Honeywell 1114 - Manual
Honeywell 1114 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 3 – GENERAL; Trademark Information
- Page 4 – Dimensions; Fig. 2 Spyder Model 7 VAV Dimensions; NETWORK SECURITY; WARNING; GENERAL SAFETY; CAUTION
- Page 5 – SPECIFICATIONS; Electrical
- Page 6 – Communications; Range
- Page 7 – Universal IO
- Page 8 – HARDWARE OVERVIEW; IP Model; Fig. 3 IP Model Hardware Overview; MSTP Model; Fig. 4 MSTP Model Hardware Overview
- Page 9 – Service Button; Fig. 5 Service Button Location; Pressing Service Button during normal operation; MOUNTING; Before Mounting Actuator; Fig. 6 Determining the Rotation Direction (CW or
- Page 10 – Mounting Actuator onto Damper
- Page 11 – and the angle of the damper open-to-closed is
- Page 12 – Airflow Sensor Connection; Fig. 11 Airflow Pickup Connections; Differential Pressure Installation
- Page 13 – Airflow Sensor Replacement; Fig. 12 Removing the Airflow Sensor Cover
- Page 14 – POWER SUPPLY; General Information
- Page 15 – Power Wiring Examples; Fig. 14 Power Wiring Examples
- Page 16 – INPUT / OUTPUT WIRING; Wiring Requirements; Single wire; Fig. 15 Attaching Two or More Wires at Terminal Block
- Page 17 – Internal Wiring Examples; IP Model Internal Wiring
- Page 18 – Terminal Connections
- Page 19 – UIO Wiring Examples; Fig. 18 Universal IO Wiring Examples
- Page 20 – 0 VDC Auxiliary Wiring Examples; Fig. 20 20 VDC Auxiliary Wiring
- Page 21 – NETWORK CONCEPTS; IP Network Topologies
- Page 22 – BACNET IP CONTROLLER; Enabled
- Page 23 – Remote Antenna Placement
- Page 24 – BACNET MSTP WIRING; Termination Resistors
- Page 25 – BACNET MSTP CONTROLLER; Automatic MAC Addressing
- Page 26 – Fig. 31 Calculating the MAC Address; Configure the Device Instance
- Page 27 – MODBUS RTU; Modbus Considerations; Cables and Shielding; X X
- Page 28 – SYLKTM BUS; Supported Sylk bus devices; Fig. 34 SylkTM Wiring Topologies
- Page 29 – BLUETOOTH BALANCING; Overview; Table 23 Mobile Application for Balancing
- Page 30 – TROUBLESHOOTING; BACnet and Modbus LED Status
- Page 31 – Bluetooth LED Status
- Page 32 – REGULATORY INFORMATION; FCC Regulation; Fig. 36 CE Statement; Professional Installation Warning
- Page 33 – Standards and Compliance; Article 33 Communication; Table 27 BLE Certification Numbers
- Page 34 – APPENDIX; Sensor Input Accuracy; Table 29 Sensor Accuracies
- Page 35 – Recognition of Sensor Failure of Sensor Inputs; Configuration
- Page 36 – Sensor Characteristics; 0 K NTC TYPE II Characteristics
- Page 38 – 0 K NTC TYPE III Characteristics; Table 32 10 K NTC TYPE III Characteristics
- Page 39 – Resistance
- Page 40 – Table 33 10 K3A1 Characteristics (Continued)
- Page 42 – 0 K NTC Characteristics; Table 34 20 K NTC Characteristics
- Page 43 – Table 34 20 K NTC Characteristics (Continued)
- Page 45 – Coefficients
- Page 46 – Sensor Type
- Page 47 – Characteristics
- Page 55 – ABBREVIATIONS
INSTALLATION INSTRUCTIONS
® U.S. Registered Trademark
Copyright © 2022 Honeywell Inc. • All Rights Reserved
31-00475-01
Spyder
TM
Model 7
VAV CONTROLLER
General ............................................................................... 3
Trademark Information .................................................... 3
Product Description........................................................... 3
Controller Part Numbers ................................................. 3
Dimensions ........................................................................... 4
Network Security ............................................................. 4
General Safety Instructions.......................................... 4
Specifications ................................................................... 5
Electrical ................................................................................ 5
Operational Environment................................................ 5
Hardware................................................................................ 5
Integrated Actuator..............................................................5
Communications ................................................................ 6
Modbus Client...................................................................... 6
Sylk™ Supported Devices................................................. 6
Differential Pressure Sensor .......................................... 6
Weight And Dimensions .................................................. 6
Universal IO........................................................................... 7
Solid State Relay (SSR) ..................................................... 7
Wireless Connectivity........................................................ 7
Hardware overview ......................................................... 8
IP Model ................................................................................. 8
MSTP Model ......................................................................... 8
Service Button...................................................................... 9
Mounting ........................................................................... 9
Before Mounting Actuator .............................................. 9
Mounting Actuator onto Damper Shaft................... 10
Airflow Sensor Connection ........................................... 12
Differential Pressure Installation
Recommendations ........................................................... 12
Airflow Sensor Replacement ........................................ 13
Power supply.................................................................. 14
General Information ........................................................ 14
Power Wiring....................................................................... 14
Power Wiring Examples.................................................. 15
Input / Output Wiring ................................................. 16
Wiring Requirements ...................................................... 16
Internal Wiring Examples .............................................. 17
Terminal Connections..................................................... 18
UIO Wiring Examples ...................................................... 19
SSR (DO) Wiring Examples ........................................... 20
20 VDC Auxiliary Wiring Examples ............................ 20
Network Concepts ........................................................ 21
The RS-485 Standard..................................................... 21
TIA/EIA 485 Cable Specifications .................................. 21
BACnet IP Controller ................................................... 22
WiFi (Future Release) .................................................. 22
Install the Local Antenna .............................................. 22
Install the Remote Antenna ......................................... 22
Remote Antenna Placement........................................ 23
BACnet MSTP Wiring ................................................... 24
BACnet MSTP Controller ............................................ 25
Automatic MAC Addressing ......................................... 25
Manual configuration of the MAC Address ........... 25
Configure the Device Instance Number.................. 26
Connect to the BACnet MSTP Network ................... 26
Modbus RTU................................................................... 27
Modbus Considerations ................................................ 27
................................................ 27
Sylk™ Bus ........................................................................ 28
Bluetooth Balancing .................................................... 29
Overview .............................................................................. 29
Troubleshooting............................................................ 30
BACnet and Modbus LED Status............................... 30
Bluetooth LED Status..................................................... 31
Controller LED Status .................................................... 31
Regulatory Information .............................................. 32
Professional Installation Warning.................................. 32
Detachable Antenna Warning (IC) ................................. 32
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Other Manuals for Honeywell 1114
Summary
SPYDER MODEL 7 VAV CONTROLLER INSTALLATION INSTRUCTIONS 3 31-00475-01 GENERAL Trademark Information • Spyder™ is a trademark of Honeywell International Inc. • BACnet® is a registered trademark of ASHRAE Inc. • Sylk™ is a trademark of Honeywell International Inc. Product Description Honeywell’s Spyde...
SPYDER MODEL 7 VAV CONTROLLER INSTALLATION INSTRUCTIONS 31-00475-01 4 Dimensions Fig. 2 Spyder Model 7 VAV Dimensions NETWORK SECURITY WARNING Honeywell hereby expressly states that the Spyder™ Model 7 VAV controllers are not inherently protected against all cyber security risks from the Internet an...
SPYDER MODEL 7 VAV CONTROLLER INSTALLATION INSTRUCTIONS 5 31-00475-01 SPECIFICATIONS Electrical Operational Environment Hardware Integrated Actuator Table 3 Electrical Specification Parameter Specification Rated input voltage 20 - 30 VAC; Class 2 transformer Nominal Power Consumption IP model: 8 VA;...