Page 2 - Listing Label Information/Location; The Heatilator gas; We recommend that you record the following pertinent; Homeowner Reference Information; NATURAL GAS; XXXXXXXX; Read this manual before installing or operating this appliance.
Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location ...
Page 3 - Safety Alert Key:; Used to address practices not related to personal injury.; Table of Contents; User Guide
3 Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in ...
Page 4 - B. Limited Lifetime Warranty; LIMITED LIFETIME WARRANTY; glass
Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 4 B. Limited Lifetime Warranty 4021-645C 12-29-10 Page 1 of 2 Hearth & Home Technologies Inc. LIMITED LIFETIME WARRANTY Hearth & Home Technologies Inc., on behalf of its hearth brands (”HHT”), exte...
Page 5 - This warranty is void if:
5 Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 B. Limited Lifetime Warranty (continued) 4021-645C 12-29-10 Page 2 of 2 WARRANTY CONDITIONS: 7KLVZDUUDQW\RQO\FRYHUV++7DSSOLDQFHVWKDWDUHSXUFKDVHGWKURXJKDQ++7DXWKRUL]HGGHDOHURUGLVWULEXWRU$OLVWRI ++7DXWKR...
Page 6 - Models; NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.; This appliance is tested and approved as either supplemen-; ori; Listing and Code Approvals; Standard Test Method for Behavior of Materials in a; shall be; National Electric Code ANSI/NFPA
Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 6 C. BTU Specifi cations MODELS: NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK LABORATORY: Underwriters Laboratories, Inc. (UL) TYPE: Vented Gas Fireplace Heater STANDARD: ANSI Z21.88-2009 CSA 2....
Page 7 - Operating Instructions; WARNING! DO NOT operate fi; A. Gas Fireplace Safety; WARNING; This appliance has been supplied with an integral barrier; HOT SURFACES; ammable
7 Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 2 Operating Instructions Figure 2.1 General Operating Parts B. Your Fireplace WARNING! DO NOT operate fi replace before read- ing and understanding operating instructions. Failure to operate fi replace acc...
Page 8 - E. Fixed Glass Assembly; barrier to prevent direct contact with the; F. Remote Controls, Wall Controls and Wall; G. Before Lighting Fireplace; have a; RED OR BLACK IGNITOR BUTTON
Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 8 C. Clear Space WARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.2. Avoid placing candles and other heat-sensitive obj...
Page 9 - life, remove them when using the transformer.; LIGHTING; NOT FOR USE; GAS; on the; WHAT TO DO IF YOU SMELL GAS; DO NOT CONNECT LINE VOLT-; Hot; Also Certifi ed for Installation in a; Final inspection by
9 Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 H. Lighting Instructions (IPI) The IPI system may be operated with two D-cell batteries. When using batteries, unplug the transformer. To prolong battery life, remove them when using the transformer. 1. ...
Page 10 - DO NOT CONNECT 110 VAC TO
Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 10 1. Turn off all electric power to the appliance if ser- vice is to be performed. 2. Open control access panel. 3. Move switch to “OFF” position. 4. Push in gas control knob slightly and turn clock- wise...
Page 11 - J. After Appliance is Lit; ISSUE; ames
11 Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 Initial Break-in Procedure• The appliance should be run three to four hours continuously on high. • Turn the appliance off and allow it to completely cool.• Remove fi xed glass assembly. See Section 12.H...
Page 12 - Glass Cleaning; Tools Needed; CAUTION! Handle fi xed glass assembly with care.; Note; Maintenance and Service; The appliance should be; Tools needed; Remote Control; Any safety screen or guard removed for servicing must be
Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 12 Glass Cleaning Frequency: Seasonally By: Homeowner Tools Needed : Protective gloves, glass cleaner, drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care. Glass is breakab...
Page 13 - Venting; ashing remains; Gasket Seal and Glass Assembly Inspection
13 Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 Venting Frequency: Seasonally By: Homeowner Tools needed: Protective gloves and safety glasses. • Inspect venting and termination cap for blockage or obstruction such plants, bird nests, leaves, snow, d...
Page 14 - Burner Ignition and Operation; DO NOT; ame sense
Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 14 Figure 3.1 Standing Pilot Flame Patterns Burner Ignition and Operation Frequency: Annually By: Service Technician Tools needed: Protective gloves, vacuum cleaner, whisk broom, fl ashlight, voltmeter, ind...
Page 15 - A. Typical Appliance System; Illustrations and photos re; Getting Started; Installer Guide
15 Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 A. Typical Appliance System NOTICE: Illustrations and photos re fl ect typical installations and are for design purposes only. Illustrations/diagrams are not drawn to scale. Actual product may vary from ...
Page 16 - Read all of the instructions before starting the instal-; C. Tools and Supplies Needed; Hearth & Home Technologies disclaims any responsibility for,; Any such action may cause a fi re hazard.; DO NOT use this appliance if any part has been under; Improper installation, adjustment, alteration, service or
Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 16 B. Design and Installation Considerations Heatilator gas inserts are designed for installations into solid fuel masonry or factory built fi replaces that have been installed in accordance with the Nation...
Page 17 - Fireplace Size Requirements; A. Minimum Fireplace Opening; Provide adequate
17 Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 5 Fireplace Size Requirements Figure 5.1 Fireplace Opening In addition to these dimensions, also reference Clearances and Mantel Projections (Section 5.B). E D C I B A G H F MINIMUM FIREPLACE SIZE Locat...
Page 18 - B. Mantel and Wall Projections; • Use leveling legs to raise insert minimum 1/4 inch (6 mm); Alternate Unit Width; TOP VIEW
Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 18 B. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as speci fi ed. Framing or fi nishing material closer than the minimums listed must be construct-...
Page 19 - A. Vent Termination Minimum Clearances; Termination Locations; pack air space with insulation or
19 Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 A. Vent Termination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 ................................................
Page 20 - Installation Preparation; A. Inspection and Cleaning
Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 20 7 Installation Preparation Prepare the existing solid fuel masonry or factory built non-combustible fi rebox for installation. A. Inspection and Cleaning Prior to installing the gas insert:• Have the chi...
Page 21 - B. Venting Components; Installing Vent Pipe and Appliance; C. Connecting Vent Pipe; • May impair safe operation of this appliance or other; Description; Minimum Vertical Run Length 10 ft.; CAUTION! ALL vent specifi cations MUST be followed.
21 Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 B. Venting Components CAUTION! Risk of Cuts/Abrasions/Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. The vertical vent termination system in...
Page 22 - ance; the
Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 22 Figure 8.2 CUT AND BEND FLASHING AS NEEDED TO FIT CHIMNEY SEALANT ADHESIVE • Trim chimney top plate to minimize excess overhang or bend over fl ue tile (see Figure 8.2). • Place 3/8 inch bead of 300º F s...
Page 23 - F. Installing Adaptor and Termination Cap; For installation of termination cap see minimum vent; Masonry; Wear protective gloves and safety glasses during instal-; Damper Flashing Kit; : Damper may have to be removed to use this kit.; system REQUIRES this insulation.; OR
23 Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 F. Installing Adaptor and Termination Cap For installation of termination cap see minimum vent heights for various pitched roofs (see Figure 8.4) . To install adaptor see Figure 8.5. Roof Pitch H (Min.)...
Page 24 - Gas Information; • If substituting for these components, please consult; D. High Altitude Installations; Gas Pressure
Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 24 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualifi ed technician (NFI certifi ed or factory-trained) using Hearth & Home Techn...
Page 25 - B. Standing Pilot Ignition System Wiring; DOES NOT; built; A. Wiring Requirements; National Electric Code; Electrical Information; C. IntelliFire Ignition System Wiring; WARNING! Risk of Shock or Explosion! DO NOT
25 Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 B. Standing Pilot Ignition System Wiring • The standing pilot ignition system wiring DOES NOT require a 120 VAC supply to operate. • To power appliance with 120VAC to operate a fan or remote control, an...
Page 27 - D. Optional Accessories Requirements; Label all wires prior to dis-
27 Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 Figure 10.5 Fan Wiring Diagram BLOWERS BLOWER RECEPTACLE BLKGRNBLK BLKGRNBLK WHT GRN BLK BLK GRN WHT BLK BLK BLK BLK PLUG INTO 120V EXISTING OUTLET TEMPERATURE SENSOR SWITCH VARIABLE SPEED CONTROL DC RE...
Page 29 - Finishing; A. Mantel and Wall Projections
29 Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 11 Finishing A. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as speci fi ed. Framing or fi nishing material closer than the minimums listed must ...
Page 30 - WARNING! Risk of Fire and Electric Shock!; E. Place the Lava Rock; Appliance Setup; DO NOT place lava rock on
Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 30 A. Remove Glass Assembly See Section 12.H. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the fi rebox. C. Clean the Appliance Clean/vacuum any sawdust that may have...
Page 31 - G. Install the Log Assembly; #2 forward until it comes into contact with the grate tine.; TINES
31 Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 G. Install the Log Assembly Log Set Assembly: LOGS-NDI30 Models: NDI30, NDI30-SP Log #1 (SRV2226-701) Position Log #1 as shown in Figure 2. Note additional placement instructions in Figure 1. Set the re...
Page 32 - log set properly installed.; POSITIONED ON; end of Log #3 forward until it comes into contact with the grate tine.
Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 32 Log #4 (SRV2226-703) : Position Log #4 as shown in Figure 7. See Figure 1 and Figure 2 for additional details. Place the top end of log #4 on the fl at spot of Log #1. Position the forked end of Log #4 a...
Page 33 - Position Log #1 as shown in Figure 3. Note additional
33 Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 G. Install the Log Assembly Log Set Assembly: LOGS-NDI35 Models: NDI35, NDI35-SP CAUTION: Logs are fragile, handle with care. Log #1 (SRV2224-701) Position Log #1 as shown in Figure 3. Note additional r...
Page 35 - I. Air Shutter Setting; H. Fixed Glass Assembly; DO NOT operate; Removing Fixed Glass Assembly; Air Shutter Settings; NG
35 Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 I. Air Shutter Setting Air shutter settings should be adjusted by a qualifi ed ser- vice technician at the time of installation. The air shutter is set at the factory for minimum vertical vent run. Adjus...
Page 36 - A. Standing Pilot Ignition System; Troubleshooting; arrange a service call by a qualifi ed technician.; Symptom; there is no burner
Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 36 A. Standing Pilot Ignition System 13 Troubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, t...
Page 38 - B. IntelliFire Ignition System; there is no noise or
Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 38 B. IntelliFire Ignition System Symptom Possible Cause Corrective Action 1. Pilot won’t light. The ignitor/module makes noise, but no spark. A. Incorrect wiring. Verify “S” wire (white) for sensor and “I...
Page 39 - ame
39 Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 Symptom Possible Cause Corrective Action 4. Pilot lights but contin- ues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot fl ame has been lit, fl ame rectifi cati...
Page 40 - Reference Materials; A. Appliance Dimension Diagram
Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 40 14 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. Figure 14.1 Appliance Dimensions A H B C D E I G F N M L K J O R Q P S GAS LINE ...
Page 41 - B. Vent Kits Components; feet and 4 feet respectively. Includes: two liners, termination; GK to connect collinear fl ex vent to SL-D vent pipe to
41 Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 B. Vent Kits Components Direct Vent Flex Liner Kits (see Figure 14.2)LINK-DV30B: Masonry 3 inch fl ex liner kit. Expands to 30 feet. Includes: two liners, termination cap, fl ashing, and link adapter.LINK...
Page 42 - D. Contact Information; For the location of your nearest Heatilator dealer,; DO NOT DISCARD THIS MANUAL; NOTICE
Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11 48 Heatilator, a brand of Hearth & Home Technologies Inc. 7571 215 th Street West, Lakeville, MN 55044 www.heatilator.com D. Contact Information Please contact your Heatilator dealer with any questions...