Page 2 - T4800 INSTALLATION INSTRUCTIONS; will produce an odor when the fireplace is used.; Table of Contents; SAFETY PRECAUTIONS; NEVER
34922 Rev B 2 12-01 T4800 INSTALLATION INSTRUCTIONS CAUTION: Do not expose the fireplace to the elements (i.e. rain, etc.) and keep the fireplace dry at all times. Wet insulation will produce an odor when the fireplace is used. Table of Contents Design and Installation Considerations ..................
Page 3 - DESIGN AND INSTALLATION CONSIDERATIONS
12-01 3 34922 Rev B T4800 INSTALLATION INSTRUCTIONS DESIGN AND INSTALLATION CONSIDERATIONS When selecting a location for your woodburning fireplace, it is important to evaluate a number of considerations. Modern construction techniques can create conditions that may not allow your chimney to draft p...
Page 4 - The Heatilator fireplace system consists of the following:; B. DESCRIPTION OF THE FIREPLACE SYSTEM
34922 Rev B 4 12-01 T4800 INSTALLATION INSTRUCTIONS WARNING! This fireplace and its components are designed to be installed and operated as a system. Any alteration to or substitution for items in this system, unless allowed by these installation instructions, will void the Underwrit- ers Laboratori...
Page 5 - C. SYSTEM COMPONENTS; Fireplace Components; Fireplace Dimensions
12-01 5 34922 Rev B T4800 INSTALLATION INSTRUCTIONS C. SYSTEM COMPONENTS 1. Fireplace Components Fireplace Dimensions Perception Glass Doors DP1348 DP1348B DP1348S Bi-Fold Glass Doors DM1348 DM1348B DM1348S # g o l a t a C : n o it p i r c s e D 0 0 8 4 T s p ir t S n o it c e t o r P h tr a e H d n...
Page 6 - AK14 - Outside Air Kit
34922 Rev B 6 12-01 T4800 INSTALLATION INSTRUCTIONS 2. Chimney Components The following pictures show only those chimney components which may be safely used with this fireplace. # g o l a t a C : n o it p i r c s e D 4 1 K A ) e c a l p e ri F h ti w d e d u l c n i( ti K ri A e d i s t u O A 5 K A ...
Page 9 - reduce the possibility of fireplace smoking or air flow reversal.; Fireplace Locations and Space Requirements
12-01 9 34922 Rev B T4800 INSTALLATION INSTRUCTIONS Figure 4 Corner Installation WARNING! Do not draw outside air from garage spaces. Exhaust products of gasoline engines are hazardous.Do not install outside air ducts such that the air may be drawn from attic spaces, basements or above the roofing w...
Page 11 - E. CHIMNEY REQUIREMENTS; Table 1; Using Offsets and Returns; but not less
12-01 11 34922 Rev B T4800 INSTALLATION INSTRUCTIONS E. CHIMNEY REQUIREMENTS When planning your fireplace location, the chimney construction and necessary clearances must be considered. The fireplace system and chimney components have been tested to provide flexibility in construction. The following...
Page 12 - Figure 8 - Chimney Height; Table 2; Number of Sections Required
34922 Rev B 12 12-01 T4800 INSTALLATION INSTRUCTIONS Figure 8 - Chimney Height S T N E N O P M O C Y E N M I H C F O T H G I E H r e z il i b a t S y e n m i h C 1 1 L S 4 3 / 4 " s r e c a p S p o t s e ri F 8 3 5 S F 0 0 4 5 S F 0 s n r u t e R / s t e s ff O 0 3 1 1 L S 1 ½ 4 " g n i h s ...
Page 13 - F. INSTALLATION OF FIREPLACE; Figure 9 - Positioning the Metal Strips; Positioning the Fireplace; Be sure to provide the; Placing the Protective Metal Hearth
12-01 13 34922 Rev B T4800 INSTALLATION INSTRUCTIONS F. INSTALLATION OF FIREPLACE WARNING! Before starting, do the following: 1. Wear gloves and safety glasses for protection.2. Keep hand tools in good condition. Sharpen cutting edges and make sure tool handles are secure.3. Always maintain the mini...
Page 15 - Attic Insulation Shield
12-01 15 34922 Rev B T4800 INSTALLATION INSTRUCTIONS WARNING! Maintain a minimum of 2 air clearance to all parts of the chimney system at all times! Fail- ure to maintain this 2 air clearance will cause a structure fire. CAUTION: Inner flue and outer liner sections cannot be dis- assembled once lo...
Page 16 - Figure 15 - Air Kit Handle Location; Be sure to maintain a 2 minimum air space
34922 Rev B 16 12-01 T4800 INSTALLATION INSTRUCTIONS Figure 14 - Ceiling/Attic Construction Figure 15 - Air Kit Handle Location 9. Marking the Exit Point of the Roof Locate the point where the chimney will exit the roof by plumbing down to the center of the chimney. Drive a nail up through the roof ...
Page 17 - Completion of the Enclosure
12-01 17 34922 Rev B T4800 INSTALLATION INSTRUCTIONS NOTE: Use only a noncombustible material to fin- ish the face of the fireplace below the level of the front standoffs. A noncombustible material such as USG MICORE CV230 Mineral Fiber Board, or USG DUROCK Cement Board is recommended for this purpo...
Page 18 - Figure 17 - Factory Built Hearth Extension
34922 Rev B 18 12-01 T4800 INSTALLATION INSTRUCTIONS Figure 17 - Factory Built Hearth Extension Figure 18 - Field Constructed Hearth Extension WARNING! Hearth extensions are to be installed only as illustrated to prevent high temperatures from occurring on concealed combustible materials. Hearth sea...
Page 20 - G. CONSTRUCTING A CHASE; Figure 20 - Chase Constructions
34922 Rev B 20 12-01 T4800 INSTALLATION INSTRUCTIONS G. CONSTRUCTING A CHASE Figure 20 - Chase Constructions Figure 21 - Chase Assembly 1. Materials a. T h e c h a s e i s c o n s t r u c t e d u s i n g f r a m i n g materials much the same as the walls in your h o m e . A v a r i e t y o f m a t e...
Page 21 - Figure 22 - Installing a TR11 Round Termination Cap
12-01 21 34922 Rev B T4800 INSTALLATION INSTRUCTIONS WARNING! Never install a single wall slip section or smoke-pipe in a chase structure. The higher temperature of this single wall pipe may radiate sufficient heat to combustible chase materials to cause a fire. WARNING! Detailed instructions for in...
Page 22 - H. OPERATING INSTRUCTIONS; General Information
34922 Rev B 22 12-01 T4800 INSTALLATION INSTRUCTIONS NOTE: Save and pass this instruction manual to subsequent home owners. The informa- tion provided is intended to notify and warn them about making unsafe future modifica- tions such as the addition of shelves or the use of unauthorized parts and r...
Page 23 - Proper Operating Positions of Bi-Fold Doors
12-01 23 34922 Rev B T4800 INSTALLATION INSTRUCTIONS Figure 25 Proper Operating Positions of Bi-Fold Doors WARNING! Burning wet, unseasoned wood can cause ex- cessive creosote accumulation. When ignited it can cause a chimney fire that may result in a serious house fire. CAUTION: When left closed wh...
Page 24 - uids to start or freshen up a fire in this fire-
34922 Rev B 24 12-01 T4800 INSTALLATION INSTRUCTIONS CAUTION: Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liq- uids to start or freshen up a fire in this fire- place. Keep all such liquids well away from the fireplace. NOTE: When first lighting your...
Page 25 - Figure 26 - Flue Draft
12-01 25 34922 Rev B T4800 INSTALLATION INSTRUCTIONS Figure 26 - Flue Draft Flue draft is measured as negative pressure in the c h i m n e y. T h e a m o u n t o f n e g a t i v e p r e s s u r e determines how strong the draft is. The draft is important because it draws the combustion air into the ...
Page 26 - I. MAINTENANCE INSTRUCTIONS; A chimney fire can permanently damage your; Clear Space Near the Fireplace
34922 Rev B 26 12-01 T4800 INSTALLATION INSTRUCTIONS I. MAINTENANCE INSTRUCTIONS WARNING! A chimney fire can permanently damage your chimney system. This damage can only be re- paired by replacing the damaged component parts. Chimney fires are not covered by the Lim- ited Warranty and Buyer Protecti...
Page 27 - Index
12-01 27 34922 Rev B T4800 INSTALLATION INSTRUCTIONS Index A Air Clearance 15, 17 Air Kit Handle Location 16 Ashes, Disposal of 26 Attic Insulation Shield 15 B Building Codes 2, 4 C Chase 20 Chase Top 8, 21 Chimney Assembling Sections Through the Roof 16 Checking the Assembly 15 Cleaning 26 Creosote...
Page 28 - Replacement Parts Advantage.
34922 Rev B 28 12-01 HEATILATOR WOODBURNING FIREPLACE Limited Warranty As part of its 20-YEAR BUYER PROTECTION PROGRAM AS PART OF ITS 20 YEAR BUYER PROTECTION PROGRAM (PROGRAM, HEARTH TECHNOLOGIES INC. (HTI) is pleased to offer a Limited Warranty and a Replacement Parts Advantage covering specif...