Table of Contents:

  • Page 3 – USE ONLY HAYWARD GENUINE REPLACEMENT PARTS; SAVE THESE INSTRUCTIONS
  • Page 4 – Product Specifications; Quick connect intake and discharge pipe connection.; Installation Instructions
  • Page 5 – Pump Mounting; Hayward recommends a minimum clearance around the pad of 18” to; Plumbing; All electrical wiring should be performed by a qualified; WARNING; WARNING; Voltage; WARNING; Permanently ground motor
  • Page 6 – Selecting Pump’s Discharge Position (4 Steps); Disengage and lift off strainer cover.; Priming Pump; Open all valves before starting system.; Figure 1
  • Page 7 – Storage/Winterization; Purging the system with compressed air can cause components to; Allowing the pump to freeze will void the warranty.; CAUTION; motor before draining pump.; Start-Up for Winterized Equipment
  • Page 8 – Shaft Seal Change Instructions; Hayward Dealer or service center if you have any questions.
  • Page 9 – Troubleshooting; Motor Will NOT Start – Check For:; Mechanical binding and electrical overload.; Motor Hums, But Does NOT Start – Check For:; Centrifugal switch stuck in OPEN position.; Pump Won’t Prime; Check voltage to ensure that the motor is rotating at full RPM’s.
  • Page 10 – Troubleshooting Continued:; Noisy Pump – Check For:; Air leak in suction piping causing rumbling in pump.; Maintenance; Keep motor clean. Insure air vents are free from obstruction.
  • Page 11 – Parts Diagram; Description
  • Page 12 – USE ONLY; HAYWARD; WW; Y HAYWARD GE; Pool Pr; ENUINE REPLA; roducts Li; ACEMENT PAR; mited Wa; RTS; rranty
Loading the manual

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

1

PowerFlo Matrix

®

Pump

Owner’s Manual

The Hayward PowerFlo Matrix Pump Series is specifically engineered for the demanding requirements of
today’s above-ground swimming pools. The advanced design reduces maintenance requirements while

providing superior performance.

IMPORTANT SAFETY INSTRUCTIONS

Contents

Warnings………………………………2

Introduction……….…………….…..4

Installation……….……………..……4

Storage & Winterization...………7

Seal Replacement………….………8

Troubleshooting .………….…….…9

Replacement Parts………..………11

Warrantee & Registration ………12

Basic safety precautions should always be followed, including the following: Failure to follow instructions

can cause severe injury and/or death.

This is the safety-alert symbol. When you see this symbol on your equipment or in this manual, look for

one of the following signal words and be alert to the potential for personal injury.

WARNING warns about hazards that could cause serious personal injury, death or major property

damage and if ignored presents a potential hazard.

CAUTION warns about hazards that will or can cause minor or moderate personal injury and/or property

damage and if ignored presents a potential hazard. It can also make consumers aware of actions that are

unpredictable and unsafe.

The NOTICE label indicates special instructions that are important but not related to hazards.

Hayward Pool Products

620 Division Street, Elizabeth, NJ 07207

Phone: (908) 355-7995

www.hayward.com

ISSP1591 Rev H

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - USE ONLY HAYWARD GENUINE REPLACEMENT PARTS; SAVE THESE INSTRUCTIONS

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 3 WARNING – Risk of Electric Shock. All electrical wiring MUST be in conformance with applicable local codes, regulations, and the National Electric Code (NEC). Hazardous voltage can shock, burn, and cause death or serious property damage. To reduce the ris...

Page 4 - Product Specifications; Quick connect intake and discharge pipe connection.; Installation Instructions

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 4 Product Specifications Dimensions General Information Introduction This manual contains information for the proper installation and operation of the Hayward PowerFlo Matrix ® pump. WARNING - Read and follow all instructions in this owner’s manual and on t...

Page 5 - Pump Mounting; Hayward recommends a minimum clearance around the pad of 18” to; Plumbing; All electrical wiring should be performed by a qualified; WARNING; WARNING; Voltage; WARNING; Permanently ground motor

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 5 Pump Mounting Fasten pump to base or pad with screws or bolts to reduce vibration and stress on pipe or hose joints. Hayward recommends a minimum clearance around the pad of 18” to allow adequate access for servicing pump and piping. Plumbing Installing u...