Page 2 - Ne pas entreposer ni utilizer d’essence ni; Ne pas tenter d’allumer d’appareil.; INSTALLATEUR: Laissez cette notice avec l’appareil.
2 AVERTISSEMENT : Assurez-vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d’incindie ou d’explosion ou pour éviter tout dommage matériel, toute blessure ou la mort. - Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs ou liquides inflammables...
Page 3 - TABLE OF CONTENTS; IMPORTANT
3 TABLE OF CONTENTS IMPORTANT SAFETY INFORMATION 4 SPECIFICATIONS 5 INSTALLATION 6 MASSACHUSETTS REQUIREMENTS 7 VENTING 8 ASSEMBLY 14 LIGHTING AND OPERATION 23 REMOTE CONTROL HANDSET OPERATION & PROGRAMMING 26 MAINTENANCE 28 PARTS LIST 30 WARRANTY 31
Page 4 - IMPORTANT SAFETY INFORMATION; or the
4 IMPORTANT SAFETY INFORMATION The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 or the Canadian Installation Code, CAN/CGA B149. A manufactured home (USA only) or mobile home OEM installation must conform with the Manufact...
Page 5 - SPECIFICATIONS; MAIN BURNER
5 SPECIFICATIONS MAIN BURNER Natural Gas Propane (LP) Input Rating-Btu/hr 36000 36000 Min. Input-Btu/hr 23000 23000 Orifice-DMS #34 #50 COOKING BURNER Input Rating-Btu/hr 12000 12000 Min. Input-Btu/hr 3500 3500 Orifice-DMS #52 #58 GAS SUPPLY Manifold Pressure 4.5”w.c./1.3kPa 10.0”w.c./2.5kPa Min. Su...
Page 6 - INSTALLATION
6 INSTALLATION MINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTION Stove to Left Side Wall 6” (150mm) Stove to Corner Wall 6” (150mm) Stove to Right Side Wall 6” (150mm) Stove to Ceiling 30” (760mm) Stove to Rear Wall 6” (150mm) Stove to 10” Deep Mantel 30” (760mm) Max. Alcove Depth 24” (610mm) Several i...
Page 7 - REQUIREMENTS FOR THE COMMONWEALTH OF MASSACHUSETTS; AmeriVent Direct
7 INSTALLATION The gas stove is shipped with a flexible connector that has a 1/2” NPT female connection. The gas supply piping should have a separate gas shutoff valve and a 1/8” NPT plugged tapping upstream of the valve. The stove and its main control valve must be disconnected from the gas supply ...
Page 8 - VENTING; E1⁄2
8 VENTING The FireLuxe Gas Stove has been tested and listed for installation with 4” X 6 5/8” Simpson DuraVent GS, AmeriVent Direct, Security Secure Vent and Selkirk DT direct venting components. For specific installa- tion requirements, follow the installation instructions included by the venting m...
Page 10 - VERTICAL RISE IN FEET
10 VENTING VERTICAL RISE IN FEET HORIZONT A L RUN IN FEET NATURAL GAS VENTING IF Y O U R VEN TI N G CO NF IG UR A - TION F A L L S A B OVE T H IS DOT- TED L IN E , SEE P A GE 12
Page 12 - VENTING INTO AN EXISTING MASONRY OR CLASS A CHIMNEY
12 VENTING PLEASE NOTE: If your specific venting configuration falls in a box in the venting charts (on pages 10 & 11) that is above the dotted line ( ), you must use one of the approved direct vent venting systems that utilizes a stainless steel inner liner. The dotted line corresponds to a tot...
Page 13 - VENT TERMINAL CLEARANCES
13 VENT TERMINAL CLEARANCES VENTING Venting terminals shall not be recessed into a wall or siding.
Page 14 - ASSEMBLY; UNPACKING AND PLACING THE FIRELUXE
14 ASSEMBLY UNPACKING AND PLACING THE FIRELUXE By now, you will have removed the shipping carton from the base pallet. The FireLuxe is shipped on spe-cially designed shipping supports that keep the weight of the stove off the legs to avoid damaging them dur-ing transit. Cut the strapping that secure...
Page 15 - LOGS AND EMBERS
15 ASSEMBLY LEFT REAR LOG RIGHT REAR LOG LEFT REAR LOG RECESS RIGHT REAR LOG RECESSES LEFT FRONT LOG RECESS RIGHT FRONT LOG RECESS PINS LOGS AND EMBERS Slide the logs and packing out of the firebox and set on the floor. Carefully unpack each of the four logs and three loose ember pieces. The logs an...
Page 16 - LEFT FRONT LOG
16 ASSEMBLY Place the left front log next. Again, there is a recess on the burner top that corresponds to the shape of the flat base of the log. Place the left end of the log in the recess and rest the right end on the left rear log using the illustration below as a guide. Place the right front log ...
Page 17 - Top or Rear Vent
17 ASSEMBLY When correctly placed, the logs and embers will look like the illustration below. LATCHING DETAIL- PULL FORWARD AND DOWN TO HOOK LATCH OVER GLASS FRAME After the logs and embers have been placed, the next step is to replace the glass panel and frame. Carefully pick up the glass and glass...
Page 18 - BRASS DIFFUSER RING
18 ASSEMBLY It is now time to install the ashlip on the stove front and to install the stove front and stove top. The ashlip is secured to the front using two brackets and four 1/4 – 20 hex head bolts. With the front facing down on a padded surface, align the mounting bosses on the ashlip with the m...
Page 19 - BATTERY INSTALLATION OR REPLACEMENT; Refer to the illustrations below.
19 ASSEMBLY The remote control handset is powered by a 9-volt battery. There is a low battery indicator on the handset display panel. To replace the battery, remove the access cover from the rear of the handset and unsnap the old battery. Replace with a high quality long-life alkaline battery and re...
Page 20 - GAS CONNECTION
20 ASSEMBLY The main heating valve battery pack is located at the center rear of the stove. A removable valve access panel covers the valve components and simply lifts up and off the stove back. The batteries are located in the control module next to the actual valve. The battery access cover lifts ...
Page 23 - LIGHTING AND OPERATION
23 FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. THIS APPLIANCE HAS TWO SEPARATE BURNER AND GAS CONTROL SYSTEMS. ONE SYS-TEM IS FOR THE MAIN HEATING BURNER AND TH...
Page 24 - TO TURN OFF GAS TO MAIN BURNER; for more information.; TO TURN OFF GAS TO COOKING BURNER; Turn the MAN-knob to the ON, full counterclockwise
24 LIGHTING AND OPERATION 1. To turn the cooking burner off, turn the knob to the OFF, full clockwise position. TO TURN OFF GAS TO MAIN BURNER 1. Press the OFF button on the remote (if available). 2. Turn the main valve knob to the OFF full clockwise position. LIGHTING INSTRUCTIONS - COOKING BURNER ...
Page 25 - COOKING BURNER OPERATION
25 LIGHTING AND OPERATION COOKING BURNER OPERATION The cooking burner on your FireLuxe functions like a cooking burner on any conventional kitchen range. A battery-powered flame-sensing automatic ignition system lights the burner when you depress the control knob and rotate counterclockwise to the H...
Page 26 - PILOT FLAME ADJUSTMENT; Turn the adjustment screw clockwise to de-
26 LIGHTING AND OPERATION REMOTE CONTROL HANDSET OPERATION AND PROGRAMMING Flame Height Adjustment PILOT FLAME ADJUSTMENT The pilot flow is factory set to maximum. The pilot flame should envelope 3/8” to 1/2” of the thermo-couple. See the illustration above. The adjustment screw can be reached throu...
Page 28 - MAINTENANCE; REPLACING THE GLASS
28 MAINTENANCE A qualified service agency should conduct an annual inspection and maintenance of your FireLuxe includ-ing the overall installation and venting to keep it running safely. The following procedures should be per-formed only by a qualified service person. The gas supply should be turned ...
Page 29 - vent them from baking on.; Check the blower during the annual service appointment
29 MAINTENANCE INSPECTING THE VENTING An inspection of both the inner and outer vent pipes and the vent terminal should be made as part of the an-nual service appointment. The venting must have no blockage and be in good repair. The vent manufac-turer’s instructions may provide specific details on v...
Page 30 - PARTS LIST
30 PARTS LIST *This is a quick response thermocouple. Replace it only with Part No. 3-40-09906
Page 31 - HARMAN GOLD WARRANTY
31 HARMAN GOLD WARRANTY 6 YEAR TRANSFERABLE LIMITED WARRANTY (Residential) 1 YEAR LIMITED WARRANTY (Commercial) Harman Stove Company warrants its products to be free from defects in material or workmanship, in normal use and service, for a period of 6 years from the date of sales invoice and for mec...