Page 5 - Contents; Switch Overview
Contents iii 1 Switch Overview Switch Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Switch Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 2 I...
Page 6 - Hardware Diagnostic Tests; A Specifications; Safety Information; C Recycle Statements
iv Hardware Diagnostic Tests . . . . . . . . . . . . . . . . . . . . . . . . . 4-5 Testing the Switch by Resetting It . . . . . . . . . . . . . . . . . . 4-5 HP Customer Support Services . . . . . . . . . . . . . . . . . . . . . 4-5 Before Calling Support . . . . . . . . . . . . . . . . . . . . . . ...
Page 7 - Switch Hardware Features; Switch Ports
1-1 1 Switch Overview Switch Hardware Features The ProCurve Switch 1800-8G (J9029A) is a multiport switch that can be used to build high-performance switched workgroup networks. This switch is a store-and-forward device that offers low latency for high-speed networking. Switch Ports The switch has 8...
Page 8 - LEDs
1-2 Switch Overview Switch Hardware Features LEDs The front panel of the switch provides status LEDs for system monitoring. The following table details the functions of the various indicators. System LED State Meaning Power(green) On The switch is receiving power. Off The switch is NOT receiving pow...
Page 9 - Switch Features
1-3 Switch Overview Switch Hardware Features Switch Features The features of the ProCurve Switch 1800-8G include: ■ 8 auto-sensing 10/100/1000Base-T RJ-45 ports. ■ plug-and-play networking—all ports are enabled—just connect the network cables to active network devices and your switched network is op...
Page 11 - Installing the Switch; Included Parts
2-1 2 Installing the Switch The ProCurve Switch 1800-8G is easy to install. It comes with rubber feet that can be attached so the switch can be securely located on a horizontal surface. This chapter shows how to install the switch. Included Parts The following components ship with a ProCurve Switch ...
Page 13 - Installation Procedures; Summary; Prepare the installation site.; Verify the switch passes self test.; Connect power to the switch.
2-3 Installing the Switch Installation Procedures Installation Procedures Summary Follow these easy steps to install your switch. The rest of this chapter provides details on these steps. 1. Prepare the installation site. Make sure of the following: • the network cabling is the correct type and leng...
Page 14 - Installation Precautions:; Ca u t i on s
2-4 Installing the Switch Installation Procedures Installation Precautions: Follow these precautions when installing your switch. Ca u t i on s ■ Make sure you use the power adapter supplied with the switch to connect it to an AC power source. ■ When installing the switch, since the unit does not ha...
Page 15 - Prepare the Installation Site; Cabling Infrastructure; Installation Location
2-5 Installing the Switch Installation Procedures 1. Prepare the Installation Site ■ Cabling Infrastructure - To ensure proper operation when installing the switch into a network, make sure that the current cables are suitable for 10Base-T, 100Base-TX, or 1000Base-T operation. Be sure to follow the ...
Page 16 - Verify the Switch Passes Self Test; No t e
2-6 Installing the Switch Installation Procedures 2. Verify the Switch Passes Self Test Before mounting the switch in its network location, you should first check that it is working properly by plugging it into a power source and verifying that it passes its self test. 1. Connect the adapter’s power...
Page 17 - Self Test LED Behavior:; During the self test:; Fault; FDx; Spd
2-7 Installing the Switch Installation Procedures 2. Check the LEDs on the switch. The LED behavior is described below. When the switch is powered on, it performs its diagnostic self test. The self test takes approximately 8 seconds to complete. Self Test LED Behavior: During the self test: • The LE...
Page 18 - Horizontal Surface Mounting; Connect the Switch to a Power Source
2-8 Installing the Switch Installation Procedures 3. Mount the Switch After you have verified that the switch passes its self test, you are ready to mount the switch in a stable location. The switch can be mounted on a horizontal surface. Horizontal Surface Mounting Place the switch on a table or ot...
Page 19 - Connect the Network Cables
2-9 Installing the Switch Installation Procedures 5. Connect the Network Cables Using the RJ-45 Connectors (10/100/1000Base-T ports) To connect: Push the RJ-45 plug into the RJ-45 jack until the tab on the plug clicks into place. When power is on for the switch and for the connected device, the Link...
Page 21 - Configuring the Switch; Initial Configuration
3-1 3 Configuring the Switch Initial Configuration The ProCurve Switch 1800-8G can be managed through a Web-browser interface that you can access from any PC or workstation in the connected network. For initial configuration, you may want to assign an IP address to the switch that is compatible with...
Page 22 - Changing PC’s IP Address
3-2 Configuring the Switch Changing PC’s IP Address address to 192.168.2.x (where "x" can be any number from 1 to 255, except 10). If you are unfamiliar with this process, see “Changing PC’s IP Address” on page 3-2. 4. Open your Web browser and enter the address http://192.168.2.10. If your ...
Page 23 - Where to Go From Here
3-3 Configuring the Switch Where to Go From Here 3. In General tab, under Components checked are used by this connection , click to select Internet Protocol (TCP/IP) , and then click Properties to open Internet Protocol (TCP/IP) Properties dialog box. 4. In Internet Protocol (TCP/IP) Properties dial...
Page 25 - Troubleshooting; Basic Troubleshooting Tips
4-1 4 Troubleshooting This section describes how to troubleshoot the switch. For more information, see the chapter “Troubleshooting” in the ProCurve Series 1800 Switch Management and Configuration Guide , which is available on the ProCurve Networking Web site, http://www.procurve.com . This chapter ...
Page 26 - Diagnosing With the LEDs
4-2 Troubleshooting Diagnosing With the LEDs Diagnosing With the LEDs LED patterns on the switch may indicate a problem condition. 1. Check in the table for the LED pattern that you see on your switch. 2. Refer to the corresponding diagnostic tip on the next few pages. Problem Resolution Switch fail...
Page 29 - Testing the Switch by Resetting It; HP Customer Support Services
4-5 Troubleshooting Hardware Diagnostic Tests Hardware Diagnostic Tests Testing the Switch by Resetting It If you believe that the switch is not operating correctly, you can reset the switch to test its circuitry. To reset the switch, unplug and plug in the power adapter (power cycling). Power cycli...
Page 30 - Before Calling Support
4-6 Troubleshooting HP Customer Support Services Before Calling Support Before calling your networking dealer or HP Support, to make the support process most efficient, you first should have retrieved the following information: Information Item Information Location • product identification the front...
Page 31 - Specifications; Physical
A-1 A Specifications Physical Electrical Environmental Width: 19.6 cm (7.7 in) Depth: 11.6 cm (4.5 in) Height: 4.4 cm (1.73 in) Weight : 0.54 kg (1.19 lbs) DC voltage: 12-13 volts Maximum current: 1.0-0.8 A Operating Non-Operating Temperature: 0 ° C to 40 ° C (32 ° F to 104 ° F) -40 ° C to 70 ° C (-...
Page 32 - Connectors
A-2 Specifications Connectors ■ The 10/100/1000 Mbps RJ-45 twisted-pair ports are compatible with the following standards: • IEEE 802.3ab 1000Base-T • IEEE 802.3u 100Base-TX • IEEE 802.3 10Base-T Safety The switch complies with these safety standards: ■ EN60950-1 / IEC 60950-1 ■ CSA 22.2 No. 60950-1...
Page 33 - Grounding
B-1 B Safety and EMC Regulatory Statements Safety Information Grounding These are safety class I products and have protective earthing terminals. There must be an uninterruptible safety earth ground from the main power source to the product’s input wiring terminals, power cord, or supplied power cor...
Page 34 - Servicing
B-2 Safety and EMC Regulatory Statements Safety Information For LAN cable grounding: ■ If your LAN covers an area served by more than one power distribution system, be sure their safety grounds are securely interconnected. ■ LAN cables may occasionally be subject to hazardous tran-sient voltages (su...
Page 35 - Informations concernant la sécurité
B-3 Safety and EMC Regulatory Statements Safety Information Informations concernant la sécurité Cet appareil est un produit de classe I et possède une borne de mise à la terre. La source d'alimentation principale doit être munie d'une prise de terre de sécurité installée aux bornes du câblage d'entr...
Page 37 - Hinweise zur Sicherheit
B-5 Safety and EMC Regulatory Statements Safety Information Hinweise zur Sicherheit Dies ist ein Gerät der Sicherheitsklasse I und verfügt über einen schützenden Erdungsterminal. Der Betrieb des Geräts erfordert eine ununterbrochene Sicherheitserdung von der Hauptstromquelle zu den Geräteingabetermi...
Page 39 - Considerazioni sulla sicurezza
B-7 Safety and EMC Regulatory Statements Safety Information Considerazioni sulla sicurezza Questo prodotto è omologato nella classe di sicurezza I ed ha un terminale protettivo di collegamento a terra. Dev'essere installato un collegamento a terra di sicurezza, non interrompibile che vada dalla font...
Page 41 - Consideraciones sobre seguridad
B-9 Safety and EMC Regulatory Statements Safety Information Consideraciones sobre seguridad Este aparato se enmarca dentro de la clase I de seguridad y se encuentra protegido por una borna de puesta a tierra. Es preciso que exista una puesta a tierra continua desde la toma de alimentación eléctrica ...
Page 45 - EMC Regulatory Statements; Canada; Australia/New Zealand
B-13 Safety and EMC Regulatory Statements EMC Regulatory Statements EMC Regulatory Statements U.S.A. FCC Class A This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable prot...
Page 46 - Japan; Korea
B-14 Safety and EMC Regulatory Statements EMC Regulatory Statements Japan VCCI Class A Korea Taiwan
Page 47 - European Community
B-15 Safety and EMC Regulatory Statements EMC Regulatory Statements European Community DECLARATION OF CONFORMITY according to ISO/IEC Guide 22 and EN45014 Manufacturer's Name: Hewlett-Packard Company Manufacturer's Address: 8000 Foothills Blvd Roseville, CA 95747-5502 U.S.A. declares that the produc...
Page 49 - Recycle Statements
C-1 C Recycle Statements Waste Electrical and Electronic Equipment (WEEE) Statements Disposal of Waste Equipment by Users in Private Household in the European Union This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Ins...
Page 59 - Index
Index – 1 B basic troubleshooting tips … 3-3, 4-1 C cables connecting cables to switch ports … 2-9 connecting the switch to a power source … 2-8 connector specifications … A-2 D description LEDs … 1-2 diagnostic tests … 4-5 testing the switch only … 4-5 – 4-6 E electrical specifications, switch … A-...