HP XP256 - Manual

HP XP256

HP XP256 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
Page: / 5

Table of Contents:

  • Page 2 – SPU; Storage; Local; Fibre Channel HBA
  • Page 3 – VOL TYPE SIZE MAX EXTENDED LUN SIZE; Shared Storage Configurations
  • Page 4 – LANs; Client LAN
  • Page 5 – Shared Storage Cabling; LPr
Loading the manual

1

HP NetServer LPr

with

XP256 (Fibre Channel or SCSI)

Cluster Configuration Guide

08 February, 2000

Introduction

This document defines the supported HP NetServer LPr configurations with the XP256 and Microsoft
Cluster Server. These configurations minimize single points of failure (SPOF), provide maximum
availability, and have been certified by Hewlett-Packard or Microsoft. This guide is prescriptive; it
describes the configurations supported by HP. Any deviance to these configurations can result in an
inoperative cluster or an operating cluster with degraded performance, hidden SPOFs, etc., and therefore
will not be supported by HP.

What’s Defined in a Cluster

Cluster

SPUs

Local and Shared Storage

Intra-cluster and Client LANs

Shared Storage Cabling

Cluster

Type of SPUs

HP NetServer LPr.
Each node must be the same model SPU, but may have different clocks
speeds, main memory sizes, cache sizes, and number of CPUs (2, 3, or 4).

Number of nodes

2

Shared Storage

XP256 with FC or SCSI connections. See

Shared Storage

below.

LANs:

Client LAN

Any NIC that is HP and Microsoft approved. See

Client LAN

below.

Intra-cluster
(Heartbeat) LAN

HP D5013A with crossover cable. See

Intra-cluster LAN

below.

Power source

Direct from power mains, power conditioner or uninterruptible power
supply (UPS) using any power conditioner or UPS.

System software:

Navigator version

L.16.05 or later

Operating System

Microsoft Windows NT Server 4.0, Enterprise Edition or later

Service pack

SP5 or later

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SPU; Storage; Local; Fibre Channel HBA

2 SPU Model HP NetServer LPr. Clock speed 400, 450, 500, or 550 MHz No. of CPUs 2 – 4 BIOS version 4.06.14PR CPU cache Any size RAM 256 MB minimum. Must be HP. No. of power supplies 3 Local storage See Local Storage below. I/O slots: P1 – P4 Shared storage controller P2 – NetRAID-3Si local storage P...

Page 3 - VOL TYPE SIZE MAX EXTENDED LUN SIZE; Shared Storage Configurations

3 XP256 Disk Array Microcode 43.12 (Direct Connect) 44.14 (All Configs) Open Volume Sizes (LDEVs) VOL TYPE SIZE MAX EXTENDED LUN SIZE Open 3*n 2.4G 2.4G x 36= 86.4G Open 8*n 7.2G 7.2G x 36= 259.2G (where “n”= 1-36) Open 9*n 7.3G 7.3G x 36= 262.8G Disk Capacities 15GB, 36GB, 47GB RAID levels 1 & ...

Page 4 - LANs; Client LAN

4 LANs Intra-cluster (Heartbeat) LAN Client LAN LAN connection HP D5954A crossover cable or equivalent Any LAN The intra-cluster LAN may only be used for cluster node communication via a crossover cable. It may not be used for client communication. NIC: Model HP D5013A (10/100TX PCI) Any that is on ...

Other HP Models

All HP Other