  • Page 2 – INSTALLATION; When Installing this Product...; Converting Between Natural and LP Gas; WARNING; Install Adapters to Gas Control
  • Page 3 – Choose Gas Control Location; Install Piping to Gas Control
  • Page 4 – Install Gas Control; Connect Pilot Gas Tubing
  • Page 5 – Connect Thermocouple; Wiring; CAUTION; Install Thermocouple
  • Page 6 – START-UP AND CHECKOUT; Gas Control Knob Settings; Perform Gas Leak Test; Gas Leak Test
  • Page 7 – Light Pilot Burner Flame; Check and Adjust Gas Input to Main Burner
  • Page 8 – Check Safety Shutdown Performance; MAINTENANCE
  • Page 9 – SERVICE; If Pilot Burner Flame does not Light:
  • Page 10 – Lighting the Pilot Burner Flame; Turning Off Appliance
Loading the manual

X-XX UL

INSTALLATION INSTRUCTIONS

®U.S. Registered Trademark
Copyright © 1998 Honeywell Inc. • All Rights Reserved

69-0668-1

VR8300A Continuous Pilot Combination

Gas Control

APPLICATION

These continuous pilot gas controls are used in gas-fired
appliances with capacities up to 200 cfh at 1 in. wc
pressure drop (5.7 cmh at 0.25 kPa) on natural gas.
Included are a manual valve, safety shutoff, two automatic
operators, and a pressure regulator. See Table 2 for
temperature range and regulator type.

The VR8300 setup for natural gas includes a 39369 LP
Conversion Kit. The kit contains a new cap screw, a
pressure regulator adjustment screw, a tapered spring and
a conversion label. The control must be equipped with a
standard servo pressure regulator. Step-opening gas
controls cannot be converted.

Body Pattern:
Straight-through body pattern.

Inlet x Outlet Sizes Available:
1/2 x 1/2 in., 1/2 x 3/4 in., and 3/4 x 3/4 in. (factory-installed
inlet flange).

Adapters:
Adapters available for 1/2 and 3/4 in. straight and angle
connections. Refer to Table 3.

Electrical Ratings:

Voltage and Frequency: 24 Vac, 50/60 Hz.
Current Draw: 0.70A.

Capacity:

a

Capacity based on 1000 Btu/cu ft, 0.64 specific gravity natural gas at 1 in. wc pressure drop (37.3 MJ/cu m, 0.64 specific

gravity natural gas at 0.25 kPa pressure drop).

Use conversion factors in Table 1 to convert capacities for
other gases.

Table 1. Gas Capacity Conversion Factors.

Gas

Specific

Gravity

Multiply Listed

Capacity By

Manufactured

0.60

0.516

Mixed

0.70

0.765

Propane

1.53

1.62

Table 2. Temperature Range and Regulator Type.

Table 3. Flange Part Numbers.

Part Number

Inlet/Outlet

Pipe Size

Flange

Type

Without Hex

Wrench

With Hex

Wrench

1/2 in. NPT

Straight

393690-6

393690-16

Elbow

393690-3

393690-13

3/4 in. NPT

Straight

393690-4

393690-14

Elbow

393690-5

393690-15

NOTE:

Flange kits include one flange with attached
O-ring and fan mounting screw.

Approvals:

International Approval Services Listed: L2025007.
Australian Gas Association Certificate: Applied for.
Delta C: Pending approval.

Size (Inlet x Outlet)

Capacity at 1 in. wc

Pressure Drop

a

Minimum Regulated

Capacity

Maximum Regulated

Capacity

1/2 in. x 1/2 in.

180 cfh (5.1 cmh)

30 cfh (0.8 cmh)

225 cfh (6.4 cmh)

1/2 in. x 3/4 in.

190 cfh (5.4 cmh)

30 cfh 0.8 cmh)

290 cfh (8.2 cmh)

3/4 in. x 3/4 in.

200 cfh (5.7 cmh)

30 cfh (0.8 cmh)

300 cfh (8.5 cmh)

Model

Ambient

Temperature Range

Regulator

Number

°

F

°

C

Type

VR8300A

0

°

to 175

°

18

°

to 79

°

Standard-opening

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Honeywell VR8300A

Summary

Page 2 - INSTALLATION; When Installing this Product...; Converting Between Natural and LP Gas; WARNING; Install Adapters to Gas Control

69-0668—1 2 VR8300A CONTINUOUS PILOT COMBINATION GAS CONTROL INSTALLATION When Installing this Product… 1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazard-ous condition. 2. Check the ratings given in the instructions and on the product to make sur...

Page 3 - Choose Gas Control Location; Install Piping to Gas Control

69-0668—1 3 VR8300A CONTINUOUS PILOT COMBINATION GAS CONTROL COLOR CODE FOR LPGAS NATRUALGAS CAP SCREW BLACK SILVER PRESSUREREGULATORADJUSTINGSCREW WHITE WHITE TAPEREDSPRING RED STAINLESSSTEEL PRESSUREREGULATORHOUSING M16015 Fig. 1. Install conversion kit in regulated gas control. Bushings: 1. Remov...

Page 4 - Install Gas Control; Connect Pilot Gas Tubing

69-0668—1 4 VR8300A CONTINUOUS PILOT COMBINATION GAS CONTROL Install Gas Control To install: 1. Mount the gas control 0 to 90 degrees, in any direction, from the upright position of the gas controlknob, including vertically. 2. Mount the gas control so the gas flow is in the direction of the arrow o...