08 February, 2000
Introduction
This document defines the supported HP NetServer LPr configurations with the XP256 and Microsoft
Cluster Server. These configurations minimize single points of failure (SPOF), provide maximum
availability, and have been certified by Hewlett-Packard or Microsoft. This guide is prescriptive; it
describes the configurations supported by HP. Any deviance to these configurations can result in an
inoperative cluster or an operating cluster with degraded performance, hidden SPOFs, etc., and therefore
will not be supported by HP.
What’s Defined in a Cluster
Cluster
SPUs
Local and Shared Storage
Intra-cluster and Client LANs
Shared Storage Cabling
Cluster
Type of SPUs
HP NetServer LPr.
Each node must be the same model SPU, but may have different clocks
speeds, main memory sizes, cache sizes, and number of CPUs (2, 3, or 4).
Number of nodes
2
Shared Storage
XP256 with FC or SCSI connections. See
Shared Storage
below.
LANs:
Client LAN
Any NIC that is HP and Microsoft approved. See
Client LAN
below.
Intra-cluster
(Heartbeat) LAN
HP D5013A with crossover cable. See
Intra-cluster LAN
below.
Power source
Direct from power mains, power conditioner or uninterruptible power
supply (UPS) using any power conditioner or UPS.
System software:
Navigator version
L.16.05 or later
Operating System
Microsoft Windows NT Server 4.0, Enterprise Edition or later
Service pack
SP5 or later
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 SPU Model HP NetServer LPr. Clock speed 400, 450, 500, or 550 MHz No. of CPUs 2 – 4 BIOS version 4.06.14PR CPU cache Any size RAM 256 MB minimum. Must be HP. No. of power supplies 3 Local storage See Local Storage below. I/O slots: P1 – P4 Shared storage controller P2 – NetRAID-3Si local storage P...
3 XP256 Disk Array Microcode 43.12 (Direct Connect) 44.14 (All Configs) Open Volume Sizes (LDEVs) VOL TYPE SIZE MAX EXTENDED LUN SIZE Open 3*n 2.4G 2.4G x 36= 86.4G Open 8*n 7.2G 7.2G x 36= 259.2G (where “n”= 1-36) Open 9*n 7.3G 7.3G x 36= 262.8G Disk Capacities 15GB, 36GB, 47GB RAID levels 1 & ...
4 LANs Intra-cluster (Heartbeat) LAN Client LAN LAN connection HP D5954A crossover cable or equivalent Any LAN The intra-cluster LAN may only be used for cluster node communication via a crossover cable. It may not be used for client communication. NIC: Model HP D5013A (10/100TX PCI) Any that is on ...