Page 2 - Audience assumptions
© Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be constru...
Page 3 - Special Symbols; RISK OF ELECTRIC SHOCK; - Refer to your operator's manual for additional information,
Special Symbols The following are examples of symbols used on the UPS to alert you to important information: RISK OF ELECTRIC SHOCK - Observe the warning associated with the risk of electric shock symbol. CAUTION: REFER TO OPERATOR'S MANUAL - Refer to your operator's manual for additional informatio...
Page 4 - Regulatory compliance notices; Regulatory compliance identification numbers; Modifications; European Union regulatory notice
Regulatory compliance notices Regulatory compliance identification numbers For the purpose of regulatory compliance certifications and identification, this product has been assigned a unique regulatory model number.The regulatory model number can be found on the product nameplate label, along with a...
Page 5 - Japanese notice; Power cord statement for Japan; Electrostatic discharge; Preventing electrostatic discharge
This marking is valid for non-Telecom products and EU harmonized Telecom products (e.g. Bluetooth). This marking is valid for EU non-harmonized Telecom products. *Notified body number (used only if applicable—refer to the product label) Hewlett-Packard GmbH, HQ-TRE, Herrenberger Strasse 140, 71034 B...
Page 6 - Grounding methods to prevent electrostatic discharge
Grounding methods to prevent electrostatic discharge Several methods are used for grounding. Use one or more of the following methods when handling or installing electrostatic-sensitive parts: S Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis. Wrist straps ...
Page 7 - Table of Contents
HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 i Table of Contents 1 Introduction 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Safety Warnings 3 . . . . . . . . . . . ....
Page 8 - Figure 1 shows the HP T750 G2 UPS.; Figure 1
HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 1 Chapter 1 Introduction The HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, andHP T1500J Uninterruptible Power System (UPS) models protect your sensitive electronicequipment from b...
Page 9 - Backed by worldwide agency approvals.
INTRODUCTION HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 2 Providing outstanding performance and reliability, the UPS's unique benefits include: S Buck and Boost voltage regulation that ensures consistent voltage to your load bycorrecti...
Page 10 - IMPORTANT SAFETY INSTRUCTIONS; This UPS contains; LETHAL VOLTAGES; . All repairs and service should be performed by; AUTHORIZED SERVICE PERSONNEL ONLY
HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 3 Chapter 2 Safety Warnings IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions that you should follow during installation andmaintenance of the U...
Page 11 - Inspecting the Equipment; Figure 2
HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 4 Chapter 3 Installation This section explains: S Equipment inspection S UPS internal battery connection S UPS installation S UPS rear panels Inspecting the Equipment If any equipment has been...
Page 12 - battery cover to avoid damaging the battery disconnect blades.; Connect the red wire to the positive (; and does not damage the unit or present any safety concern.; Replace the metal battery cover.
INSTALLATION HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 5 3 Slide up and remove the metal battery cover (see Figure 3). Do not remove anyscrews. NOTE: For HP T750 G2, HP T750J, and HP T1000 G3 models, carefully remove the metal battery...
Page 13 - Installing the UPS; may occur to your equipment and void your warranty.; plug the detachable power cord into the input connector on; requirements of the heating elements.; Connect communication cable; Figure 6; Press and hold the
INSTALLATION HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 6 Installing the UPS NOTE: Do not make unauthorized changes to the UPS or accessories; otherwise, damage may occur to your equipment and void your warranty. To install the UPS: 1 ...
Page 14 - UPS Rear Panels; This section shows the UPS rear panels.; Figure 7
INSTALLATION HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 7 UPS Rear Panels This section shows the UPS rear panels. Four 5‐15 Receptacles 6-ft Power Cord with 5‐15 Plug Network TransientProtector Fan Serial Port DIP Switches Site Wiring ...
Page 15 - Figure 9
INSTALLATION HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 8 Six 5‐15 Receptacles 6-ft Power Cord with 5‐15 Plug Network TransientProtector Fan Serial Port DIP Switches Site Wiring Fault Indicator USB Port Input OvercurrentProtector Figur...
Page 16 - Fan
INSTALLATION HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 9 Six 10A, IEC-320Receptacles Fan 10A, IEC-320 Input Connector DIP Switches Network TransientProtector Serial Port USB Port Figure 12 HP T1500 G3, 230V Rear Panel
Page 17 - Turning the UPS On; default is the last frequency used by the UPS.
HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 10 Chapter 4 Operation This section describes: S Turning the UPS on and off S Starting the UPS on battery S Standby mode S The UPS front panel and indicators S Initiating the self‐test Turning...
Page 18 - Turning the UPS Off; Pressing the; Shut down the equipment connected to the UPS.; Standby Mode; Test/Alarm Reset Button; UPS Front Panel
OPERATION HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 11 Turning the UPS Off NOTE: Pressing the (On/Off) button while the UPS is in Battery mode causes the UPS to shut down immediately. To turn off the UPS: 1 Shut down the equipment con...
Page 19 - Initiating the Self‐Test; perform the self‐test.
OPERATION HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 12 Initiating the Self‐Test NOTE: The batteries must be fully charged and the UPS must not be in Battery mode to perform the self‐test. Press and hold the (Test/Alarm Reset) button f...
Page 20 - Voltage Configuration; To turn off the UPS, press and hold the; UPS Rear Panel; DIP Switches
HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 13 Chapter 5 Additional UPS Features This section describes: S Voltage configuration S USB port and serial port S Network transient protector S HP Power Manager software Voltage Configuration ...
Page 21 - Table 1; Communication Options; USB Port; To establish communication between the UPS and a computer:; The USB Port
ADDITIONAL UPS FEATURES HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 14 Table 1 DIP Switch Settings 100V Models Output Voltage Input Voltage Range DIP Switch 1 DIP Switch 2 100V 90–106V ON ON 120V Models Output Voltage Input Voltage Rang...
Page 22 - Serial Port; Signal Name
ADDITIONAL UPS FEATURES HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 15 Serial Port To establish communication between the UPS and a computer, connect your computerto the UPS serial port using the supplied communication cable. When the c...
Page 23 - Network Transient Protector; HP Power Manager Software; Prioritizes the timing of attached load device shutdowns.
ADDITIONAL UPS FEATURES HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 16 Network Transient Protector The network transient protector, shown in Figure 17, is located on the rear panel andhas jacks labeled IN and OUT. This feature accommoda...
Page 24 - UPS and Battery Care; Removing the UPS Front Bezel
HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 17 Chapter 6 UPS Maintenance This section explains how to: S Care for the UPS and batteries S Transport the UPS S Store the UPS and batteries S Order spare batteries S Replace the batteries S ...
Page 25 - Disconnect the red wire from the positive (; Disconnecting the Internal Battery Connector; Storing the UPS and Batteries
UPS MAINTENANCE HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 18 3 Slide up and remove the metal battery cover (see Figure 19). Do not remove anyscrews. NOTE: For HP T750 G2, HP T750J, and HP T1000 G3 models, carefully remove the metal ba...
Page 26 - UPS Battery Spares; Ordering Spares; Description
UPS MAINTENANCE HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 19 UPS Battery Spares Ordering Spares To order a spare, visit the HP website ( http://h61003.www6.hp.com ). To replace parts under warranty, contact an HP authorized service re...
Page 27 - Replacing Batteries; DO NOT DISCONNECT the batteries while the UPS is in Battery mode.; To replace the UPS internal battery:
UPS MAINTENANCE HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 20 Replacing Batteries NOTE: DO NOT DISCONNECT the batteries while the UPS is in Battery mode. With the hot‐swappable battery feature, batteries can be replaced easily without ...
Page 28 - Disconnect the red battery cable.
UPS MAINTENANCE HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 21 2 Slide up and remove the metal battery cover (see Figure 22). Do not remove anyscrews. NOTE: For HP T750 G2, HP T750J, and HP T1000 G3 models, carefully remove the metal ba...
Page 29 - Cable Retainer; Testing New Batteries; Allow batteries to charge for 6 to 24 hours before testing.
UPS MAINTENANCE HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 22 4 5 3 Cable Retainer Figure 24 Removing the Battery (HP T1000J, HP T1500J, HP T1500 G3 Models) 6 Replace the battery. See “Recycling the Used Battery or UPS” on page 23 forp...
Page 30 - Recycling the Used Battery or UPS
UPS MAINTENANCE HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 23 Recycling the Used Battery or UPS Contact your local recycling or hazardous waste center for information on properdisposal of the used battery or UPS. W A R N I N G S Do not...
Page 31 - Table 3; ±20% for nominal voltage at full load
HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 24 Chapter 7 Specifications This section provides the following specifications: S Model list S Dimensions and weights S Electrical input and output S Environmental and safety S Battery Table 3...
Page 32 - Table 6
SPECIFICATIONS HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 25 Table 6 Electrical Output 100V Models 120V Models 230V Models Power Levels (rated at nominalinputs) 100V: 750 VA, 500W 1000 VA, 680W1200 VA, 980W 110V and 120V: 750 VA, 500W ...
Page 33 - Table 8; and no supplementary power supply load; Table 9
SPECIFICATIONS HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 26 Table 8 Battery UPS Configuration HP T750 G2: (2) 12V, 7 or 7.2 Ah internal batteries HP T750J and HP T1000 G3: (2) 12V, 9 Ah internal batteries HP T1000J, HP T1500 G3, and H...
Page 34 - This section explains:; Audible Alarms and UPS Conditions; Indicator Legend; Silencing an Audible Alarm; To silence the alarm for an existing fault, press the; Site Wiring Fault (100–120V Models Only)
HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 27 Chapter 8 Troubleshooting This section explains: S UPS alarms and conditions S How to silence an alarm S Site wiring fault (100–120V models only) S Service and support Audible Alarms and UP...
Page 35 - Troubleshooting Guide; Alarm or Condition
TROUBLESHOOTING HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 28 Table 10 Troubleshooting Guide Alarm or Condition Possible Cause Action The indicator is not on; the UPSdoes not start. The power cord is notconnected correctly. Check the p...
Page 36 - Action; Technical Support; Before You Contact HP
TROUBLESHOOTING HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 29 Table 10 Troubleshooting Guide (continued) Action Possible Cause Alarm or Condition Continuous beep. UPS internal temperature is toohigh. Shutdown is imminent. Save your wor...
Page 37 - HP Contact Information; For the name of the nearest HP authorized reseller:
TROUBLESHOOTING HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 30 HP Contact Information For the name of the nearest HP authorized reseller: S In the United States, see the HP US service locator webpage( http://www.hp.com/service_locator )...
Page 38 - Limited Warranty; United States and Canada.; The $250,000 Computer Load Protection Guarantee only applies if:; Pre-Failure Battery Warranty; An LED showing the battery is low
HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 31 Chapter 9 Warranty Infromation Limited Warranty To back up the wide range of features offered with the UPS, a 3-year limited warranty isprovided. $250,000 Computer Load Protection Guarantee...