Hessaire MC18MT - User Manual
Hessaire MC18MT Evaporative Cooler – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Inspection; adapter are located on top of cooler upon opening box.; Quick Start; Note: Media pads may have a slight odor upon initial start; Features; Control Functions For MC18
- Page 3 – Maintenance; NEVER spray pads with water while cooler is in operation.; Removal Of Rigid Media:; Note: some pads may be held in place with pins (media; Removal Of Back Panel:; Visit Hessaire.com for additional maintenance tips and; Troubleshooting; Problem
- Page 4 – Parts; Cooler Parts; serial label will be needed for all warranty claims.; What is not covered:; cooler repairs regardless if the product is under warranty or not.
- Page 5 – Enfriador evaporativo móvil; Guía de uso y cuidado; La unidad debe estar en posición; APAGADA; antes de; RETIRAR; los paneles de acceso.; Consejos de operación
- Page 6 – Inspección; Instale ruedas; Inicio; Nota: las almohadillas de medios pueden tener un ligero ol-; Caracteristicas; no para uso en interiors)
- Page 7 – Mantenimiento; Eliminación de medios rígidos:; Quite los dos tornillos Phillips de la; Soluciones; Problema; Fuga de agua
- Page 8 – Parte; Partes; Garantía Hessaire
MC18 Online Manual Eng Spa 081621
INDEX
Safety Rules
……...
Quick Start
………..
Features
…………..
Maintenance
……...
Troubleshooting
….
Cooler Parts...
…....
Warranty
………..…
1
2
3
4
5
6
7
Mobile Evaporative Cooler
Use & Care Guide
MC18
1300 CFM
General Safety Precautions
Unit must be in
OFF
position and
UNPLUGGED
from
power receptacle before performing any maintenance /
service or before
REMOVING
access panels.
Make sure the electrical power source conforms to the re-
quirement of the evaporative cooler as well as local codes.
To reduce risk of fire or electrical shock, do not expose
electrical connections to water.
Do not touch electrically live components.
Ensure all power cords do not touch sharp edges, hot sur-
faces or chemicals. Immediately replace damaged parts.
Never leave unit unattended.
Continuous fill not to be used indoors or unattended.
Read and follow all instructions, cautions
and warnings. Failure to do so could result
in personal injury, death or property damage.
Operation Tips
Hessaire coolers are highly recommended for outdoor use.
If used indoors, position cooler in front of window or open
door for fresh intake air. Ensure there is an open door or
window through which the air can exhaust from the room.
Clean media pads and tank frequently.
When shutting down unit, run without pump for 30 minutes
to properly dry media pads.
Prior to long term storage:
Drain tank and wipe clean
Dry and clean rigid media pads
1
Indoor Use:
Do Not Use Garden
Hose Attachment.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
MC18 Online Manual Eng Spa 081621 Inspection After unpacking your cooler, carefully inspect for any dam- age that may have occurred during transit. Inspect for loose, missing or damaged parts. Note: wheels & hose adapter are located on top of cooler upon opening box. Contents: Evaporative Cooler...
MC18 Online Manual Eng Spa 081621 Maintenance Cleaning Cooler & Rigid Media Pads: The removable panel(s) & pads can be gently sprayed off to remove build up. A soft bristle brush can also be used. NEVER spray pads with water while cooler is in operation. Damage can occur to the motor and wil...
MC18 Online Manual Eng Spa 081621 # Parts MC18 1 Pump 6017050 2 Motor 6017051 3 Rigid Media Panel CP150 4 Control Knob & Switch 6017069 5 Caster Set (4 pcs) 6176100 6 Fan Blade 6017052 7 Float Valve Kit (float valve, hose adapter) 6018058 8 Manual fill door 6017076 9 Drain plug 6017081 Cooler Pa...