Page 5 - Preface; About this Manual; Product Contents
Preface About this Manual Thank you for purchasing and using the Intel ® Server System SR1500AL. This manual is written for system technicians who are responsible for troubleshooting, upgrading, and repairing this server system. This document provides reference information, feature information, and ...
Page 6 - Intel
vi Intel ® Server System SR1500AL User’s Guide There are two versions of this server system: the Intel ® Server System SR1500ALSAS (SAS/SATA version) and the Intel ® Server System SR1500AL (SATA only version). The contents of each server system are listed below. Intel ® Server System SR1500ALSAS Con...
Page 9 - Safety Information; Important Safety Instructions; Consignes de sécurité; Instrucciones de seguridad importantes
Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the Intel ® Server Deployment Toolkit 2.0 CD and/or at http://support.intel.com/su...
Page 10 - 在执行任何指令之前,请阅读本文档中的所有注意事项及安全声明。 和/或
x Intel ® Server System SR1500AL User’s Guide 重要安全指导 在执行任何指令之前,请阅读本文档中的所有注意事项及安全声明。 和/或 http://support.intel.com/support/motherboards/server/sb/CS-010770.htm 上的 Intel Server Boards and Server Chassis Safety Information(《Intel 服务器主板与服务器机箱安全信息》)。
Page 11 - Warnings
Intel ® Server System SR1500AL User’s Guide xi Warnings Heed safety instructions: Before working with your server product, whether you are using this guide or any other resource as a reference, pay close attention to the safety instructions. You must adhere to the assembly instructions in this guide...
Page 13 - Table of Contents
Intel ® Server System SR1500AL User’s Guide xiii Table of Contents Preface ......................................................................................................................... v About this Manual ......................................................................................
Page 19 - List of Figures
Intel ® Server System SR1500AL User’s Guide xix List of Figures Figure 1. Intel ® Integrated Server System SR1500AL .............................................................. 3 Figure 2. ChassisComponents ..............................................................................................
Page 21 - List of Tables
Intel ® Server System SR1500AL User’s Guide xxi List of Tables Table 1. Server System References ......................................................................................... 1Table 2. Intel ® Server System SR1500AL Feature Summary ................................................... 4 Ta...
Page 23 - Server System References
1 Server System References If you need more information about this product or information about the accessories that can be used with this server chassis, use the following resources. Table 1. Server System References For this information or software Use this Document or Software For in-depth techni...
Page 25 - Server System Features
2 Server System Features This chapter briefly describes the main features of the server system. This chapter provides illustrations of the product, a list of the server system features, and diagrams showing the location of important components and connections on the server system. Figure 1. Intel ® ...
Page 28 - Chassis Component Identification; Internal Components
6 Intel ® Server System SR1500AL User’s Guide Chassis Component Identification This section helps you identify the components of your server system. If you are near the system, you can also use the Quick Reference Label provided on the inside of the chassis cover to assist in identifying components....
Page 30 - Configuration Jumpers
8 Intel ® Server System SR1500AL User’s Guide Configuration Jumpers Figure 4. BIOS Select Jumper Jumper Name Jumper Purpose BIOS Select If pins 1-2 are jumpered, the BIOS in the lower bank will be selected on the next reset. These pins should be jumpered on 2-3 for normal operation. TP02087 3 BIOS S...
Page 33 - Back Panel Connectors
Intel ® Server System SR1500AL User’s Guide 11 Back Panel Connectors Figure 7. Back Panel Connectors The NIC LEDs at the right and left of each NIC provide the following information. A. Mouse B. Keyboard C. Serial Port B (RJ45) D. NIC 1 (10/100/1000 Mb) E. NIC 2 (10/100/1000 Mb) F. Video G. USB Port...
Page 35 - RAID Support
Intel ® Server System SR1500AL User’s Guide 13 Figure 9. Passive Backplane Components RAID Support The Intel ® Server System SR1500AL provides an embedded SATA controller that supports both 1.5 and 3.0 Gbps data transfer rates. The Intel ® Server System SR1500ALSAS provides SAS and SATA support. Bot...
Page 36 - Front of Server System; Standard Control Panel
14 Intel ® Server System SR1500AL User’s Guide Front of Server System Standard Control Panel The diagram below shows the features available on the standard control panel. Another option is the Intel ® Local Control Panel, which is discussed next. Callout Feature Function A. B. NIC 2 Activity LED NIC...
Page 38 - Bezels
16 Intel ® Server System SR1500AL User’s Guide Figure 11. Intel ® Local Control Panel Bezels The optional front bezels provide a snap-on design that allows for maximum airflow through the server chassis. Two bezels are available. One fits a system that has the standard control panel installed. The o...
Page 39 - Rear of Server System
Intel ® Server System SR1500AL User’s Guide 17 Rear of Server System Figure 12. Server System Back A. PS2 mouse connector H. USB 2 connector B. PCI card bracket (low profile) I. Video connector C. PCI card bracket (full height) J. NIC 1 connector D. AC Power Receptacle K. NIC 2 connector E. Manageme...
Page 40 - Peripheral Devices; Hard Disk Drives
18 Intel ® Server System SR1500AL User’s Guide Peripheral Devices The server system provides locations and hardware for installing hard drives, a USB floppy drive, and an optical drive. The drives must be purchased separately. The following figure shows the available options. . Figure 13. Optional P...
Page 41 - Slimline Optical Drive Carrier; Advanced Management Options; Intel® Remote Management Module
Intel ® Server System SR1500AL User’s Guide 19 Slimline Optical Drive Carrier The slimline optical drive carrier can be used with an optional optical drive. One slimline carrier is included with your server system; the optical drive must be purchased separately. You cannot install both an optical dr...
Page 43 - Before You Begin; Tools and Supplies Needed; Removing and Installing from a Rack; Fixed Bracket Rack Mount Removal
3 Hardware Installations and Upgrades Before You Begin Before working with your server product, pay close attention to the “Safety Information” at the beginning of this manual. Tools and Supplies Needed • Phillips* (cross head) screwdrivers (#1 bit and #2 bit) • Needle nosed pliers • Antistatic wris...
Page 44 - Fixed Bracket Rack Mount Installation
22 Intel ® Server System SR1500AL User’s Guide Fixed Bracket Rack Mount Installation 1. Fully extend a rail assembly; the finger tab for the extension lock is revealed. 2. Press the finger tab and slide the inside rail from the middle rail until it completely separates. Note: The middle rail and out...
Page 45 - Basic Rail Rack Mount Removal
Intel ® Server System SR1500AL User’s Guide 23 22. Fully extend the left and right rails until the extension locks have engaged and the rails will not push back in. The rail system is now ready to receive the chassis. Caution: Lifting and placing the chassis in the rails is a two-person job. If need...
Page 46 - Tool-less Rail Rack Mount Servicing; Removing and Installing the Front Bezel
24 Intel ® Server System SR1500AL User’s Guide 11. Slide the server chassis all the way into the rack. 12. Use the rack screws (#10-32 x 3/4) to secure the chassis and rack handles into the rack. Tool-less Rail Rack Mount Servicing 1. To service the system, pull the system out from the rack. 2. Disc...
Page 47 - Removing the Front Bezel
Intel ® Server System SR1500AL User’s Guide 25 Removing the Front Bezel Use the steps below if your system includes a front bezel. 1. Unlock the bezel. 2. Disconnect any cables attached to the control panel. 3. Pull the bezel from the server system. Figure 16. Removing the Front Bezel TP02199
Page 48 - Installing the Front Bezel; Removing and Installing the System Cover; Removing the System Cover
26 Intel ® Server System SR1500AL User’s Guide Installing the Front Bezel Use the steps below if your system includes either the standard front bezel or the front bezel for the Intel ® Local Control Panel. The front bezel is optional. 1. At each end of the bezel, line up the center notch on the beze...
Page 49 - Installing the System Cover
Intel ® Server System SR1500AL User’s Guide 27 2. Turn off all peripheral devices connected to the server. Turn off the server. 3. Disconnect the AC power cord(s). 4. Remove the safety screw if it is installed. See letter "A" in the figure below. 5. While holding in the blue button at the to...
Page 50 - Removing and Installing the Processor Air Duct; Removing the Processor Air Duct
28 Intel ® Server System SR1500AL User’s Guide Figure 19. Installing the Server System Cover Removing and Installing the Processor Air Duct Always operate your server server system with the processor air duct in place. The air duct is required for proper airflow within the server system. For instruc...
Page 52 - Installing the Processor Air Duct
30 Intel ® Server System SR1500AL User’s Guide Installing the Processor Air Duct 1. Observe the safety and ESD precautions at the beginning of this book. See " “Safety Information” . 2. Power down the server and unplug all peripheral devices and the AC power cable(s). 3. Remove the server system...
Page 53 - Installing and Removing Memory; Installing DIMMs
Intel ® Server System SR1500AL User’s Guide 31 Figure 22. Installing the Processor Air Duct Installing and Removing Memory The silkscreen on the board for the DIMMs displays DIMM A1, DIMM A2, DIMM B1, DIMM B2, DIMM C1, DIMM C2, DIMM D1 and DIMM D2 starting from the center of the board. See "Memo...
Page 55 - Removing DIMMs; Installing or Replacing the Processor; Installing the Processor
Intel ® Server System SR1500AL User’s Guide 33 11. Replace the system's cover and reconnect the AC power cord(s). For instructions on installing the system's cover, see “Installing the System Cover” . Removing DIMMs To remove a DIMM, follow these steps: 1. Observe the safety and ESD precautions in “...
Page 58 - Removing a Processor
36 Intel ® Server System SR1500AL User’s Guide Figure 27. Installing the Heat Sink (2U Passive Heat Sink Shown) 4. Reinstall and reconnect any parts you removed or disconnected to reach the processor sockets. 5. Replace the system's cover and reconnect the AC power cord(s). For instructions on insta...
Page 59 - Removing and Installing the Small Air Baffle
Intel ® Server System SR1500AL User’s Guide 37 9. Raise the CPU load plate. 10. Remove the processor. 11. If installing a replacement processor, see “Installing the Processor” . Otherwise, install the protective socket cover over the empty processor socket and reinstall the system’s cover. Removing ...
Page 60 - Removing the Small Air Baffle; Installing the Small Air Baffle
38 Intel ® Server System SR1500AL User’s Guide Removing the Small Air Baffle 1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” . 2. Power down the server and unplug all peripheral devices and the AC power cable(s). 3. Remove the server system cover. Fo...
Page 61 - Installing and Removing a Hot-swap Hard Drive; Installing a SAS or SATA Hot-swap Hard Disk Drive
Intel ® Server System SR1500AL User’s Guide 39 Figure 29. Installing the Small Air Baffle 3. Install the server system cover. For instructions, see “Installing the System Cover” . 4. Plug all peripheral devices and the AC power cable(s) into the server. Installing and Removing a Hot-swap Hard Drive ...
Page 64 - Removing a SAS or SATA Hot-swap Hard Disk Drive
42 Intel ® Server System SR1500AL User’s Guide Removing a SAS or SATA Hot-swap Hard Disk Drive 1. Remove the front bezel if it is installed. For instructions, see “Removing the Front Bezel” . 2. Press in on the green latch at the front of the hard drive carrier. 3. Pull out on the black lever to sli...
Page 65 - Installing a Slimline Optical Drive or Internal USB Floppy
Intel ® Server System SR1500AL User’s Guide 43 Installing a Slimline Optical Drive or Internal USB Floppy 1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” . 2. Power down the server and unplug all peripheral devices and the AC power cable(s). 3. Remov...
Page 66 - Removing a Slimline Optical Drive or Internal USB Floppy
44 Intel ® Server System SR1500AL User’s Guide Figure 35. Installing an Optical Drive Assembly into the Server System 14. Install the server system cover. For instructions, see “Installing the System Cover” . 15. (Optional) Install the front bezel. For instructions, see “Installing the Front Bezel” ...
Page 68 - Filling Empty Server System Bays
46 Intel ® Server System SR1500AL User’s Guide Figure 37. Removing the Slimline Optical Drive from the Tray Filling Empty Server System Bays A filler panel, drive blank, or empty drive carrier must be installed into an empty drive bay. To access the drive bays, remove the front bezel if it is instal...
Page 69 - Installing and Removing the PCI Riser Assembly; Removing the PCI Riser Assembly
Intel ® Server System SR1500AL User’s Guide 47 Installing and Removing the PCI Riser Assembly Removing the PCI Riser Assembly To remove the PCI riser assembly, use the following instructions. 1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” . 2. Power...
Page 70 - Installing the PCI Riser Assembly
48 Intel ® Server System SR1500AL User’s Guide 8. If you need to add or replace a PCI add-in card, see “Installing and Removing a PCI Add-in Card” . 9. If you need to add or replace a PCI riser connector, see “Replacing a PCI Riser Card” . 10. If you removed the PCI riser assembly for another proced...
Page 71 - Replacing a PCI Riser Card; Removing the PCI Express* Riser Card
Intel ® Server System SR1500AL User’s Guide 49 Replacing a PCI Riser Card Caution: PCI riser connectors are NOT hot swappable. Before removing or replacing the riser connector, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system...
Page 74 - Installing and Removing a PCI Add-in Card; Installing a PCI Add-in Card
52 Intel ® Server System SR1500AL User’s Guide 16. Install the server system cover. For instructions, see “Installing the System Cover” . 17. Plug all peripheral devices and the AC power cable(s) into the server. Installing and Removing a PCI Add-in Card The instructions below describe how to instal...
Page 75 - Removing a PCI Add-in Card
Intel ® Server System SR1500AL User’s Guide 53 10. Install the PCI riser assembly into the server system. For instructions, see “Installing the PCI Riser Assembly” . 11. Install the processor air duct. For instructions, see “Installing the Processor Air Duct” . 12. Install the server system cover. F...
Page 78 - Installing the Intel
56 Intel ® Server System SR1500AL User’s Guide 9. Install the processor air duct. For instructions, see “Installing the Processor Air Duct” . 10. Install the server system cover. For instructions, see “Installing the System Cover” . 11. Plug all peripheral devices and the AC power cable(s) into the ...
Page 79 - Removing the Intel
Intel ® Server System SR1500AL User’s Guide 57 9. Install the PCI riser assembly into the server system. For instructions, see “Installing the PCI Riser Assembly” . 10. Install the processor air duct. For instructions, see “Installing the Processor Air Duct” . 11. Install the server system cover. Fo...
Page 80 - Replacing the Backplane Board; Removing the Backplane Board
58 Intel ® Server System SR1500AL User’s Guide 11. Install the server system cover. For instructions, see “Installing the System Cover” . 12. Plug all peripheral devices and the AC power cable(s) into the server. Replacing the Backplane Board The instructions below describe how to replace the backpl...
Page 81 - Installing the Backplane Board
Intel ® Server System SR1500AL User’s Guide 59 6. Loosen the captive screw on the backplane board (see letter “A” in the figure below). 7. Hold the backplane board only by the edges. Slide the backplane board to the right to release it (see letter “B” in the figure below). 8. Lift the backplane boar...
Page 84 - Installing and Removing the Server Board; Installing the Server Board
62 Intel ® Server System SR1500AL User’s Guide Installing and Removing the Server Board Installing the Server Board 1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” . 2. Power down the server and unplug all peripheral devices and the AC power cable(s)...
Page 85 - Removing the Server Board
Intel ® Server System SR1500AL User’s Guide 63 8. Install the PCI riser assembly. For instructions, see “Installing the PCI Riser Assembly” . 9. Install the processor air duct. For instructions, see “Installing the Processor Air Duct” . 10. Install the server system cover. For instructions, see “Ins...
Page 86 - Replacing the Backup Battery
64 Intel ® Server System SR1500AL User’s Guide 7. Install the replacement server board. For instructions, see “Installing the Server Board” . 8. Install the PCI riser assembly. For instructions, see “Installing the PCI Riser Assembly” . 9. Install the processor air duct. For instructions, see “Insta...
Page 88 - Replacing the Power Supply
66 Intel ® Server System SR1500AL User’s Guide Replacing the Power Supply Caution: The power supply is not hot-swappable. Before removing or replacing the power supply, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pres...
Page 89 - Replacing the Control Panel
Intel ® Server System SR1500AL User’s Guide 67 6. Install the server system cover. For instructions, see “Installing the System Cover” . 7. Plug all peripheral devices and the AC power cable(s) into the server. Replacing the Control Panel The steps for replacing the standard control panel and the In...
Page 91 - Replacing a System Fan
Intel ® Server System SR1500AL User’s Guide 69 Replacing a System Fan Caution: The system fans are NOT hot swappable. Before removing or replacing a fan, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power ...
Page 92 - Installing and Removing the Rack Handles; Installing the Rack Handles
70 Intel ® Server System SR1500AL User’s Guide Figure 60. I Installing a Fan into the Fan Module 7. Install the server system cover. For instructions, see “Installing the System Cover” . 8. Plug all peripheral devices and the AC power cable(s) into the server. Installing and Removing the Rack Handle...
Page 93 - Removing the Rack Handles
Intel ® Server System SR1500AL User’s Guide 71 Figure 61. I Installing the Rack Handle 6. Install the server system cover. For instructions, see “Installing the System Cover” . 7. Install the front bezel. For instructions, see “Installing the Front Bezel” . 8. Plug all peripheral devices and the AC ...
Page 95 - Server Utilities; Using the BIOS Setup Utility; Starting Setup; If You Cannot Access Setup; Setup Menus
4 Server Utilities Using the BIOS Setup Utility This section describes the BIOS Setup Utility options, which is used to change server configuration defaults. You can run BIOS Setup with or without an operating system being present. See “Server System References” for a link to the Intel ® 5000 Series...
Page 97 - Upgrading the BIOS; Preparing for the Upgrade; Recording the Current BIOS Settings
Intel ® Server System SR1500AL User’s Guide 75 Upgrading the BIOS The upgrade utility allows you to upgrade the BIOS in flash memory. The code and data in the upgrade file include the following: • On-board system BIOS, including the recovery code, BIOS Setup Utility, and strings. • On-board video BI...
Page 98 - Obtaining the Upgrade; Clearing the Password
76 Intel ® Server System SR1500AL User’s Guide Obtaining the Upgrade Download the BIOS image file to a temporary folder on your hard drive. See “Server System References” for a link to the update software. Note: Review the instructions and release notes that are provided in the readme file distribut...
Page 101 - Appendix A: Technical Reference; Cable Routing
Appendix A: Technical Reference Cable Routing When you add or remove components from your server system, make sure your cables are routed correctly before reinstalling the server system cover. Use caution to make sure no cables or wires are pinched and that the airflow from the fans is not blocked. ...
Page 102 - SATA Connections
80 Intel ® Server System SR1500AL User’s Guide SATA Connections Use the figure below to determine the proper SATA cabling. Figure 66. Connecting SATA Cables 0 2 1 1 0 2 A A B AF000375
Page 103 - 00W Single Power Supply Input Voltages
Intel ® Server System SR1500AL User’s Guide 81 Figure 67. Cabling Around the Small Air Baffle 600W Single Power Supply Input Voltages • 100-127V at 50/60 Hz; 8.55 A max. • 200-240V at 50/60 Hz; 4.3 A max. AF000376 A B
Page 104 - 00W Single Power Supply Output Voltages
82 Intel ® Server System SR1500AL User’s Guide 600W Single Power Supply Output Voltages The table below lists the total wattage available from the power subsystem for each voltage. Ensure that your loads do not exceed the combined total wattage of 600 Watts. For information about calculating the pow...
Page 105 - System Environmental Specifications
Intel ® Server System SR1500AL User’s Guide 83 System Environmental Specifications Table 6. System Environmental Specifications Temperature Non-operating Operating -40 ° to 70 °C. 10 ° to 35 °C; derated 0.5 °C for every 1000 ft (305 m) to a maximum of 10,000 ft. Humidity Non-operating 90% relative h...
Page 107 - Appendix B: Troubleshooting; Resetting the System
Appendix B: Troubleshooting This chapter helps you identify and solve problems that might occur while you are using the system. For any issue, first ensure you are using the latest firmware and files. Firmware upgrades include updates for BIOS, the Baseboard Management Controller (BMC), and the hot-...
Page 108 - Problems following Initial System Installation; First Steps Checklist
86 Intel ® Server System SR1500AL User’s Guide Problems following Initial System Installation Problems that occur at initial system startup are usually caused by an incorrect installation or configuration. Hardware failure is a less frequent cause. If the problem you are experiencing is with a speci...
Page 109 - Hardware Diagnostic Testing; Verifying Proper Operation of Key System Lights; Confirming Loading of the Operating System
Intel ® Server System SR1500AL User’s Guide 87 Hardware Diagnostic Testing This section provides a more detailed approach to identifying a hardware problem and locating its source. Caution: Turn off devices before disconnecting cables: Before disconnecting any peripheral cables from the system, turn...
Page 110 - Specific Problems and Corrective Actions; Power Light Does Not Light
88 Intel ® Server System SR1500AL User’s Guide Specific Problems and Corrective Actions This section provides possible solutions for these specific problems: • Power light does not light. • No characters appear on screen. • Characters on the screen appear distorted or incorrect. • System cooling fan...
Page 111 - No Characters Appear on Screen
Intel ® Server System SR1500AL User’s Guide 89 No Characters Appear on Screen Check the following: • Is the keyboard functioning? Test it by turning the "Num Lock" function on and off to make sure the Num Lock light is functioning. • Is the video monitor plugged in and turned on? If you are ...
Page 112 - System Cooling Fans Do Not Rotate Properly; Drive Activity Light Does Not Light
90 Intel ® Server System SR1500AL User’s Guide • Does this video monitor work correctly if plugged into a different system? System Cooling Fans Do Not Rotate Properly If the system cooling fans are not operating properly, it is an indication of possible system component failure. Check the following:...
Page 113 - Cannot Connect to a Server; Problems with Network; The server hangs when the drivers are loaded; The add-in adapter stopped working without apparent cause
Intel ® Server System SR1500AL User’s Guide 91 Cannot Connect to a Server • Make sure the network cable is securely attached to the correct connector at the system back panel. • Try a different network cable. • Make sure you are using the correct and the current drivers. See “Server System Reference...
Page 114 - System Boots when Installing PCI Card
92 Intel ® Server System SR1500AL User’s Guide • The network driver files may be corrupt or deleted. Delete and then reinstall the drivers. • Run diagnostics. System Boots when Installing PCI Card System Management features require full-time "standby" power. This means some parts of the syst...
Page 115 - Bootable CD-ROM Disk Is Not Detected
Intel ® Server System SR1500AL User’s Guide 93 • If the problems are intermittent, there may be a loose cable, dirt in the keyboard (if keyboard input is incorrect), a marginal power supply, or other random component failures. • If you suspect that a transient voltage spike, power outage, or brownou...
Page 116 - LED Information; BIOS POST Beep Codes
94 Intel ® Server System SR1500AL User’s Guide LED Information The Intel ® Server Board S5000PAL includes LEDs that can aid in troubleshooting your system. A table of these LEDs with a description of their use is listed below. BIOS POST Beep Codes The table below lists the POST error beep codes. Pri...
Page 119 - Board / Chassis Information
Appendix C: Intel ® Server Issue Report Form Note: An on-line / automatic submission version of this form is available at http:// support.intel.com/support/motherboards/server/chassis/SR1500/. For the fastest service, please submit your form via the Internet. Date Submitted: ________________________...
Page 120 - DIMM Configuration
98 Intel ® Server System SR1500AL User’s Guide DIMM Configuration DIMM A1 MB and Vendor / part number: __________________________________ DIMM A2 MB and Vendor / part number: __________________________________ DIMM B1 MB and Vendor / part number: __________________________________ DIMM B2 MB and Ven...
Page 121 - Hard Drive Information; Control Panel Information
Intel ® Server System SR1500AL User’s Guide 99 Hard Drive Information Management Information On-Board Platform Instrumentation only ___________________________________ Intel ® Remote Management Module _______________________________________ Control Panel Information Standard Control Panel __________...
Page 122 - Complete Problem Description
100 Intel ® Server System SR1500AL User’s Guide Complete Problem Description In the space below, provide a complete description of the steps used to reproduce the problem or a complete description of where the problem can be found. Please also include any details on troubleshooting already done. ___...
Page 123 - Appendix D: LED Decoder
Appendix D: LED Decoder During the system boot process, BIOS executes a number of platform configuration processes, each of which is assigned a specific hex POST code number. As each configuration routine is started, BIOS will display the given POST code to the POST Code Diagnostic LEDs found on the...
Page 129 - Appendix E: Getting Help; World Wide Web; Europe
Appendix E: Getting Help World Wide Web http://support.intel.com/support/motherboards/server/chassis/SR1500. Telephone All calls are billed per incident, levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for te...
Page 130 - In Asia-Pacific region
108 Intel ® Server System SR1500AL User’s Guide In Asia-Pacific region Australia .... 1800 649931 Cambodia .. 63 2 636 9797 (via Philippines) China ......... 800 820 1100 (toll-free) .................... 8 621 33104691 (not toll-free) Hong Kong 852 2 844 4456 India ........... 0006517 2 68303634 (ma...
Page 133 - Product Regulatory Compliance; Product Safety Compliance; Intended Application
Appendix F: Regulatory and Compliance Information Product Regulatory Compliance Warning: To ensure regulatory compliance, you must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated...
Page 134 - Product EMC Compliance - Class A Compliance
112 Intel ® Server System SR1500AL User’s Guide • CB Certificate & Report, IEC60950 (report to include all country national deviations) • GS License (Germany) • GOST R 50377-92 - License (Russia) • Belarus License (Belarus) • Ukraine License (Ukraine) • CE - Low Voltage Directive 73/23/EEE (Euro...
Page 135 - Certifications / Registrations / Declarations; Product Regulatory Compliance Markings
Intel ® Server System SR1500AL User’s Guide 113 Certifications / Registrations / Declarations • UL Certification (US/Canada) • CE Declaration of Conformity (CENELEC Europe) • FCC/ICES-003 Class A Attestation (USA/Canada) • VCCI Certification (Japan) • C-Tick Declaration of Conformity (Australia) • M...
Page 137 - Electromagnetic Compatibility Notices
Intel ® Server System SR1500AL User’s Guide 115 Electromagnetic Compatibility Notices FCC Verification Statement (USA) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device mus...
Page 139 - Regulated Specified Components
Intel ® Server System SR1500AL User’s Guide 117 Korean Compliance (RRL) Following is the RRL certification information for Korea. English translation of the notice above: 1. Type of Equipment (Model Name): On License and Product 2. Certification No.: On RRL certificate. Obtain certificate from local...
Page 141 - Extent of Limited Warranty
Appendix G: Warranty Limited Warranty for Intel® Chassis Subassembly Products Intel warrants that the Products (defined herein as the Intel® chassis subassembly and all of its various components and software delivered with or as part of the Products) to be delivered hereunder, if properly used and i...
Page 142 - Warranty Limitations and Exclusions; Limitations of Liability; How to Obtain Warranty Service
120 Intel ® Server System SR1500AL User’s Guide This Limited Warranty does not cover damages due to external causes, including accident, problems with electrical power, usage not in accordance with product instructions, misuse, neglect, alteration, repair, improper installation, or improper testing....
Page 143 - Telephone Support; Returning a Defective Product
Intel ® Server System SR1500AL User’s Guide 121 • North America and Latin America To obtain warranty repair for the product, please go to the following Web site to obtain instructions: http://support.intel.com/support/motherboards/draform.htm • In Europe and in Asia Contact your original authorized ...
Page 145 - Safety Instructions; English
Intel ® Server System SR1500AL User’s Guide 123 Appendix H: Installation/Assembly Safety Instructions English The power supply in this product contains no user-serviceable parts. Refer servicing only to qualified personnel. Do not attempt to modify or use the supplied AC power cord if it is not the ...
Page 147 - Deutsch
Intel ® Server System SR1500AL User’s Guide 125 Deutsch Benutzer können am Netzgerät dieses Produkts keine Reparaturen vornehmen. Das Produkt enthält möglicherweise mehrere Netzgeräte. Wartungsarbeiten müssen von qualifizierten Technikern ausgeführt werden. Versuchen Sie nicht, das mitgelieferte Net...
Page 149 - Français
Intel ® Server System SR1500AL User’s Guide 127 Français Das System wurde für den Betrieb in einer normalen Büroumgebung entwickelt. Der Standort sollte: • "sauber und staubfrei sein (Hausstaub ausgenommen); • "gut gelüftet und keinen Heizquellen ausgesetzt sein (einschließlich direkter Sonn...
Page 151 - Español
Intel ® Server System SR1500AL User’s Guide 129 Español Danger d'explosion si la batterie n'est pas remontée correctement. Remplacer uniquement avec une batterie du même type ou d'un type équivalent recommandé par le fabricant. Disposez des piles usées selon les instructions du fabricant. Le système...
Page 153 - Chinese
Intel ® Server System SR1500AL User’s Guide 131 Chinese Si el sistema ha estado en funcionamiento, el microprocesador y el disipador de calor pueden estar aún calientes. También conviene tener en cuenta que en el chasis o en el tablero puede haber piezas cortantes o punzantes. Por ello, se recomiend...
Page 154 - Italiano
132 Intel ® Server System SR1500AL User’s Guide Italiano Rivolgersi ad un tecnico specializzato per la riparazione dei componenti dell'alimentazione di questo prodotto. È possibile che il prodotto disponga di più fonti di alimentazione. Non modificare o utilizzare il cavo di alimentazione in c.a. fo...
Page 157 - Server Safety Information; Safety Warnings and Cautions
Intel ® Server System SR1500AL User’s Guide 135 Appendix I: Safety Information English Server Safety Information This document applies to Intel ® server boards, Intel ® server chassis (pedestal and rack- mount) and installed peripherals. To reduce the risk of bodily injury, electrical shock, fire, a...
Page 158 - Intended Application Uses; Equipment Handling Practices
136 Intel ® Server System SR1500AL User’s Guide Intended Application Uses This product was evaluated as Information Technology Equipment (ITE), which may be installed in offices, schools, computer rooms, and similar commercial type locations. The suitability of this product for other product categor...
Page 159 - Power and Electrical Warnings; Power Cord Warnings
Intel ® Server System SR1500AL User’s Guide 137 Power and Electrical Warnings Caution: The power button, indicated by the stand-by power marking, DOES NOT completely turn off the system AC power, 5V standby power is active whenever the system is plugged in. To remove power from system, you must unpl...
Page 160 - System Access Warnings; Rack Mount Warnings
138 Intel ® Server System SR1500AL User’s Guide System Access Warnings Caution: To avoid personal injury or property damage, the following safety instructions apply whenever accessing the inside of the product: • Turn off all peripheral devices connected to this product. • Turn off the system by pre...
Page 161 - Other Hazards; Battery Replacement; Cooling and Airflow
Intel ® Server System SR1500AL User’s Guide 139 Electrostatic Discharge (ESD) Caution: ESD can damage disk drives, boards, and other parts. We recommend that you perform all procedures at an ESD workstation. If one is not available, provide some ESD protection by wearing an antistatic wrist strap at...
Page 162 - Sicherheitshinweise für den Server; Sicherheitshinweise und Vorsichtsmaßnahmen
140 Intel ® Server System SR1500AL User’s Guide Deutsch Sicherheitshinweise für den Server Das vorliegende Dokument bezieht sich auf Intel ® Serverplatinen, Intel ® Servergehäuse (Standfuß und Rack) sowie installierte Peripheriegeräte. Es enthält Warnungen und Vorsichtsmaßnahmen zur Vermeidung von G...
Page 163 - Zielbenutzer der Anwendung; Handhabung von Geräten
Intel ® Server System SR1500AL User’s Guide 141 Zielbenutzer der Anwendung Dieses Produkt wurde in seiner Eigenschaft als IT-Gerät getestet, das in Büros, Schulen, Computerräumen und ähnlichen öffentlichen Räumlichkeiten installiert werden kann. Die Eignung dieses Produkts für andere Einsatzbereiche...
Page 164 - Warnungen zu Netzspannung und Elektrizität; Hinweis für Netzkabel
142 Intel ® Server System SR1500AL User’s Guide Warnungen zu Netzspannung und Elektrizität Caution: Durch Betätigen der mit dem Standby-Symbol gekennzeichneten Netztaste wird das System NICHT vollständig vom Netz getrennt. Es sind weiterhin 5 V aktiv, solange das System eingesteckt ist. Um das Syste...
Page 165 - Warnhinweise für den Systemzugang; Warnhinweise für Racks
Intel ® Server System SR1500AL User’s Guide 143 Warnhinweise für den Systemzugang Caution: Um Verletzungen und Beschädigungen zu vermeiden, sollten Sie vor Arbeiten im Produktinneren folgende Sicherheitsanweisungen beachten: • Schalten Sie alle am Produkt angeschlossenen Peripheriegeräte aus. • Scha...
Page 166 - Andere Gefahren; Batterieaustausch; Kühlung und Luftstrom
144 Intel ® Server System SR1500AL User’s Guide Sie müssen für die gesamte Rack-Einheit einen Netztrennschalter einrichten. Dieser Netztrennschalter muß leicht zugänglich sein und über eine Kennzeichnung verfügen, die besagt, daß er die Stromzufuhr zur gesamten Einheit steuert und nicht nur zu den S...
Page 167 - Consignes de securite sur le serveur; Séurité: avertissements et mises en garde
Intel ® Server System SR1500AL User’s Guide 145 • Prüfen Sie, ob Kabel, Erweiterungskarten sowie weitere Komponenten ordnungsgemäß angebracht sind. • Befestigen Sie die Abdeckungen am Gehäuse des Produkts, wie in dessen Anleitung beschrieben. Laser-Peripheriegeräte oder -Komponenten Caution: Beachte...
Page 168 - Domaines d’utilisation prévus
146 Intel ® Server System SR1500AL User’s Guide Domaines d’utilisation prévus Ce produit a été testé comme équipement informatique (ITE) et peut être installé dans des bureaux, des écoles, des salles informatiques et des endroits commerciaux similaires. L’utilisation du présent produit dans des caté...
Page 169 - Pratiques de manipulation de l’équipement; Alimentation et avertissements en matiére d’électricité
Intel ® Server System SR1500AL User’s Guide 147 • Dans les régions sujettes aux orages magnétiques, nous vous recommandons de brancher votre système à un suppresseur de surtension et de déconnecter les lignes de télécommunication de votre modem pendant les orages. • Équipé d’une prise murale reliée ...
Page 170 - Avertissements sur le cordon d’alimentation
148 Intel ® Server System SR1500AL User’s Guide niveaux dangereux de tension, de courant et d’énergie. Renvoyez-le au fabricant en cas de problème. Lorsque vous remplacez un bloc d’alimentation à chaud, débranchez le cordon du bloc d’alimentation en cours de remplacement avant de le retirer du serve...
Page 171 - Avertissements sur le montage en rack
Intel ® Server System SR1500AL User’s Guide 149 • Mettez toutes les vis ou autres attaches de côté lorsque vous retirez les panneaux d’accès. Une fois que vous avez terminé d’accéder à l’intérieur du produit, refixez le panneau d’accès avec les vis ou attaches d’origine. • N’essayez pas d’accéder à ...
Page 172 - Autres risques; Remplacement de la pile; Refroidissement et ventilation
150 Intel ® Server System SR1500AL User’s Guide Décharges électrostatiques (ESD) Attention: Les décharges électrostatiques (ESD) peuvent endommager les lecteurs de disque dur, les cartes et d’autres pièces. Il est fortement conseillé d’effectuer l’ensemble des procédures décrites à un poste de trava...
Page 173 - Périphériques laser; Información de seguridad del servidor
Intel ® Server System SR1500AL User’s Guide 151 Périphériques laser Attention: Pour éviter tout risque d’exposition aux rayonnements et/ou de dommage personnel: • N’ouvrez pas l’enceinte d’un périphérique laser. • Les périphériques laser ne sont pas réparables par l’utilisateur. • Retournez-les au f...
Page 174 - Aplicaciones y usos previstos
152 Intel ® Server System SR1500AL User’s Guide Aplicaciones y usos previstos Este producto ha sido evaluado como equipo de tecnología informática (ITE) que puede instalarse en oficinas, escuelas, salas de equipos informáticos o lugares de ámbito comercial similares. Es posible que sea necesario lle...
Page 175 - Manipulacién del equipo; Advertencias de alimentacién y eléctricas
Intel ® Server System SR1500AL User’s Guide 153 Manipulacién del equipo Reduzca el riesgo de daños personales o en el equipo: • Respete los requisitos de sanidad y seguridad laborales de su país cuando traslade y levante el equipo. • Utilice medios mecánicos u otros que sean adecuados al trasladar o...
Page 176 - Advertencias el acceso al sistema
154 Intel ® Server System SR1500AL User’s Guide Precaución: Para evitar descargas eléctricas o fuego, revise los cables de alimentación que usará con el producto tal y como se describe a continuación: • No intente modificar ni utilizar los cables de alimentación de CA si no son exactamente del model...
Page 177 - Advertencias sobre el montaje en bastidor
Intel ® Server System SR1500AL User’s Guide 155 • Al reemplazar una fuente de alimentación de conexión en funcionamiento, desenchufe el cable de alimentación de la fuente de alimentación que va a reemplazar antes de extraerla del servidor. Precaución: Si el servidor se ha estado ejecutando, los proc...
Page 178 - Otros riesgos; Sustitución de la batería; Enfriamiento y circulación de aire
156 Intel ® Server System SR1500AL User’s Guide disponible, protéjase de alguna forma contras las descargas llevando un brazalete antiestático conectado a la toma de tierra de la carcasa (cualquier superficie de metal que no esté pintada) del servidor cuando manipule las piezas. Manipule siempre las...
Page 179 - Periféricos o dispositivos láser
Intel ® Server System SR1500AL User’s Guide 157 Periféricos o dispositivos láser Precaución Para evitar el riesgo de la exposición a radiaciones o de daños personales: • No abra la caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usu...