Page 3 - Features and Benefits; In the Box; Before Installation
Page 3 of 21 2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:28 AM About Micro On/Off Features and Benefits - Wires in behind existing wall switch or outlet or in a fixture box (requires neutral wire) - Compatible with latching, single momentary and dual momentary switches - Sense wires allow local co...
Page 4 - Identify Switch Type
Page 4 of 21 2443-222/2443-422/2443-522 - Rev: 1/21/2014 8:28 AM Identifying the Electrical Wires in Your Home (North America only) - Line: usually black (may also be called hot, live or power), carries 120VAC electricity into the wall box - Neutral: usually white or white wire bundle, commonly dais...
Page 5 - Installation
Page 5 of 21 2443-222/2443-422/2443-522 - Rev: 1/21/2014 8:28 AM Installation 1) Write down the INSTEON ID found on the back of the unit (XX.XX.XX) 2) Turn off breaker/fuse and verify that the power is off 3) Disconnect wires from existing switch, fixture or outlet and prep all wires to be connected...
Page 6 - Switch Operation Mode; Change to Single Momentary Mode
Page 6 of 21 2443-222/2443-422/2443-522 - Rev: 1/21/2014 8:28 AM d) Perform the step that applies • For single momentary: slowly tap set button four times LED will continue blinking green • For dual momentary: slowly tap set button five times LED will start double-blinking green • To switch back to ...
Page 7 - Local Control Operation
Page 7 of 21 2443-222/2443-422/2443-522 - Rev: 1/21/2014 8:28 AM 3) Press and hold Set button until it beeps a third time LED will start blinking green 4) Slowly tap Set button six times LED will continue blinking green 5) Press and hold Set button until it double-beeps LED will stop blinking 6) Tes...
Page 8 - Adjust Local Settings; Error Blink
Page 8 of 21 2443-222/2443-422/2443-522 - Rev: 1/21/2014 8:28 AM Single Momentary Switch Dual Momentary Switch Adjust Local Settings Change LED Brightness (or turn it off) Default = 50% brightness level 1) Press and hold Set button until it beeps LED will start blinking green 2) Press and hold Set b...
Page 9 - INSTEON Setup; controller
Page 9 of 21 2443-222/2443-422/2443-522 - Rev: 1/21/2014 8:28 AM Blink on Traffic Default = disabled This setting is only adjustable via software or a central controller. Micro module LED will blink red if it detects noise that could disrupt communication. Beep on Button Press Default = disabled Thi...
Page 10 - Make Micro Module a Controller (Set button)
Page 10 of 21 2443-222/2443-422/2443-522 - Rev: 1/21/2014 8:28 AM Controller LED will start blinking You will have four minutes to complete the next steps before linking mode times out 2) Adjust load connected to Micro module to desired brightness level (even off) 3) Press and hold Micro module Set ...
Page 13 - Add X10 Address; Remove X10 Address
Page 13 of 21 2443-222/2443-422/2443-522 - Rev: 1/21/2014 8:28 AM 6) After beep stops, release Micro module Set button After a few seconds, the LED will flash white Micro module will double-beep and the load will turn on X10 Setup Micro module ships with no X10 address assigned. Add X10 Address 1) P...
Page 14 - Specifications
Page 14 of 21 2443-222/2443-422/2443-522 - Rev: 1/21/2014 8:28 AM Specifications General Product name Micro On/Off Brand/manufacturer INSTEON Manufacturer product number 2443-222 (US) 2443-422 (EU) 2443-522 (AUS/NZ) UPC 813922012736 (US) 813922012743 (EU) 813922012750 (AUS/NZ) Warranty 2 years, limi...
Page 17 - Troubleshooting; Problem
Page 17 of 21 2443-222/2443-422/2443-522 - Rev: 1/21/2014 8:28 AM Troubleshooting Problem Possible Cause Solution The LEDs on Micro module are not turning on at all Micro module is not getting power Make sure the circuit breaker is turned on Check junction box wires to ensure all connections are tig...
Page 18 - Stuck/Disabled Button
Page 18 of 21 2443-222/2443-422/2443-522 - Rev: 1/21/2014 8:28 AM respond to X10 address A1 upon install an X10 Address Micro module is locked up A surge or excessive noise on the power line occurred Power cycle Micro module Perform a factory reset Micro module blinks green one time after it is acti...
Page 19 - Phase Bridge Detect Beacon/RF Range Test
Page 19 of 21 2443-222/2443-422/2443-522 - Rev: 1/21/2014 8:28 AM Phase Bridge Detect Beacon/RF Range Test Micro module automatically bridges the electrical phases in your home (via communications with other dual-band devices on the “other phase”). This is only important in 2-phase homes with powerl...
Page 20 - Certification and Warranty
Page 20 of 21 2443-222/2443-422/2443-522 - Rev: 1/21/2014 8:28 AM Certification and Warranty Certification This product has been thoroughly tested by ITS ETL SEMKO, a nationally recognized independent third-party testing laboratory. The North American ETL Listed mark signifies that the device has be...