Hessaire MC37 - Quick Guide
Hessaire MC37 Evaporative Cooler – Quick Guide, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Inspection; are located in a compartment on the bottom side of the; Quick Start; Note: Media pads may have a slight odor upon initial start; Features; Control Panel For MC37A Model
- Page 3 – Maintenance; NEVER spray pads with water while cooler is in operation.; Removal Of Rigid Media:; Note: some pads may be held in place with pins (media; Removal Of Back Panel:; Visit Hessaire.com for additional maintenance tips and; Troubleshooting; Problem
- Page 4 – Parts; Cooler Parts; serial label number will be needed for all warranty claims.; What is not covered:; cooler repairs regardless if the product is under warranty or not.
- Page 5 – Enfriador evaporativo móvil; Guía de uso y cuidado; La unidad debe estar en posición; APAGADA; antes de; RETIRAR; los paneles de acceso.; Lea y siga todas las instrucciones, precauciones y ad-; Consejos de operación; Limpie las almohadillas de medios y el tanque con frecuencia.
- Page 6 – Inspección; Llena con agua; Inicio; Nota: las almohadillas de medios pueden tener un ligero ol-; Caracteristicas
- Page 7 – Mantenimiento; Eliminación de medios rígidos:; funcionar el ventilador sin bomba durante al menos 30 minutos.; Extracción del panel trasero:; Quite los dos tornillos Phillips de la; Soluciones; Problema; Fuga de agua
- Page 8 – Parte; Partes; Garantía Hessaire
Manual MC3761 Online ENG SPA 112721
INDEX
Safety Rules
……...
Quick Start
………..
Features
…………..
Maintenance
……...
Troubleshooting
….
Cooler Parts...
…....
Warranty
………..…
1
2
3
4
5
6
7
Mobile Evaporative Cooler
Use & Care Guide
MC37, MC61, M150, M250
M160, M260
3100, 5300 CFM
(color will vary by model)
General Safety Precautions
Unit must be in
OFF
position and
UNPLUGGED
from
power receptacle before performing any maintenance /
service or before
REMOVING
access panels.
Make sure the electrical power source conforms to the re-
quirement of the evaporative cooler as well as local codes.
To reduce risk of fire or electrical shock, do not expose
electrical connections to water.
Do not touch electrically live components.
Ensure all power cords do not touch sharp edges, hot sur-
faces or chemicals. Immediately replace damaged parts.
Never leave unit unattended.
Continuous fill not to be used indoors or unattended.
Read and follow all instructions, cautions
and warnings. Failure to do so could result
in personal injury, death or property damage.
Operation Tips
Hessaire coolers are highly recommended for outdoor use.
If used indoors, position cooler in front of window or open
door for fresh intake air. Ensure there is an open door or
window through which the air can exhaust from the room.
Clean media pads and tank frequently.
When shutting down unit, run without pump for 30 minutes
to properly dry media pads.
Prior to long term storage:
Drain tank and wipe clean
Dry and clean rigid media pads
1
Indoor Use:
Do Not Use
Garden Hose Attachment /
Continuous Fill Indoors.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Was this manual helpful?
About this manual
- Brand
- Hessaire
- Model
- MC37
- Document type
- Quick Guide
- Category
- Evaporative Cooler
- Language(s)
- English, Spanish
- Pages
- 8
- Format
Summary
Manual MC3761 Online ENG SPA 112721 Inspection After unpacking your cooler, carefully inspect for any dam- age that may have occurred during transit. Inspect for loose, missing or damaged parts. Note: wheels & hardware are located in a compartment on the bottom side of the cooler. Refer to pics ...
Manual MC3761 Online ENG SPA 112721 Maintenance Cleaning Cooler & Rigid Media Pads: The removable panel(s) & pads can be gently sprayed off to remove build up. A soft bristle brush can also be used. NEVER spray pads with water while cooler is in operation. Damage can occur to the motor and w...
Manual MC3761 Online ENG SPA 112721 # Parts MC37 M150/M160 MC61 M250/M260 1 Pump: M, V, & M150/M250, M160/M260 6036050 6060050 Pump for A model 6026050 - 2 Motor : M, V, & M150/M250, M160/M260 6375100 6615100 Motor: A model 6375101 - 3 Rigid Media Set CP370 CP610 4 Control: M model 6061069 6...