Page 3 - – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL; WARNING; – TO REDUCE THE RISK OF PERSONAL INJURY IN THE EVENT OF A RANGE
1 IMPORTANT SAFETY INSTRUCTIONS - PLEASE READ THIS SECTION CAREFULLY BEFORE INSTALLATION - WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, OBSERVE THE FOLLOWING: 1) Installation and electrical wiring must be done by qualified professionals and in accordance with all applicab...
Page 4 - CAUTION
2 What to Do In The Event Of a Range Top Grease Fire SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray, and then turn off the burner. KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the flames do not go out immediately, EVACUATE THE AREA AND CALL THE FIRE DEPARTMENT or...
Page 5 - COMPONENTS OF PACKAGE; (Must keep all material for returns or refunds)
3 COMPONENTS OF PACKAGE (Must keep all material for returns or refunds) BOX 1 OF 2 MODEL NO. IS2436GSB MODEL NO. IS2442GSB Glass Canopy w/ LCD Screen – 1 Baffle Filter – 2 Warranty Registration Card – 1 Instructions Manual – 1 * Attac hed to Hood Telescopic Stack – 1 Blower Unit - 1 Inner Duct Cover...
Page 6 - INSTALLATION; PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING; Calculation before Installation; TABLE 1; SAFETY WARNING
4 INSTALLATION PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING Calculation before Installation To calculate installation, please refer to TABLE 1. (All calculation in inches.) TABLE 1 A = Height of Floor to Ceiling B = Height of Floor to Counter Top (Standard: 36”) C = Preferred Height of Counter ...
Page 8 - Route house wiring into the ceiling as close; Ductwork Installation; Use 7” round aluminum or steel pipe (not; Telescopic Stack Installation
6 6. Align the telescopic stack to the pre-drill holes on the ceiling and securely fasten to the joists and cross framing lumber with eight screws (not provided). Make sure screws are driven into center of joists and cross framing lumber for maximum support. 7. Adjust the blower unit to the telescop...
Page 9 - Connection to LCD Screen; Final Assembly
7 11. Slide the inner duct cover up and secure to the telescopic stack with four (ST 3 x 15) screws (provided). Refer to Figure 7. 12. With assistance, slide the outer duct cover to the blower unit and ask assistant to hold steady until step 15 is completed. 13. Attach glass canopy with LCD screen u...
Page 10 - OPERATION INSTRUCTIONS; Figure 9; GENERAL SETUP
8 OPERATION INSTRUCTIONS Figure 9 LCD DISPLAY: PRESS TO TURN ON/OFF THE LCD SCREEN (When power is turned on, LCD screen will light up & remain lit until turn off. When power is turned off, LCD screen will remain lit for several seconds before turning off.) GENERAL SETUP (During menu option, if a...
Page 11 - The screen will indicate:; OR
9 Setting Background Color 1. Press until flashes. 2. Press or to select background color (purple, light blue, or green). Setting Sound 1. Press until flashes. 2. Press to select sound. OR Press to mute sound. (When appears, keypad sound is ON.) HOOD OPERATION Turning Fan ON/OFF 1. Press to turn fan...
Page 13 - MAINTENANCE; The LCD display will indicate
11 MAINTENANCE SAFETY WARNING NEVER PUT YOUR HAND INTO AREA HOUSING THE FAN WHILE THE FAN IS OPERATING. For the optimal level of operation, clean the range hood surface and baffles/filters/oil containers regularly. To Clean Hood Surface CAUTION: NEVER USE ABRASIVE CLEANERS, PADS, OR CLOTHS. *** Regu...
Page 15 - SPECIFICATIONS; 8-Gauge Commercial Grade Stainless Steel
13 SPECIFICATIONS BOX 1 OF 2 MODEL / SIZE IS2436GSB / 36" IS2442GSB / 42” BOX 2 OF 2 MODEL / SIZE IS124DC – Duct cover with blower unit COLOR 18-Gauge Commercial Grade Stainless Steel CONSUMPTION / AMPERE 240W / 2.0A VOLTAGE 120V 60Hz NUMBER OF MOTORS 1 DESIGN 18-Gauge Seamless / Satin Finish FA...
Page 16 - MEASUREMENTS & DIAGRAMS
14 MEASUREMENTS & DIAGRAMS All ( ) measurements are in millimeter. All inch measurements are converted from millimeter. Inch measurements are estimated. ***Mounting Template (Sold Separately)
Page 17 - PARTS LIST
15 PARTS LIST MODEL NO.: IS2436GSB IS2442GSB (Box 1 of 2) (Box 2 of 2) MODEL NO. IS2436GSB MODEL NO. IS2442GSB NO. DESCRIPTION MODEL PART NO. 01 Glass Canopy IS2436GSB GC-0036-01 IS2442GSB GC-0042-01 02 Housing Connector PH-0001-01 03 Sensor Control PH-0002-01 04 Light Support Panel (Top) PH-0003-01...
Page 19 - CIRCUIT DIAGRAM
17 CIRCUIT DIAGRAM MODEL NO.: IS2436GSB IS2442GSB Q L C M H 20W 20W MOTOR 16uF/250V BLUE YELLOW GREY GREEN BLACK RED BROW N WHITE GREEN BLACK 120V 60Hz P R O C E S S O R B O A R D L C D
Page 20 - DISCLAIMER; DAMAGES CAUSED DURING TRANSIT ARE NOT COVERED UNDER OUR WARRANTY.
18 DISCLAIMER 1. CAREFULLY INSPECT ALL ITEMS FOR DAMAGES BEFORE ACCEPTING DELIVERY. NOTE ANY DAMAGES ON THE FREIGHT BILL OR EXPRESS RECEIPT. REQUEST NAME AND SIGNATURE OF THE CARRIER’S AGENT AND KEEP COPY TO SUPPORT YOUR CLAIM. Upon acceptance of items, owner assumes responsibility for its safe arri...
Page 21 - WARRANTY; WARRANTY CERTIFICATE; for failure of light bulbs
19 WARRANTY WARRANTY CERTIFICATE KOBE Range Hoods, Inc. warrants all products manufactured or supplied by it to be free from defects in workmanship and materials. Its obligations pursuant to this warranty are limited to a period of two years from the date of purchase and to the repair or replacement...
Page 23 - PRODUCT REGISTRATION
21 PRODUCT REGISTRATION Register Your Product! Any covered failure occurring within two years of original purchase arising from defective workmanship or material in manufacture will be repaired or at our option, replaced free of charge by an authorized KOBE Range Hoods Agent or KOBE Range Hoods as a...
Page 24 - KOBE Range Hoods
22 KOBE Range Hoods 10505 Valley Blvd Suite # 302 El Monte, CA 91731 USA http://www.KOBERangeHoods.com This KOBE hood is made for use in the USA and CANADA only. We do not recommend using this hood overseas as the power supply may not be compatible and may violate the electrical code of that country...