Honeywell Thermostat T8411R- User Manual

Honeywell Thermostat T8411R

Honeywell Thermostat T8411R– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
Page: / 6

Table of Contents:

  • Page 2 – T8411R ELECTRONIC HEAT PUMP THERMOSTAT; Wiring; IMPORTANT; CAUTION; Electrical Shock or Equipment Damage; Disconnect power supply before installation.
  • Page 3 – Mounting Thermostat to Wallplate; Engage the tabs at the top of the thermostat and
  • Page 4 – OPERATION; Setting FAN and SYSTEM Switches; FAN Switch
  • Page 5 – Set Temperature Setpoint; Setting °F/°C Indication and Heat Cycle Rate; OPTIONAL SYSTEM CHECKOUT
  • Page 6 – Printed in Mexico; CHECKOUT; Heating; Equipment Damage Hazard.; Fan; System; or
Loading the manual

® U.S. Registered Trademark
Copyright © 2002 Honeywell • •All Rights Reserved

INSTALLATION INSTRUCTIONS

69- 1486- 1

T8411R Electronic

Heat Pump Thermostat

The T8411R Heat Pump Thermostat provides 24V

control of two-stage heating and one-stage cooling heat
pump system with manual changeover from heat to cool.

First stage heating and cooling cycle rates are fixed at
3 cph. Second stage heating cycle rate is selectable at

3, 4, 5, 6, 9 or 12 cph. Temperature indication can be set
for °F or °C.

The T8411R Heat Pump Thermostat is powered directly

from the system transformer. Batteries are not required
because setpoints are held permanently by non-volatile

memory.

The T8411R includes a thermostat, wallplate (for wiring
and mounting thermostat), and owner’s guide. A 7 3/8 in.

x 5 3/4 in. (188mm x146 mm) decorator cover plate (for
covering wall marks) is available separately. Order

Honeywell part no. 209649A (taupe color).

MERCURY NOTICE

If this control is replacing a control that contains

mercury in a sealed tube, do not place your old
control in the trash.

Contact your local waste management authority

for instructions regarding recycling and the
proper disposal of an old control containing

mercury in a sealed tube.

INSTALLATION

When Installing this Product…

1.

Read these instructions carefully. Failure to follow

them could damage the product or cause a hazard-
ous condition.

2.

Check the ratings given in the instructions and on
the product to make sure the product is suitable for

your application.

3.

Installer must be a trained, experienced service

technician.

4.

After installation is complete, check out product

operation as provided in these instructions.

CAUTION

Electrical Shock or Equipment Damage
Hazard.

Can shock individuals or short equipment
circuitry.

Disconnect power supply before installation.

Location

Install the thermostat about 5 ft (1.5m) above the floor in
an area with good air circulation at average temperature.

See Fig. 1. Do not install the thermostat where it can be
affected by:

— drafts or dead spots behind doors and in corners.
— hot or cold air from ducts.

— radiant heat from the sun or appliances.
— concealed pipes and chimneys.

— unheated (uncooled) areas such as an outside wall

behind the thermostat.

This thermostat is a precision instrument and was

carefully adjusted at the factory. Handle it carefully.

Mounting Wallplate to Wall

IMPORTANT

Level only for appearance. The thermostat func-
tions normally even when not level.

Mount wallplate, T8411R and the screws provided (see

Fig. 2) as follows:

1.

Place the wallplate at the desired location on the

wall.

2.

Use a pencil to mark the mounting holes.

3.

Remove the wallplate from the wall and drill two
3/16 in. holes in the wall (if drywall) or two 7/32 in.

holes for firmer material such as plaster or wood.

4.

Gently tap the anchors (provided) into the holes

until flush with the wall.

5.

Position the wallplate over the holes.

6.

Pull the thermostat wire through the wallplate
entrance hole.

7.

Fasten the wallplate to the wall using the anchors
and screws provided.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - T8411R ELECTRONIC HEAT PUMP THERMOSTAT; Wiring; IMPORTANT; CAUTION; Electrical Shock or Equipment Damage; Disconnect power supply before installation.

T8411R ELECTRONIC HEAT PUMP THERMOSTAT 69-1486-1 2 Fig. 1. Typical location of thermostat. Fig. 2. Mounting wallplate to wall. Wiring IMPORTANT Use an 18-gauge maximum wire for wiring the T8411R Thermostat. All wiring must comply with local electrical codes and ordinances. CAUTION Electrical Shock o...

Page 3 - Mounting Thermostat to Wallplate; Engage the tabs at the top of the thermostat and

T8411R ELECTRONIC HEAT PUMP THERMOSTAT 3 69-1486-1 Fig. 4. Restrict wiring to shaded area. Refer to Fig. 5 for typical wiring hookups. A letter code is located near each terminal for identification. 1. Loosen the terminal screws on the wallplate and connect the system wires. See Fig. 5. 2. Securely ...

Page 4 - OPERATION; Setting FAN and SYSTEM Switches; FAN Switch

T8411R ELECTRONIC HEAT PUMP THERMOSTAT 69-1486-1 4 Fig. 6. Mounting thermostat wallplate. OPERATION Setting FAN and SYSTEM Switches Fan and system settings are controlled manually by using the switches located at the bottom of the thermostat case. See Fig. 7. FAN Switch Fan switch settings are: On: ...