6

7

8

9

VisionPRO

®

8000

Thermostats

InsTalleR seTuP and

sysTem TesT POckeT GuIde

InsTalleR sysTem TesT

The Installer Test is part of the Installer Setup Menu.

Enter the Installer System Test by entering the Installer

Setup and pressing

t

repeatedly until “Test” appears.

DONE

M24083

Use arrow to change test and system status as

required.

DONE

M24085

TEST NUMBER

SYSTEM STATUS

Press

DONE

to exit.

1.

2.

3.

sysTem TesTs

Test the system’s heating, cooling, fan and emergency heat.

Available tests vary by thermostat and system type.

Table 2. Installer System Test

System Test

Number

Test Type

System Status Number

and Description

Test 1

Cooling System

Test

0

Off

1

Compressor and

fan on

2

Second stage

compressor on

Test 2

Fan System

Test

0

Off

1

Fan on

Test 3

Heating System

Test

0

Off

1

Heat on

2

Second stage heat

(Aux. heat) on

3

Third stage heat

(Auxiliary heat) on

Test 4

Emergency

Heat Test

0

Off

1

Em. Heat and fan on

2

Auxiliary heat on

Press the

DONE

button to exit the Installer System Test.

caution

EQUIPMENT DAMAGE HAZARD.

Compressor protection is bypassed during testing. To

prevent equipment damage, avoid cycling the compres-

sor quickly.

Table 1. Installer Setup

Setup functions

Setting & Options (factory

default in bold)

0520

U/V lamp change

reminder

0

Off

1

365 calendar days

0530

Adaptive Intel-

ligent Recovery

TM

1

On

0

Off

0540

Program periods

4

4 periods (Wake,

Leave, Return, Sleep)

2

2 periods (Wake, Sleep)

0580

Compressor

protection

5

5-minute compressor

off time

[Other options: 0–4

minutes]

0600

Heat temperature

range stop

90

Max. heat temperature

setting is 90°F (32°C)

[Other options: 40-89°F

(4°C to 32°C)]

0610

Cool temperature

range stop

50

Min. cool temperature

setting is 50°F (10°C)

[Other options: 51-99°F

(11°C to 37°C)]

0640

Clock format

12

12-hour time

24

24-hour time

0650

Extended fan

timer (heat)

0

Off

90

Fan runs for 90 seconds

after call for heat ends

0660

Extended fan

timer (cool)

0

Off

90

Fan runs for 90 seconds

after call for cooling ends

0670

Keypad Lockout

0

Unlocked

1

Partially locked

2

Fully locked

Table 1. Installer Setup

Setup functions

Setting & Options (factory

default in bold)

0680

Heat temperature

control

2

Standard temperature

control (recommended)

1

Select if inside tempera-

ture is consistently over

setting

3

Select if inside tempera-

ture is consistently under

setting

0690

Cool temperature

control

2

Standard temperature

control (recommended)

1

Select if inside tempera-

ture is consistently over

setting

3

Select if inside tempera-

ture is consistently under

setting

0700

Temperature

display offset

0

No offset

[Other options: -3, -2,

-1, 1, 2, 3°F (-1.5°C to

1.5°C)]

0710

RESET

0

No reset

1

Reset installer options

& program schedule to

factory default

69-1871-1

InsTalleR seTuP

Press

SYSTEM

.

SCHED HOLD

FAN

ON

AUTO

AM

SYSTEM

HEAT

Inside

M24079

1.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.