Harman The Harman Accentra Pellet Insert - Manual

Harman The Harman Accentra Pellet Insert

Harman The Harman Accentra Pellet Insert – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
Page: / 37

Table of Contents:

  • Page 2 – Introduction; Harman Stov e Company; Table of Contents; SERIAL NUMBER
  • Page 3 – Starting First Fire; to desired room; Automatic Start Up; WARNING
  • Page 4 – Automatic Ignition/Operation; Stove Temperature M ode
  • Page 5 – Manual Start Up; to “OFF” and; Warning
  • Page 6 – NOTE: During the use of this mode, if you keep; Manual Ignition/Operation; Manual Stove Temperature M ode
  • Page 7 – ESP Control; Status light error messages:; Indicates control board self diagnostic fail-; Blinks; : Indicates that the control has calculated
  • Page 8 – Installation: Removing unit from skid; How to Reduce the Weight for Installation; Note: Removal of the cast hopper lid itself is; The cast top and lid assembly bolt down bars:
  • Page 9 – Installation; How to Reduce the Weight for Installation, cont'd; ppr oximatle ly; Removing the Heat Exchanger Covers; Lifting tab
  • Page 10 – T he mo u nt in g f r a me /s ur r o un d; Beginning Installation
  • Page 11 – • Cut the tyraps looping the cord to the left; DO; Connecting the cord retainer to the w ing; Ground; Optional Wing Extensions
  • Page 12 – Connecting the room sensor as a return air sensor; Insert the sensor end of the wire from the rear of the; leveling bolt holes
  • Page 13 – Flue Pipe Stub Assembly; The unit comes standard with the largest for use with 4”; Ash lip; Tw isted tie w ire; T his insulation must
  • Page 14 – Connecting the ground from the w ing to the; The green wire with a female terminal is the stove; If service is performed on this stove, this ground; Lasered hinge pin pivoting point
  • Page 15 – Connecting the Room Sensor; of the room sensor wires.; Hopper Seal; Make sure the hopper lid is open to install unit, then; Docking Gasket
  • Page 16 – • Note: The two spring latches on the bottom; Spring Latch; Fit cast
  • Page 17 – Wiring; socket; Log Set Option
  • Page 18 – required; check and record the high and low draft readings.; Low Draft Voltage Adjustment; Draft Meter bolt hole location
  • Page 19 – CAUTION; Mobile Home Installation; CAUTION
  • Page 20 – Venting
  • Page 21 – Outside Air; Outside air is optional (not required) except in; HRV; W hen installing in a house with a Heat Reclaim-; Vent Pipe
  • Page 22 – #2 Installing into an existing
  • Page 23 – #3 Installing into an existing; KEEP COMBUSTIBLES (SUCH AS; MUST BE SEALED
  • Page 24 – W hen installing the Accentra Insert into a factory; most
  • Page 25 – AFTER THE INSTALLATION IS COMPLETED; Harman Accentra Insert Zero Clearance Cabinet; See your dealer for part details; Harman Mantel System; Accentra Insert Zero Clearance Cabinet; B e s u re t o u s e a p -; Harman Zero
  • Page 26 – Requirements for Terminating the Venting; any other appliance must be a minimum of 48”.; w ith outside air installed, 6 feet; exterior combustibles such as mulch is 36” as mea-
  • Page 27 – Maintenance - Cleaning Glass on View Door; such as cotton or paper towels.; Disposal of ashes; Glass Gasket
  • Page 28 – Burn Pot Cleaning and Maintenance; The ignite r is made to be removable f or; DANGE R; m ust always be pulled to the rear of the; Maintenance - Burn Pot; Burn pot igniter
  • Page 29 – Maintenance - Cleaning; Cleaning the Heat Exchanger; Note: The unit “must be cold” before using anything; Cleaning the Heat Exchanger tubes; Note: The brust will only extend into the fight side tube
  • Page 30 – Feeder Chamber; To remove the feeder cover:
  • Page 31 – is; ra
  • Page 33 – Specifications
  • Page 34 – Accentra Insert Wiring Diagram
  • Page 35 – Accentra Insert Feeder Parts
  • Page 36 – Accentra Insert Parts List
  • Page 37 – Harman Gold Warranty; replace the product as described below.
Loading the manual

SAFETY NOTICE

PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW ROOM HEATER. FAILURE TO
FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.

FOR USE IN THE U.S. AND CANADA. SUITABLE FOR INSTALLATION IN MOBILE HOMES

IF THIS HARMAN ACCENTRA PE LL ET INS ERT IS NOT PROP ERLY INSTALLED, A HOUSEFIRE MAY RESULT. FOR
YOUR SAFETY, FOLLOW INSTALLATION DIRECTIONS.

CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION
REQUIREMENTS IN YOUR AREA.

CONTACT YOUR LOCAL AUTHORITY (SUCH AS MUNICIPAL BUILDING DEPARTMENT, FIRE DEPARTMENT, FIRE
PREVENTION BUREAU, ETC.) TO DETERMINE THE NEED FOR A PERMIT.

CETTE GUIDE D'UTILISATION EST DISPONIBLE EN FRANCAIS. CHEZ VOTRE CONCESSIONNAIRE DE HARMAN STOVE
COMPANY.

SAVE THESE INSTRUCTIONS.

The Harman Accentra Pellet Insert

Installation & Operating Manual

R3

“Ce manuel est disponible en Français sur demande”

Evaluation notes were added to the output document. To get rid of these notes, please order your copy of ePrint IV now.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Introduction; Harman Stov e Company; Table of Contents; SERIAL NUMBER

3 Introduction Harman Stov e Company 352 Mountain House Road Halifax, PA 17032 [email protected] [email protected] Table of Contents Automatic Operation 4 Manual Operation 6 ESP Control 8 Assembly & Installation 9 Venting 21 Maintenance 28 Trouble-Shooting 33 Specifications 34 Wiring D...

Page 3 - Starting First Fire; to desired room; Automatic Start Up; WARNING

4 Starting First Fire Igniter Switch to"AUTO" (up position) Make sure the unit is plugged into a 120 VAC,60 HZ electrical source. The power light shouldbe the only light lit. 1. Turn Mode Selector to "OFF". 2. Fill hopper with pellets. 1 3. Clean burn pot with scraper, if necessary. ...

Page 4 - Automatic Ignition/Operation; Stove Temperature M ode

5 The Accentra Insert is more than just automatic ignition, it is also automatic temperaturecontrol. The automatic system will allow the fire size to be adjusted to match the heatingneeds and even put the fire out if necessary. If heat is needed after the fire is out, theAccentra Insert will automat...

Other Harman Models

All Harman Other