION INSTALLER: INSTRUCTIONS PERTAINING TO RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS READ AND FOLLOW ALL INSTRUCTIONS WARNING: When using this unit, always follow basic precautions, including the following: DANGER: ...
Page 3 - TABLE OF CONTENTS
3 106548- CA (9437) Kohler Co., Kohler WI TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS 2 . . . . . . . . INTRODUCTION 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ROUGHING-IN: K-1200-AC, K-1201-AC 5 . . . . . . . . Ordering Information 5 . . . . . . . . . . . . . . . . . . . . . . ...
Page 4 - INTRODUCTION
4 106548- CA (9437) Kohler Co., Kohler WI INTRODUCTION Please read these instructions carefully to familiarizeyourself with the required tools, materials, andinstallation sequences. Follow the sections that pertainto your particular installation. This will aid you in avoidingthe unnecessary expense ...
Page 10 - A. INSTALLER HAZARD NOTIFICATION
10 106548- CA (9437) Kohler Co., Kohler WI 6. PRODUCT NOTICES A. INSTALLER HAZARD NOTIFICATION DANGER: Risk of fire, electric shock, or injuryto persons. Read important safety instructions oninside front cover of these instructions. WARNING: Risk of electrical shock. A licensedelectrician should mak...
Page 11 - PRODUCT REQUIREMENTS; A. SUMMARY OF KEY REQUIREMENTS; B. PLUMBING SPECIFICATIONS
11 106548- CA (9437) Kohler Co., Kohler WI 7. PRODUCT REQUIREMENTS A. SUMMARY OF KEY REQUIREMENTS S Install unit to level subfloor. S Provide properly dimensioned framing. S Bath can be installed in a corner. Recess, penin-sular or sunken installation is also possible. B. PLUMBING SPECIFICATIONS If ...
Page 12 - INSTALLATION REQUIREMENTS; B. MATERIALS REQUIRED
12 106548- CA (9437) Kohler Co., Kohler WI 8. INSTALLATION REQUIREMENTS A. TOOLS REQUIRED S Conventional woodworking tools S Arc pliers or 14” pipe wrench S Rule S Level S Safety shoes S Safety glasses S Square S Screwdriver S Pliers S Utility knife B. MATERIALS REQUIRED S Plumbers putty S Water-res...
Page 13 - B. SUBFLOOR PREPARATION
13 106548- CA (9437) Kohler Co., Kohler WI 9. SITE REQUIREMENTS A. OLD BATH REMOVAL Disconnect the drain at the trap. Remove old wallmaterial. Slip boards under old bath feet to protectfloor and slide old bath out of recess as illustrated. FloorProtectionBoards Old Bath B. SUBFLOOR PREPARATION Check...
Page 14 - D. PLUMBING PREPARATION; BEFORE INSTALLING UNIT; B. PARTIALLY INSTALL BATH DRAIN
14 106548- CA (9437) Kohler Co., Kohler WI 2. Recessed Installation: Suggested studconstruction is illustrated. D. PLUMBING PREPARATION Position plumbing according to roughing-in dimensions.Cap supplies and check for leaks. 10. BEFORE INSTALLING UNIT A. TILING-IN BEAD INSTALLATION Before setting bat...
Page 15 - INSTALL WHIRLPOOL
15 106548- CA (9437) Kohler Co., Kohler WI 11. INSTALL WHIRLPOOL A. WHIRLPOOL SET-IN Choose one of the three recommended options belowthat is best for your particular installation as described in1., 2., or 3. Follow the appropriate instructions. If subfloor is not level, some shimming of the bath an...
Page 16 - B. HEIGHT ADJUSTMENT
16 106548- CA (9437) Kohler Co., Kohler WI B. HEIGHT ADJUSTMENT NOTICE: Steps B. and C. are necessary for makingyour Kohler Whirlpool operate more quietly. If the subfloor is level, no adjustment is necessary;proceed to Step C. If the subfloor is not level, shimbeneath pump bracket (plywood is recom...
Page 17 - ELECTRICAL CONNECTIONS - AIR ACTUATOR VERSIONS; A. IDENTIFY ELECTRICAL REQUIREMENTS
17 106548- CA (9437) Kohler Co., Kohler WI 12. ELECTRICAL CONNECTIONS - AIR ACTUATOR VERSIONS A. IDENTIFY ELECTRICAL REQUIREMENTS The model number is printed on a plate at the pump endof the module. The model number identifies electrical rating. Electricalconnections for each model vary. S K-1201-AC...
Page 19 - E. FIELD WIRING CONTROL BOX
19 106548- CA (9437) Kohler Co., Kohler WI E. FIELD WIRING CONTROL BOX COMPARTMENT - 230 V, 50 HZ WARNING: Risk of electrical shock. Make surethe power has been disconnected beforeperforming the following procedures. Refer toImportant Safety Instructions located on page 2. CAUTION: Risk of electrica...
Page 20 - ELECTRICAL CONNECTIONS - WALL TIMER VERSIONS
20 106548- CA (9437) Kohler Co., Kohler WI 13. ELECTRICAL CONNECTIONS - WALL TIMER VERSIONS A. IDENTIFY ELECTRICAL REQUIREMENTS The model number is printed on a plate at the pump endof the module. The model number identifies electrical rating. Electricalconnections for each model vary. S K-1200-AC, ...
Page 21 - COMPLETE FINISH WALL
21 106548- CA (9437) Kohler Co., Kohler WI 14. WATER TEST WHIRLPOOL & ELECTRONICS Check all electrical connections. Make sure bothconnections to the pump are securely tightened. Fill bath to a level at least 2” above the top of the highestjet. Operate whirlpool for 5 minutes and check all whirlp...
Page 24 - COMPLETE INSTALLATION; INSTALL HANDLES AND SPOUT
24 106548- CA (9437) Kohler Co., Kohler WI 18. COMPLETE INSTALLATION INSTALL HANDLES AND SPOUT After the deck is finished, attach the handles and spoutto complete faucet installation per manufacturer ’sinstructions. 19. CLEAN-UP AFTER INSTALLATION When cleaning up after installation, do not useabras...
Page 25 - CONFIRM PROPER OPERATION; B. OPERATING SEQUENCE
25 106548- CA (9437) Kohler Co., Kohler WI 20. CONFIRM PROPER OPERATION A. START-UP WHIRLPOOL Refer to Important Safety Instructions on page 2before operating this whirlpool. Please perform the following so that the owner maysafely receive the benefits of whirlpool bathing. 1. Rotate jets so they ar...