Page 2 - Table of Content
2 GS-SR195V Rack Mount Server Table of Content Safety, Care and Regulatory Information ................................................ 4Introduction .............................................................................................. 8Contents Packages .......................................
Page 4 - Safety, Care and Regulatory Information; Important safety information; Observe the following precautions for laser devices:
4 GS-SR195V Rack Mount Server Safety, Care and Regulatory Information Important safety information Read and follow all instructions marked on the product and in the documentation before you operate your system. Retain all safety and operating instructions for future use.* The product should be opera...
Page 5 - Safety Information; Federal Communications Commission (FCC) Statement
5 Safety Information * To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord.* Do not plug a modem or telephone cable into the network interface controller (NIC) receptacle.* Disconnect the modem cable before opening a product enclosure, touching or installing intern...
Page 6 - Canadian Department of Communications Compliance Statement
6 GS-SR195V Rack Mount Server Your telephone company may make changes in its facilities, equipment, operations, or procedures thatcould affect proper operation of your equipment. If they do, you will be notified in advance to give you anopportunity to maintain uninterrupted telephone service.The FCC...
Page 7 - CAUTION
7 Safety Information NOTICE: The Load Number (LN) assigned to each terminal device denotes the percentage of the totalload to be connected to a telephone loop which is used by the device, to prevent overloading. Thetermination on a loop may consist of any combination of devices subject only to the r...
Page 8 - Introduction
8 GS-SR195V Rack Mount Server ; Chassis ; GA-9IVDPC Motherboard (Installed) ; Power Supply (Installed) ; GC-REIU (PCI-E Riser Card) ; FAN Duct x 1 ; CPU Heat Sink x 2 ; Silm type CD-ROM drive (Installed) ; Cables (RJ45) ; GS-SR195V System Installation Guide ; Case Handle Kit x 2 ; Driver CD for moth...
Page 9 - Chapter 1 Features Summary
9 Feature Summary Motherboard GA-9IVDPC Processor Supported Dual socket 604 for Intel ® Xeon(Nocona/Irwindale) processor suopprts 3.6 GB and upperIntel ® Xeon (Nocona/Irwindale) CPUs supports 800 MHz FSB 2nd cache depend on CPU Chipset Intel ® E7320 Chipset Intel ® 6300ESB System Memory:Memory Capac...
Page 10 - Front Panel
1 0 GS-SR195V Rack Mount Server SCSI Controller:Controller Adaptec AIC- 7901X chipset RAID Supported Supports Host RAID RAID 0, 1 and 10 data protection Features Mirroring supports automatic background rebuildsFeatures LBA and Extended Interrupt 13 drive translation incontroller onboard BIOS ZCR Sup...
Page 11 - Safety Regulations
1 1 GS-SR195V Rack Mount Server Server Management Functions:BMC Chip NS IPMI 1.5 controller Failure Detection IPMI 1.5 specification of Server management Event Logging 32KB Nonvolatile Memory to Log System Failure Events Remote Management Follow the IPMI 1.5 specification of Server management Enviro...
Page 12 - Step 2-1: Chassis Removal and Installation; Step 3 Reverse Step 1, and 2 to replace the chassis cover.; Chapter 2 System Hardware Installation; Screw
1 2 GS-SR195V Rack Mount Server Please observe the safety information in chapter “Important Safety Information”Do not expose the server to extreme environmental conditions. Protect it from dust,humidity, and heat. Step 2-1: Chassis Removal and Installation Step 1 Loosen thscrew from the top cover.St...
Page 13 - Pin1 indicator
1 3 Hardware Installation Process Step 2-2: CPU Installation Please make sure the CPU type and speed that are supported by the motherboard. Step 1 Step 2 Step 1 Raise the locking bar on the socket.Step 2 Aligning the pins of the processor with the socket, insert the processor into the socket.Step 3 ...
Page 14 - remember to apply the thermal conductivity compound on the CPU.
1 4 GS-SR195V Rack Mount Server Step 2-3: Heat Sink Installation Step 1 Place the Heat Sink on the CPU. Before putting the heat sink on the CPU, please well remember to apply the thermal conductivity compound on the CPU. Step 2 Seat the heat sink with the four screws. Installation completed. Step 2-...
Page 15 - Step 2-5: PCI Expansion Card Installation; the card firmly seats.
1 5 Hardware Installation Process Step 2-5: PCI Expansion Card Installation GS-SR195V provides expansion riser slot for one PCI-X 64/66MHz slot; and one with PCI-E x8 and x4 slots. To install the peripheral, please go through the following steps. Note: Before installing the PCI expansion card, pleas...
Page 16 - Release button; Step 2-7: FAN Duct Removal and Installation; locked position and push down the screw-holders.
1 6 GS-SR195V Rack Mount Server Step 2-6: Hard Disk Drive Installation Step 1 Press the release button and pull the blank out of the drive bay.Step 2 Remove the hard disk blank. Slide hard disk into blank and secure it with screws.Step 3 Slide the drive into the cage until it clicks, locking the dri...
Page 18 - Chapter 3 Appearance of GS-SR195V; il
1 8 GS-SR195V Rack Mount Server 3-1: Front View of GS-SR195V Chapter 3 Appearance of GS-SR195V M O R - D C e p y T m il S r o t c e n n o C B S U s D E L s D D H I S C S p a w s t o H
Page 19 - System Appearance; lif
System Appearance 1 9 3-2: Rear View of GS-SR195V s r o t c e n n o C 2 / S P s r o t c e n n o C B S U ) 5 4 J R ( tr o P 1 N A L ) 5 4 J R ( tr o P 2 N A L tr o P M O C tr o P A G V t o l S r e s i R e lif o r P - w o L d e ti m i L t o l S r e s i R t h g i e H -l l u F d r o c r e w o P
Page 20 - -3: Switch and LED Indicators Introduction
2 0 GS-SR195V Rack Mount Server 3-3: Switch and LED Indicators Introduction Power NMI LAN1/2 Activities ID BTN&LED NamePower SYS(System) HDD LAN1Activity LAN2Activity ID(Identification) System Event LED HDD Reset Color Condition Description Green On Power On Green Blink Sleep (S1) -- Off Power O...
Page 22 - ir
2 2 GS-SR195V Rack Mount Server 3-5 : Connector Icon Description n o c I t s e g g u S n o it p ir c s e D d r a o b y e K A G V e s u o M N A L t r o P l a i r e S B S U
Page 23 - Motherboard Layout; Chapter 4 Motherboard Layout & Jumper Setting
2 3 Motherboard Layout 4-1: GA-9IVDPC Motherboard Layout Chapter 4 Motherboard Layout & Jumper Setting 1 COM2 7 1 7 1 7 1 1 PC I-E_ 1 BAT 1 DDR -A 1/ 11 SM 1- 2111 84 -1 0R EC4 C11 0 C11 9 DDR -B 1 DDR -A 2 DDR -B 2 C1 33 C11 2 DDR -B 3 DDR -A 4 2 1 DDR -B 4 A B C D E F H G S I J K L M N O P Q R...
Page 26 - You may clear the CMOS data to its default values by this jumper.
2 6 GS-SR195V Rack Mount Server 1 COM2 7 1 7 1 7 1 1 PC I-E_ 1 BAT 1 DDR -A 1/ 11 SM 1- 2111 84 -1 0R E C 4 C11 0 C11 9 DDR -B 1 DDR -A 2 DDR -B 2 C1 33 C11 2 DDR -B 3 DDR -A 4 2 1 DDR -B 4 4-3: Jumper Setting CLR_CMOS ( (Clear CMOS Function) You may clear the CMOS data to its default values by this...
Page 28 - ENTERING SETUP; Chapter 5 BIOS Setup
2 8 GS-SR195V Rack Mount Server < Ç > Move to previous item < È > Move to next item < Å > Move to the item in the left hand < Æ > Move to the item in the right hand <Esc> Main Menu - Quit and not save changes into CMOS Status Page Setup Menu andOption Page Setup Menu - ...
Page 31 - BIOS Setup; Enable this function to max imize the IDE data transfer rate.; This field shows the information of Teansfer Mode.
3 1 BIOS Setup IDE Channel 0 Master, Slave / Channel 1 Master, Slave, Serial ATA The category identifies the types of hard disk from drive C to F that has been installed in the computer. There are two types: auto type, and manual type. Manual type is user-definable; Auto type which willautomatically...
Page 32 - System Information
3 2 GS-SR195V Rack Mount Server System Information This category includes the information of Processor Type, Speed, Extended memory, BIOS Version, BIOS Date, System Product Name, System serial number, System version, System UUID, Main BoardID, and Main Board Serial number.
Page 33 - About This Section: Advanced
3 3 BIOS Setup Figure 2: Advanced Advanced About This Section: Advanced With this section, allowing user to configure your system for basic operation. User can change theprocessor options, chipset configuration, PCI configuration and chipset control. PhoenixBIOS Setup Utility Main Advanced Security ...
Page 34 - PCI Configuration; Embedded Video Controller
3 4 GS-SR195V Rack Mount Server PCI Configuration Figure 2-1: PCI Configuration Embedded Video Controller Onboard VGA Control Enabled Enable onboard VGA device. (Default value) Disabled Disable this function. Embedded SCSI Controller Option ROM Scan Enabled Enableing this item to initialize device e...
Page 36 - Advanced Chipset Control; USB Controller
3 6 GS-SR195V Rack Mount Server Advanced Chipset Control Figure 2-2: Advanced Chipset Control USB Controller This item allows users to enable or disable the USB device by setting item to the desired value. Enabled Enable USB controller. (Default value) Options Disbale this function. Legacy USB Suppo...
Page 38 - Memory Frequency
3 8 GS-SR195V Rack Mount Server Memory Frequency Determine the specifiy memory frequency. 266MHz Select 266MHz as memory frequecncy for system. 333MHz Select 333MHz as memory frequecncy for system. Auto Auto determine memory frequency for system.(Default values) Wake On LAN This option allow user to...
Page 39 - Advanced Processor Option; Hyper Threading Technology
3 9 BIOS Setup Advanced Processor Option Figure 2-3: Advanced Processor Option Hyper Threading Technology Enabled Enables Hyper-Threading Technology Feature when using WindowsXP operating systems that are optimized for Hyper-Threadingtechnology. (Default value) Disabled Disables Hyper-Threading Tech...
Page 40 - Thermal Managerment 2; Adjacent Cache Line Prefetch; NX Protection
4 0 GS-SR195V Rack Mount Server Thermal Managerment 2 Select between TM1 and TM2. Enabled Select Thermal Management 2 function. Disabled Disable this function. (Default value) Adjacent Cache Line Prefetch Enabled Processor will fetch both cache lines when it requires data that is notcurrently inits ...
Page 41 - Peripheral Configuration; Serial Port A; This allows users to configure serial prot A by using this option.
4 1 BIOS Setup Peripheral Configuration PhoenixBIOS Setup Utility Peripheral Configuration Item Specific Help Serial Port A [Enabled] Base I/O address/IRQ [3F8/IRQ4] Serial Port B [Enabled] Base I/O address/IRQ [2F8/IRQ3] Floppy disk controller [Enabled] Floppy Check [Enabled] Parallel ATA [Both] Se...
Page 42 - Serial Port B
4 2 GS-SR195V Rack Mount Server Serial Port B This allows users to configure serial prot B by using this option. Disabled Disable the configuration. Enabled Enable the configuration (Default value) Base I/O Address/IRQ 3F8/IRQ4 Set IO address to 3F8. 2F8/IRQ3 Set IO address to 2F8. (Default value) 3...
Page 44 - Extended Memory Testing
4 4 GS-SR195V Rack Mount Server Extended Memory Testing Determine which type of tests will be performed extended memory. (above 1M) Enabled Enable Extended Memory Testing. (Default value) Disabled Disable this function. Network Server Enabled System will be secured at boot to prevent tampering durin...
Page 45 - Hardware Monitor
4 5 BIOS Setup Hardware Monitor Figure 2-5: Hardware Monitor CPU 1&2/ System/ W83792d 1/2/3 Temperature Display the current CPU1/2 temperature, System, and W83792d 1/2/3 ambient temperature. Voltage: VCORE 1&2/ 3.3V/ +12V / 1.5V / 2.5V Detect system's voltage status automatically. FAN (RPM) ...
Page 46 - About This Section: Security
4 6 GS-SR195V Rack Mount Server Security Figure 3: Security * ** ** About This Section: Security In this section, user can set either supervisor or user passwords, or both for different level of password securities. In addition, user also can set the virus protection for boot sector. Set Supervisor ...
Page 47 - Set User Password; Password entering will be required when system on boot.; Requries entering password when system on boot.
4 7 BIOS Setup Set User Password You can only enter but do not have the right to change the options of the setup menus. Whenyou select this function, the following message will appear at the center of the screen to assistyou in creating a password.Type the password up to 6 characters in lengh and pr...
Page 48 - Console Redirection
4 8 GS-SR195V Rack Mount Server Server Figure 4: Server PhoenixBIOS Setup Utility Main Advanced Security Server Boot Exit Console Redirection Item Specific Help Halt On [Mid] Clear Mem. ECC Error Info. [Disabled] Fatal A on port A [Enabled] F1: Help K L : Select Item + -: Change Values F5: Setup Def...
Page 49 - Console Type
4 9 BIOS Setup Com Port Address If this option is set to enabled, it will use a port on the motherboard. On-board COMA Use COMA as he COM port address. On-board COMB Use COMB as he COM port address. Disabled Disable this function. (Default value) Baud Rate This option allows user to set the specifie...
Page 51 - About This Section: Boot
5 1 BIOS Setup Boot * ** ** About This Section: Boot The “Boot” menu allows user to select among four possible types of boot devices listed using the up and down arrow keys. By applying <+> and <Space> key, you can promote devices and by using the <-> key, you can demote devices. P...
Page 52 - About This Section: Exit
5 2 GS-SR195V Rack Mount Server Exit Figure 6: Exit * ** ** About This Section: Exit Once you have changed all of the set values in the BIOS setup, you should save your chnages and exit BIOS setup program. Select “Exit” from the menu bar, to display the following sub-menu. Exit Saving Changes Exit D...
Page 53 - Exit Saving Changes
5 3 BIOS Setup Exit Saving Changes This option allows user to exit system setup with saving the changes.Press <Enter> on this item to ask for the following confirmation message:Pressing ‘Y’ to store all the present setting values tha user made in this time into CMOS.Therefore, whenyou boot up ...
Page 54 - Discard Changes
5 4 GS-SR195V Rack Mount Server Discard Changes This option allows user to load previos values from CMOS for all setup item.When you press <Enter> on this item, you will get a confirmation dialog box with a messageas below: Save Changes This option allows user to save setup dat ato CMOS.When y...
Page 55 - Chapter 6 Appendix
Appexdix 5 5 Acronyms Meaning ACPI Advanced Configuration and Power Interface A P M Advanced Power Management AGP Accelerated Graphics Port AMR Audio Modem Riser ACR Advanced Communications Riser BBS BIOS Boot Specification BIOS Basic Input / Output System C P U Central Processing Unit C M O S Compl...