Table of Contents:

  • Page 2 – Configuration Menu; Program Menu; Be careful about overlapping!
  • Page 3 – Menu Mode; Menu Heure; Time; Applications; Guide de l’utilisateur; Interrupteur mural programmable — solaire et 7 jours
  • Page 4 – Menu Configuration; Menu Programme; Sélectionner un numéro de programme; Attention au chevauchement!
  • Page 5 – Menú Modo; Mode; Menú Hora; Aplicaciones; Guía del usuario; Interruptor mural programable solar de 7 días
  • Page 6 – Menú Configuración; Menú Programa; Ajuste de la hora de inicio del programa; ¡Cuidado con la superposición!; Bloqueo de los ajustes
  • Page 7 – Legend; Legende; Menu flowchart; Organigramme des menus
Loading the manual

PLS750C/PLS751C

1/8

PLS750C/PLS751C

User guide

7-day Solar Programmable Wall Switch

The PLS750C/PLS751C programmable wall switch has been designed to control lights and motors:

Cut power at the circuit breaker to avoid electric shock.

Remove the existing switch. (For a 3-way installation, identify and label the wire that is connected to
the “common” screw.)

Install the new switch (see the appropriate section below).

Apply power at the circuit breaker.

SINGLE-SWITCH INSTALLATION

EXISTING 3-WAY INSTALLATION

Connect the LOAD wire on the PLS750C/PLS751C to the “common” wire, which you identified when
removing the old switch. Connect the NEUTRAL wire to the neutral (white) wires. Connect the LINE and 3-
WAY wires to the two remaining wires. At the other 3-way switch, connect the jumper wire between the
“common” screw and the screw where the LINE wire of the PLS750C/PLS751C is connected.

NOTE

: If the timer screen does not turn on when you apply power at the circuit break (step 4), cut the power

at the circuit breaker again, switch the blue (LOAD) and the black (LINE) wires and reapply power.

NEW 3-WAY INSTALLATION

The switch will turn the lights on at sunset and turn them off at 11:00 pm by default. If these settings are
appropriate for you, you only need to set the time and date (see shaded zone in the menu flowchart sheet).
If the switch’s sunset time does not correspond to the actual sunset time, see sections 5.3.3 and 5.3.4.

5.1

Mode Menu

You can use the Mode menu to select one of the three modes of operation (see sections 5.1.1 to 5.1.3).

5.1.1 Manual Mode

In Manual mode, the switch operates like a regular switch. To turn the lights on or off,
briefly press the main button. The icon appears when the switch is in Manual mode.

5.1.2 Automatic Mode

In Automatic mode, the switch turns the lights on or off according to the set programs (see
Section 5.4). The

icon as well as the current program number are displayed.

5.1.3 Random Mode

In Random mode, the switch has no specific times to turn the lights on or off. This mode is
designed to give the impression the house is occupied during your absence. It is similar to the
Automatic mode except there is no fixed program. The programs are automatically set to different
times by the switch every day. The

icon appears when the switch is in Random mode.

The first “On” program occurs at sunset. Each “On” program lasts between 1 hour and 1
hour and 30 minutes; each “Off” program lasts between 15 and 30 minutes. The last “Off”
program occurs between 10:30 pm and midnight.

5.1.4 Temporary Override

When the switch is in Automatic or Random mode, you can press the main button at any time to override the
default state for the current program. The lights will turn off if they are on and vice versa. The icon (On or Off)
of the new state flashes to indicate that the state is temporary. The new state is maintained until you press
the main button again or till the next “On” or “Off” program.

5.2

Time Menu

The time display flashes on the screen when the time has not yet been set or after a 4-hour power outage.
Use the Time menu to select the time format (12-hour or 24-hour) and to set the clock and date.

NOTE

: The date is used to determine the sunset and sunrise times.

Applications

1.

Load types

Maximum load

Examples

Lights and resistive loads
(except tungsten)

1800 W (15 A @ 120 V)

fluorescent lights

compact fluorescent lights (CFL)

electronic ballasts

sodium lamps

block heaters

Tungsten lights

1440 W (12 A @ 120 V)

incandescent lights

halogen lights

Motors

1 hp

pool filter pumps

fans

Installation

2.

black (LINE)

yellow (3-WAY)

120
VAC

blue (LOAD)

white (NEUTRAL)

black

white

black

white

120 VAC

red

jumper

black

white

black (LINE)

yellow (3-WAY)

blue (LOAD)

white (NEUTRAL)

black

white

black

white

three-way
switch

120
VAC

black

white

black

white

black

white

black (LINE)

yellow (3 WAY)

blue (LOAD)

white (NEUTRAL)

single-pole
switch

Quick Start-up

3.

Set the time and date before using the timer for the first time.

Operation

4.

Setup Menus

5.

Press the main button for 3 seconds to enter the setup menus. Refer to
the menu flowchart sheet on how to navigate the menus.

The icon indicates the current
program has been activated at sunset.
The

icon indicates the current

program has been activated at sunrise.

The LED illuminates when the load
state is on.

Briefly press this button to turn the
lights on or off. See “Temporary
Override” in Section 5.1.4.

Press for 3 seconds to enter the
setup menus.

Indicates the mode of operation
(see Section 5.1)

Indicates the current program

Indicates the load on/off state

Indicates the time and day

Indicates the keypad is locked
(see Section 6)

Press this button to display today’s sunrise time.
Press this button to display today’s sunset time.

(3 sec.)

NOTE:

This switch cannot be used if there is no neutral wire
(white wires joint together) inside the electrical box.

69-2504EFS-03 (TI072-3W Honeywell PLS750C_PLS751C).book Page 1 Thursday, September 15, 2011 3:49 PM

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Configuration Menu; Program Menu; Be careful about overlapping!

PLS750C/PLS751C 2/8 5.3 Configuration Menu ( Conf ) Use the Configuration menu to set the following parameters (seesections 5.3.1 to 5.3.4). 5.3.1 Backlight mode ( SCRN ) The screen is lit at high intensity for 8 seconds when you press anybutton. The rest of the time, depending on the backlight mode...

Page 3 - Menu Mode; Menu Heure; Time; Applications; Guide de l’utilisateur; Interrupteur mural programmable — solaire et 7 jours

PLS750C/PLS751C 3/8 L’interrupteur mural programmable PLS750C/PLS751C a été conçu pour commander des appareilsd’éclairage et des moteurs.  Mettre le circuit hors tension à partir du disjoncteur afin d'éviter tout risque de choc électrique.  Enlever l’interrupteur existant (pour une installation à ...

Page 4 - Menu Configuration; Menu Programme; Sélectionner un numéro de programme; Attention au chevauchement!

PLS750C/PLS751C 4/8 NOTA : La date sert à déterminer l’heure du coucher du soleil et celle du lever du soleil. 5.3 Menu Configuration ( Conf ) Utiliser le menu Configuration pour régler les paramètres suivants(voir les sections 5.3.1 à 5.3.4). 5.3.1 Mode de rétroéclairage ( SCRN ) L'écran est allumé...

Other Honeywell Models