Hayward W3SP2607X10 - User Manual
Hayward W3SP2607X10 Pump – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 4 – General Information; Introduction; Heat resistant, industrial size ceramic seal.; Product Specifications; Pump; PUMP PART
- Page 5 – Allow pump inlet height to be as close to water level as possible.; Risk of Electric Shock; Fire Hazard. Match supply voltage to motor nameplate voltage.
- Page 6 – NOTICE –; A licensed electrician must do all wiring.; – Separation Hazard; WARNING
- Page 7 – Maintenance; Storing Pump for Winterization; Electrical Hazard
- Page 8 – Shaft Seal Change Instructions; death. To avoid, turn OFF power to motor before servicing pump.; Replacing the Impeller and Diffuser; Place the; diffuser; over the; impeller; onto the; seal plate
- Page 9 – Replacement Parts; Parts Diagram
- Page 10 – Troubleshooting; Motor Will NOT Start – Check For:
- Page 11 – Noisy Pump – Check For:; HAYWARD
- Page 12 – Su; uper Pum; mp; USE ONLY H; HAYWARD GEN; NUINE REPLAC; Wa; TS; arranty C
ISSPSERIES Rev D
USE ONLY HAYWARD GENUINE REPLACEMENT
PARTS
1
Super Pump
®
Series
Owner’s Manual
IMPORTANT SAFETY INSTRUCTIONS
The Hayward Super Pump
®
is specifically engineered for the demanding requirements of today’s in-ground swimming
pool/spa that is equipped with large capacity filters, heaters, and pool cleaning equipment. The Super Pump
®
is a self-
priming pump that incorporates a seal and impeller design that will provide many years of efficient, dependable, corrosion-
free service. The advanced design provides superior performance while reducing maintenance requirements.
Basic safety precautions should always be followed, including the following: Failure to follow instructions
can cause severe injury and/or death.
This is the safety-alert symbol. When you see this symbol on your equipment or in this manual, look for
one of the following signal words and be alert to the potential for personal injury.
WARNING
warns about hazards that could cause serious personal injury, death or major property
damage and if ignored presents a potential hazard.
CAUTION
warns about hazards that will or can cause minor or moderate personal injury and/or
property damage and if ignored presents a potential hazard. It can also make consumers aware of
actions that are unpredictable and unsafe.
The NOTICE label indicates special instructions that are important but not related to hazards.
Hayward Pool Products
620 Division Street, Elizabeth, NJ 07207
Phone: (908) 355-7995
www.hayward.com
Contents
Product Specific Warnings………2
Introduction……….………………..…4
Installation……….……………..….….7
Shaft Seal Replacement..………..8
Replacement Parts………….……….9
Trouble Shooting………….…..……10
Warranty…………………………………11
Registration ……………………………12
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 4 General Information Introduction This manual contains information for the proper installation and operation of the Hayward Super Pump ® Series. The instructions in this manual MUST be followed precisely. Failure to install according to defined instruction...
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 5 Pump Mounting Install pump on a firm, level base or pad to meet all local and national codes. Fasten pump to base or pad with screws or bolts to reduce vibration and stress on pipe or hose joints. The base MUST be solid, level, rigid, and vibration free. ...
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 6 Use copper conductors only. ELECTRICAL GUIDE – 60 CYCLE MOTORS – SINGLE PHASE MOTOR VOLTS CIRCUIT BREAKER RATINGS-AMPS BRANCH FUSETRON RATINGS-AMPS RECOMMENDED WIRE SIZE 0-50’ KW HP .37 1/2 115 15 15 No. 14 .55 3/4 115 230 15 10 15 6.25 No. 14 No. 14 .75 ...