Page 2 - Disclaimer
Disclaimer Hand Held Products, Inc. d/b/a HHP (“HHP”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult Hand Held Products to determine whether any such changes have been made. The in...
Page 3 - Statement of Agency Compliance; FCC Class B Compliance Statement
Statement of Agency Compliance The IT2020/IT5620 system meets or exceeds the requirements of all applicable standards organizations for safe operation. However, as with any electrical equipment, the best way to ensure safe operation is to operate them according to the agency guidelines that follow. ...
Page 4 - Canadian Compliance; CE Compliance
If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user may find the following booklet helpful: “Something About Interference.” This is available at FCC local regional offices. Hand Held Products, Inc. is not responsible for...
Page 5 - Bluetooth Qualified Product
Hand Held Products shall not be liable for use of our product with equipment (i.e., power supplies, personal computers, etc.) that is not CE marked and does not comply with the Low Voltage Directive. Regulatory Approvals for Bluetooth Radio Devices RF devices are designed to comply with the most cur...
Page 6 - Solids and Water Protection
UL and cUL Statement UL listed UL1950 and CSA 22.2 No.950. cUL listed UL1950 and CSA 22.2 No 950. TÜV Statement TÜV or GS marked to EN60950 and EN60825-1. C-Tick Statement Conforms to AS/NZS 3548. C-Tick number: N10410. Mexico Patents Please refer to the IT5620 packaging for patent information. Soli...
Page 7 - Required Safety Labels
Page 9 - Chapter 1 - Getting Started; Connecting the Base When Powered by Host; Table of Contents
i Chapter 1 - Getting Started About This Manual ............................................................... 1-1Unpacking the System .......................................................... 1-2Models .................................................................................. 1-2Cordless ...
Page 10 - ii; Chapter 2 - Terminal Interfaces
ii Connecting the Base with USB ........................................... 1-18 IBM SurePos ................................................................ 1-19USB PC or Macintosh Keyboard.................................. 1-19USB HID ..................................................................
Page 11 - iii; Chapter 4 - Data Editing
iii Good Read Delay .................................................................. 3-3 User-Specified Good Read Delay ................................... 3-3 Scanner Trigger Modes ......................................................... 3-4 Manual/Serial Trigger, Low Power ........................
Page 12 - iv; Chapter 5 - Data Formatting
iv Chapter 5 - Data Formatting Data Format Editor Introduction ........................................... 5-1 To Add a Data Format .................................................... 5-1Other Programming Selections....................................... 5-2Data Format Editor Commands ................
Page 15 - vii; Chapter 10 - Serial Programming Commands
vii Temporary Visual Menu 2003 Configuration ....................... 8-2 Chapter 9 - Visual Menu 2003 Visual Menu 2003 Introduction ............................................ 9-1 Installing Visual Menu 2003 from the Web ................... 9-1 Chapter 10 - Serial Programming Commands Conventions ....
Page 16 - viii; Appendix A
viii Appendix A Symbology Chart ................................................................. A-1ASCII Conversion Chart (Code Page 1252) ........................ A-2Code Page Mapping of Printed Bar Codes .......................... A-4
Page 17 - Getting Started; About This Manual
IMAGETEAM™ 2020/5620 System Manual 1 - 1 1 Getting Started The IMAGETEAM 5620 cordless scanning system consists of one IT2020 base and one IT5620 Cordless Linear Imager. The IT5620 marks a new performance level for hand held scanners. The IT5620 is powered by Hand Held Products’ Adaptus TM Imaging T...
Page 18 - Unpacking the System
1 - 2 IMAGETEAM™ 2020/5620 System Manual Unpacking the System After you open the shipping carton containing the product, take the following steps: • Check to make sure everything you ordered is present. • Save the shipping container for later storage or shipping. • Check for damage during shipment. ...
Page 19 - Charging Information
IMAGETEAM™ 2020/5620 System Manual 1 - 3 Cordless System: Main Components About the Battery Use only the Li-ion battery packs provided by Hand Held Products. The use of any battery pack not sold by Hand Held Products will void your warranty and may result in damage to your unit. Power is supplied to...
Page 20 - Battery Recommendations; Proper Disposal of the Battery
1 - 4 IMAGETEAM™ 2020/5620 System Manual Battery Recommendations • Batteries are shipped approximately 30% to 60% charged and should be fully charged for maximum charge capacity. • The battery is a lithium ion cell and can be used without a full charge, as well as can be charged without fully discha...
Page 21 - Base Charge Mode
IMAGETEAM™ 2020/5620 System Manual 1 - 5 Base Charge Mode In order for the battery to be charged, there must be enough voltage for the circuitry to work. There are three conditions during which power can be supplied to the base: Condition 1: 9VDC power supply connected to the barrel connector Condit...
Page 22 - Linking Scanner to Base; Unlinking the Scanner; Link Modes
1 - 6 IMAGETEAM™ 2020/5620 System Manual Linking Scanner to Base When newly shipped or defaulted to factory settings, the base and scanner are not linked. Once the scanner is placed into the base, the software automatically links the scanner and the base. If the scanner and base have previously been...
Page 24 - Duration; Alarm Sound Type
1 - 8 IMAGETEAM™ 2020/5620 System Manual Out-of-Range Alarm Duration If your scanner is out range of the base, an alarm sounds from both your base and scanner. To activate the alarm options for the scanner or the base and to set the alarm duration, scan the appropriate bar code below and then set th...
Page 25 - IT5620 LED Sequences and Their Meaning
IMAGETEAM™ 2020/5620 System Manual 1 - 9 Data Accumulation Mode Scan the bar codes below to turn data accumulation (batch) mode on and off. If data accumulation mode is on, bar code data is stored when the scanner is out of range of the base and transmitted once the scanner is back in range. Beeper ...
Page 26 - Basic Operation of the Cordless System; Cordless Base
1 - 10 IMAGETEAM™ 2020/5620 System Manual The tables below list the indication and cause of the LED illumination and beeps for the IT2020. Note: Charging only occurs with external power applied to the IT2020 or 12 volt Host power. Basic Operation of the Cordless System Cordless Base The cordless bas...
Page 27 - Cordless Scanner; System Conditions; Linking Process
IMAGETEAM™ 2020/5620 System Manual 1 - 11 a radio signal with randomly changing frequencies, makes the cordless system highly responsive to a wide variety of data collection applications and resistant to noisy RF environments. Bluetooth Class 2 power level provides range of 33 feet (10m) depending o...
Page 28 - Communication Between the Cordless System and the Host
1 - 12 IMAGETEAM™ 2020/5620 System Manual Out of Range and Back into Range with Data Accumulation Mode On The scanner may store a number of symbols (approximately 500 UPC symbols, others may vary) when out of range and then send them to the base when back in range. You will not hear a communication ...
Page 30 - Plug and Play
1 - 14 IMAGETEAM™ 2020/5620 System Manual Reading Techniques The scanner has a view finder that projects a bright red aiming beam that corresponds to its horizontal field of view. The aiming line should be centered horizontally over the bar code; it will not read if the aiming line is in any other d...
Page 31 - Keyboard Wedge Connection
IMAGETEAM™ 2020/5620 System Manual 1 - 15 Note: After you scan one of the codes, power cycle the host terminal to have the interface in effect. Keyboard Wedge Connection If you want your system programmed for an IBM PC AT and compatibles keyboard wedge interface with a USA keyboard, scan the bar cod...
Page 32 - Wand Emulation Plug & Play; Wand Emulation Plug & Play Code 39 Format
1 - 16 IMAGETEAM™ 2020/5620 System Manual Wand Emulation Plug & Play In Wand Emulation mode, the imager decodes the bar code then sends data in the same format as a wand imager. The Code 39 Format converts all symbologies to Code 39. The Same Code Format transmits UPC, EAN, Code 128 and Interlea...
Page 34 - Connecting the Base with USB
1 - 18 IMAGETEAM™ 2020/5620 System Manual Connecting the Base with USB A base can be connected to the USB port of a computer. 1. Connect the appropriate interface cable to the base and to the computer. 2. Program the base for the USB interface. (See "Connecting the Base with USB" on page 1-1...
Page 37 - Connecting the Base with Serial Wedge
IMAGETEAM™ 2020/5620 System Manual 1 - 21 Connecting the Base with Serial Wedge The IT2020 uses TTL signal levels to wedge into an RS-232 serial network. Use only IT2020 serial wedge cables to prevent damage to the base. Refer to Connecting the Base with RS-232 Serial Port on page 2-7 to set the bau...
Page 39 - Terminal Interfaces
IMAGETEAM™ 2020/5620 System Manual 2 - 1 2 Terminal Interfaces Terminal ID If your interface is not a standard PC AT, refer to "Supported Terminals" on page 2-2 through page 2-3 , and locate the Terminal ID number for your PC. Scan the Terminal ID bar code below, then scan the numeric bar co...
Page 40 - Supported Terminals
2 - 2 IMAGETEAM™ 2020/5620 System Manual Supported Terminals Terminal Model(s) Terminal ID DEC VT510, 520, 525 (PC style) 005 DEC VT510, 520, 525 (DEC style LK411) 104 Esprit 200, 400 005 Heath Zenith PC, AT 003* HP Vectra 003* IBM XT 001 IBM PS/2 25, 30, 77DX2 002 IBM AT, PS/2 30–286, 50, 55SX, 60,...
Page 42 - Keyboard Country
2 - 4 IMAGETEAM™ 2020/5620 System Manual Keyboard Country Scan the appropriate country code below to program the keyboard for your country. As a general rule, the following characters are supported, but need special care for countries other than the United States:@ | $ # { } [ ] = / ‘ \ < > ~ ...
Page 43 - Keyboard Style; Regular
IMAGETEAM™ 2020/5620 System Manual 2 - 5 Please refer to Hand Held Products’ website ( www.handheld.com ) for complete keyboard country support information and applicable interfaces. If you need to program a keyboard for a country other than one listed above, scan the Program Keyboard Country bar co...
Page 44 - Emulate External Keyboard; Keyboard Modifiers
2 - 6 IMAGETEAM™ 2020/5620 System Manual Emulate External Keyboard should be scanned if you do not have an external keyboard (IBM AT or equivalent). Note: After scanning the Emulate External Keyboard bar code, you must power cycle your computer. Keyboard Modifiers This modifies special keyboard feat...
Page 45 - Automatic Direct Connect Mode:
IMAGETEAM™ 2020/5620 System Manual 2 - 7 Automatic Direct Connect Mode: This selection can be used if you have an IBM AT style terminal and the system is dropping characters. Default = Off Connecting the Base with RS-232 Serial Port 1. Turn off power to the terminal/computer. 2. Connect the appropri...
Page 47 - Data Bits; Stop Bits; Parity
IMAGETEAM™ 2020/5620 System Manual 2 - 9 RS-232 Word Length: Data Bits, Stop Bits, and Parity Data Bits sets the word length at 7 or 8 bits of data per character. If an application requires only ASCII Hex characters 0 through 7F decimal (text, digits, and punctuation), select 7 data bits. For applic...
Page 48 - Off; On; Host ACK Selection
2 - 10 IMAGETEAM™ 2020/5620 System Manual RS-232 Handshaking RS-232 Handshaking allows control of data transmission from the Imager using software commands from the host device. When this feature is turned Off , no data flow control is used. When Data Flow Control is turned On , the host device susp...
Page 49 - Host ACK Enable
IMAGETEAM™ 2020/5620 System Manual 2 - 11 The commands to which the scanner responds are listed on page 2-12 . The <ESC> is a 1B in hex. A typical command string is y <ESC> x, where “y” is the application work group number, “<ESC> x” is the escape command, and the comma is the term...
Page 51 - Wand Emulation; Wand Emulation Connection; Code 39 Format
IMAGETEAM™ 2020/5620 System Manual 2 - 13 Wand Emulation Wand Emulation Connection The Wand Emulation Connection bar codes should be used if you want to change the terminal ID only , without changing any other imager settings. We recommend using Wand Emulation Plug & Play bar codes to program yo...
Page 53 - Wand Emulation Idle; Wand Emulation Data Block Size
IMAGETEAM™ 2020/5620 System Manual 2 - 15 Wand Emulation Idle The idle describes the state of the scanner when no data is being transmitted. When in Wand Emulation mode, you must set the scanner’s idle state to match the idle state for the device to which the scanner is connected. Default = Idle Hig...
Page 54 - Wand Emulation Overall Checksum
2 - 16 IMAGETEAM™ 2020/5620 System Manual Wand Emulation Overall Checksum When this option is turned on, a computed check character is added at the end of the entire message. The check character is the character which when Exclusive-OR’d with every preceding character of the message yields a result ...
Page 55 - Output; Scanner Functions; Good Read Indicators; Beeper – Good Read
IMAGETEAM™ 2020/5620 System Manual 3 - 1 3 Output Scanner Functions Good Read Indicators Beeper – Good Read The beeper may be programmed On or Off in response to a good read. Turning this option off, only turns off the beeper response to a good read indication. All error and menu beeps are still aud...
Page 57 - Number of Beeps – Good Read; Good Read Delay; User-Specified Good Read Delay
IMAGETEAM™ 2020/5620 System Manual 3 - 3 Number of Beeps – Good Read The number of beeps of a good read can be programmed from 1 - 9. The same number of beeps will be applied to the beeper and LED in response to a good read. For example, if you program this option to have five beeps, there will be f...
Page 58 - Scanner Trigger Modes; Scanner Power Time-Out Timer
3 - 4 IMAGETEAM™ 2020/5620 System Manual Scanner Trigger Modes Manual/Serial Trigger, Low Power You can activate the scanner either by pressing the trigger, or using a serial trigger command (see "Trigger Commands" on page 10-4). When in manual trigger mode, the scanner scans until a bar cod...
Page 60 - Reread Delay
3 - 6 IMAGETEAM™ 2020/5620 System Manual Reread Delay This sets the time period before the scanner can read the same bar code a second time. Setting a reread delay protects against accidental rereads of the same bar code. Longer delays are effective in minimizing accidental rereads at POS (point of ...
Page 61 - Centering Window
IMAGETEAM™ 2020/5620 System Manual 3 - 7 Centering Window Use the centering feature to narrow the scanner’s field of view so the scanner reads only the bar code you want. When centering is turned on, the scanner only reads codes that intersect or are contained within the centering window you set up....
Page 62 - Output Sequence Overview; Default Sequence; Enter Sequence
3 - 8 IMAGETEAM™ 2020/5620 System Manual Example: If you have two bar codes next to one another and the centering window is set to 40% left edge and 60% right edge, only the bar code that intersects that window will be decoded. Output Sequence Overview Require Output Sequence When turned off, the ba...
Page 63 - F F; Discard; Output Sequence Editor; Required
IMAGETEAM™ 2020/5620 System Manual 3 - 9 3. Length Specify what length (up to 9999 characters) of data output will be acceptable for this symbology. Scan the four digit data length from the Programming Chart inside the back cover of this manual. (Note: 50 characters is entered as 0050. 9999 is a uni...
Page 64 - Output Sequence Example
3 - 10 IMAGETEAM™ 2020/5620 System Manual When the output sequence is Off , the bar code data is output to the host as the scanner decodes it. Note: This selection is unavailable when the Multiple Symbols Selection is turned on. Output Sequence Example In this example, you are scanning Code 93, Code...
Page 66 - No Read; Video Reverse
3 - 12 IMAGETEAM™ 2020/5620 System Manual Multiple Symbols When this programming selection is turned On , it allows you to read multiple symbols with a single pull of the scanner’s trigger. If you press and hold the trigger, aiming the scanner at a series of symbols, it reads unique symbols once, be...
Page 67 - Data Editing; Prefix/Suffix Overview; Points to Keep In Mind
IMAGETEAM™ 2020/5620 System Manual 4 - 1 4 Data Editing Prefix/Suffix Overview When a bar code is scanned, additional information is sent to the host computer along with the bar code data. This group of bar code data and additional, user-defined data is called a “message string.” The selections in t...
Page 68 - To Add a Prefix or Suffix:; Example: Add a Suffix to a specific symbology
4 - 2 IMAGETEAM™ 2020/5620 System Manual To Add a Prefix or Suffix: Step 1. Scan the Add Prefix or Add Suffix symbol ( page 4-3 ). Step 2. Determine the 2 digit Hex value from the Symbology Chart (included in the Appendix A ) for the symbology to which you want to apply the prefix or suffix. For exa...
Page 69 - To Clear One or All Prefixes or Suffixes:; To Add a Carriage Return Suffix to all Symbologies
IMAGETEAM™ 2020/5620 System Manual 4 - 3 To Clear One or All Prefixes or Suffixes: You can clear a single prefix or suffix, or clear all prefixes/suffixes for a symbology. When you Clear One Prefix (Suffix), the specific character you select is deleted from the symbology you want. When you Clear All...
Page 70 - Intercharacter, Interfunction, and Intermessage Delays
4 - 4 IMAGETEAM™ 2020/5620 System Manual Suffix Selections Function Code Transmit When this selection is enabled and function codes are contained within the scanned data, the scanner transmits the function code to the terminal. Charts of these function codes are provided in Supported Interface Keys ...
Page 71 - Intercharacter Delay; User Specified Intercharacter Delay
IMAGETEAM™ 2020/5620 System Manual 4 - 5 Intercharacter Delay An intercharacter delay of up to 495 milliseconds may be placed between the transmission of each character of scanned data. Scan the Intercharacter Delay bar code below, then scan the number of milliseconds and the SAVE bar code using the...
Page 72 - Interfunction Delay; Intermessage Delay
4 - 6 IMAGETEAM™ 2020/5620 System Manual Interfunction Delay An interfunction delay of up to 495 milliseconds may be placed between the transmission of each segment of the message string. Scan the Interfunction Delay bar code below, then scan the number of milliseconds and the SAVE bar code using th...
Page 73 - Data Formatting; Data Format Editor Introduction; To Add a Data Format
IMAGETEAM™ 2020/5620 System Manual 5 - 1 5 Data Formatting Data Format Editor Introduction You may use the Data Format Editor to change the scanner’s output. For example, you can use the Data Format Editor to insert characters at certain points in bar code data as it is scanned. The selections in th...
Page 74 - Data Format Editor Commands
5 - 2 IMAGETEAM™ 2020/5620 System Manual Note: The wildcard for all terminal types is 099. Step 4. Code I.D. In the Appendix A , find the symbology to which you want to apply the data format. Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart inside the...
Page 75 - Move Commands; Miscellaneous Commands
IMAGETEAM™ 2020/5620 System Manual 5 - 3 hex values for ASCII codes, see ASCII Conversion Chart (Code Page 1252) on page A-2.) F4 Send “xx” character “nn” times (Insert) leaving cursor in current cursor posi- tion. Syntax = F4xxnn (xx stands for the hex value for an ASCII code, see ASCII Conversion ...
Page 76 - Data Format Editor
5 - 4 IMAGETEAM™ 2020/5620 System Manual E4 Replaces up to 15 characters in the data string with user specified charac- ters. Replacement continues until the E5 command is encountered. Syn- tax = E4nnxx 1 xx 2 yy 1 yy 2 ...zz 1 zz 2 where nn is the total count of both characters to be replaced plus ...
Page 79 - Symbologies; Introduction; All Symbologies On
IMAGETEAM™ 2020/5620 System Manual 6 - 1 6 Symbologies Introduction This programming section contains the following menu selections. Refer to Chapter 10 for settings and defaults. All Symbologies If you want to decode all the symbologies allowable for your scanner, scan the All Symbologies On code. ...
Page 80 - Message Length
6 - 2 IMAGETEAM™ 2020/5620 System Manual Message Length You are able to set the valid reading length of some of the bar code symbologies. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will issue an error beep. You may wish to set the same value for mi...
Page 81 - Codabar Start / Stop Characters; Codabar Check Character; No Check Character
IMAGETEAM™ 2020/5620 System Manual 6 - 3 Codabar <Default All Codabar Settings> Codabar Codabar Start / Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit . Codab...
Page 82 - Codabar Concatenation
6 - 4 IMAGETEAM™ 2020/5620 System Manual When Check Character is set to Validate, but Don’t Transmit , the unit will only read Codabar bar codes printed with a check character, but will not transmit the check character with the scanned data. Codabar Concatenation Codabar supports symbol concatenatio...
Page 83 - Codabar Message Length; Code 39 Start / Stop Characters
IMAGETEAM™ 2020/5620 System Manual 6 - 5 Codabar Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 2-60. Minimum Default = 4, Maximum Default = 60. Code 39 < Default All Code 39 Setti...
Page 84 - Code 39 Check Character; Code 39 Message Length
6 - 6 IMAGETEAM™ 2020/5620 System Manual Code 39, continued Code 39 Check Character No Check Character indicates that the scanner reads and transmits bar code data with or without a check character. When Check Character is set to Validate, but Don’t Transmit , the unit only reads Code 39 bar codes p...
Page 85 - Code 39 Append
IMAGETEAM™ 2020/5620 System Manual 6 - 7 Code 39, continued Code 39 Append This function allows the scanner to append the data from several Code 39 bar codes together before transmitting them to the host computer. When this function is enabled, the scanner stores those Code 39 bar codes that start w...
Page 86 - Full ASCII
6 - 8 IMAGETEAM™ 2020/5620 System Manual Full ASCII If Full ASCII Code 39 decoding is enabled, certain character pairs within the bar code symbol will be interpreted as a single character. For example: $V will be decoded as the ASCII character SYN, and /C will be decoded as the ASCII character #. De...
Page 87 - Code 39 Code Page; < Default All Interleaved 2 of 5 Settings >; Interleaved 2 of 5; Check Digit
IMAGETEAM™ 2020/5620 System Manual 6 - 9 Code 39 Code Page Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the bar code being scanned was created using a code page that is different from the one the h...
Page 88 - Interleaved 2 of 5 Message Length
6 - 10 IMAGETEAM™ 2020/5620 System Manual When Check Digit is set to Validate, but Don’t Transmit , the unit only reads Interleaved 2 of 5 bar codes printed with a check digit, but will not transmit the check digit with the scanned data. When Check Digit is set to Validate and Transmit , the scanner...
Page 89 - Code 93 Message Length; Code 93 Code Page
IMAGETEAM™ 2020/5620 System Manual 6 - 11 Code 93 < Default All Code 93 Settings > Code 93 Code 93 Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 0-80. Minimum Default = 0, Maxi...
Page 90 - Code 2 of 5 Message Length; IATA Code 2 of 5
6 - 12 IMAGETEAM™ 2020/5620 System Manual Code 2 of 5 <Default All Code 2 of 5 Settings> Code 2 of 5 Code 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 1-48. Minimum Def...
Page 91 - IATA Code 2 of 5, continued; IATA Code 2 of 5 Message Length
IMAGETEAM™ 2020/5620 System Manual 6 - 13 IATA Code 2 of 5, continued IATA Code 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 1-48. Minimum Default = 4, Maximum Default = 48. ...
Page 92 - Matrix 2 of 5 Message Length; Check Digits Required
6 - 14 IMAGETEAM™ 2020/5620 System Manual Matrix 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80. Code 11 <Default All Code 11...
Page 93 - Code 11 Message Length
IMAGETEAM™ 2020/5620 System Manual 6 - 15 Code 11, continued Code 11 Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80. Code 128 <Defau...
Page 95 - Code 128 Function Code Transmit; Telepen; Telepen Output
IMAGETEAM™ 2020/5620 System Manual 6 - 17 Code 128 Function Code Transmit By default, Code 128 function codes are not transmitted with Code 128 bar code data. However, if you wish to transmit Code 128 function codes with the bar code data, scan the Function Codes On bar code, below. Telepen <Defa...
Page 96 - Telepen Message Length; UPC A Check Digit
6 - 18 IMAGETEAM™ 2020/5620 System Manual Telepen Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 1-60. Minimum Default = 1, Maximum Default = 60. UPC A <Default All UPC A Settings&...
Page 97 - UPC A Addenda Required
IMAGETEAM™ 2020/5620 System Manual 6 - 19 UPC A Number System The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit it. Default = On. UPC A Addenda This selection adds 2 or 5 digits to the end ...
Page 98 - UPC A Addenda Separator; UPC E
6 - 20 IMAGETEAM™ 2020/5620 System Manual UPC A Addenda Separator When this feature is on, there is a space between the data from the bar code and the data from the addenda. When turned off, there is no space. Default = On. UPC-A/EAN-13 with Extended Coupon Code Use the following codes to enable or ...
Page 99 - UPC E0 and UPC E1; UPC E0 and UPC E1 Expand; UPC E0 and UPC E1 Addenda Required
IMAGETEAM™ 2020/5620 System Manual 6 - 21 UPC E0 and UPC E1 Most U.P.C. bar codes lead with the 0 number system. For these codes, use the UPC E0 selection. If you need to read codes that lead with the 1 number system, use the UPC E1 selection. Default = On (UPC E0) and Off (UPC E1). UPC E0 and UPC E...
Page 101 - UPC E0 Addenda; EAN/JAN 13 Check Digit
IMAGETEAM™ 2020/5620 System Manual 6 - 23 UPC E0 Addenda This selection adds 2 or 5 digits to the end of all scanned UPC E data. Default = Off for both 2 Digit and 5 Digit Addenda. EAN/JAN 13 <Default All EAN/JAN Settings> EAN/JAN 13 EAN/JAN 13 Check Digit This selection allows you to specify ...
Page 102 - EAN/JAN 13 Addenda Required
6 - 24 IMAGETEAM™ 2020/5620 System Manual EAN/JAN 13 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN 13 data. Default = Off for both 2 Digit and 5 Digit Addenda. EAN/JAN 13 Addenda Required When Addenda Required is set to on, the scanner will only read EAN/JAN 13 bar code...
Page 104 - EAN/JAN 8 Addenda Required
6 - 26 IMAGETEAM™ 2020/5620 System Manual EAN/JAN 8 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN 8 data. Default = Off for both 2 Digit and 5 Digit Addenda. EAN/JAN 8 Addenda Required When Addenda Required is set to on, the scanner will only read EAN/JAN 8 bar codes th...
Page 105 - MSI Check Character; Validate and Transmit
IMAGETEAM™ 2020/5620 System Manual 6 - 27 MSI <Default All MSI Settings> MSI MSI Check Character Different types of check characters are used with MSI bar codes. You can program the scanner to read MSI bar codes with Type 10 check characters. Default = Validate Type 10, but Don’t Transmit. Whe...
Page 106 - MSI Message Length; Plessey Code; Plessey Message Length
6 - 28 IMAGETEAM™ 2020/5620 System Manual MSI Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 4-48. Minimum Default = 4, Maximum Default = 48. Plessey Code <Default All Plessey Code...
Page 108 - RSS Expanded Message Length; EAN
6 - 30 IMAGETEAM™ 2020/5620 System Manual RSS Expanded < Default All RSS Expanded Settings > RSS Expanded RSS Expanded Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 4-74. Minim...
Page 109 - China Post Code
IMAGETEAM™ 2020/5620 System Manual 6 - 31 Identifier will be reported as “]C1”. If RSS Emulation is selected, the AIM Symbology Identifier will be reported as “]e0.” Any application that accepts EAN•UCC data can be simplified since it only needs to recognize one data carrier type. Default = EAN•UCC ...
Page 110 - Korea Post Message Length; PosiCode
6 - 32 IMAGETEAM™ 2020/5620 System Manual Korea Post Code <Default All Korea Post Code Settings> Korea Post Code Korea Post Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 2-80. ...
Page 111 - PosiCode A and B; PosiCode Message Length
IMAGETEAM™ 2020/5620 System Manual 6 - 33 PosiCode A and B You have to have PosiCode A and B on to read any of the PosiCode symbologies. PosiCode Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum ...
Page 112 - Codablock F Message Length
6 - 34 IMAGETEAM™ 2020/5620 System Manual Trioptic Code Trioptic Code is used for labeling magnetic storage media. Note: If you are going to scan Code 32 Pharmaceutical codes, Trioptic Code must be off. Codablock F <Default All Codablock F Settings> Codablock F Codablock F Message Length Scan ...
Page 113 - Code 16K Message Length
IMAGETEAM™ 2020/5620 System Manual 6 - 35 Code 16K <Default All Code 16K Settings> Code 16K Code 16K Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 0-160. Minimum Default = 1, M...
Page 114 - Code 49 Message Length
6 - 36 IMAGETEAM™ 2020/5620 System Manual Code 49 Code 49 Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 1-81. Minimum Default = 1, Maximum Default = 81. * On Off Minimum Message Leng...
Page 115 - Interface Keys; Keyboard Function Relationships
IMAGETEAM™ 2020/5620 System Manual 7 - 1 7 Interface Keys Keyboard Function Relationships The following Keyboard Function Code, Hex/ASCII Value, and Full ASCII “CTRL”+ relationships apply to all terminals that can be used with the scanner. Refer to page 2-6 enable Control + ASCII mode. Function Code...
Page 121 - Utilities; To Add a Test Code I.D. Prefix to All Symbologies; Reset Scanner
IMAGETEAM™ 2020/5620 System Manual 8 - 1 8 Utilities To Add a Test Code I.D. Prefix to All Symbologies This selection allows you to turn on transmission of a Code I.D. before the decoded symbology. (See the Symbology Chart, included in the Appendix A , page A-1) for the single character code that id...
Page 122 - Resetting the Standard Product Defaults; Temporary Visual Menu 2003 Configuration
8 - 2 IMAGETEAM™ 2020/5620 System Manual Resetting the Standard Product Defaults If you aren’t sure what programming options are in your scanner, or you’ve changed some options and want the standard product default settings restored, scan the Standard Product Default Settings bar code below. The Men...
Page 123 - Visual Menu 2003 Introduction; Visual Menu 2003 Operations
IMAGETEAM™ 2020/5620 User’s Guide 9 - 1 9 Visual Menu 2003 Visual Menu 2003 Introduction Visual Menu 2003 provides the ability to configure a scanning device by connecting the scanner to the com port of a PC. Visual Menu 2003 allows you to download upgrades to a scanner’s firmware, change programmed...
Page 125 - Serial Programming Commands; Conventions; Menu Command Syntax
IMAGETEAM™ 2020/5620 System Manual 10 - 1 10 Serial Programming Commands The serial programming commands can be used in place of the programming bar codes. Both the serial commands and the programming bar codes will program the IT2020-5. For complete descriptions and examples of each serial programm...
Page 126 - Query Commands
10 - 2 IMAGETEAM™ 2020/5620 System Manual Data The new value for a menu setting, identified by the Tag and Sub-Tag. Storage A single character that specifies the storage table to which the command is applied. An exclamation point ( ! ) performs the com- mand’s operation on the device’s volatile menu...
Page 127 - Concatenation of Multiple Commands; Responses; Examples of Query Commands
IMAGETEAM™ 2020/5620 System Manual 10 - 3 Concatenation of Multiple Commands Multiple commands can be issued within one Prefix/Storage sequence. Only the Tag, SubTag, and Data fields must be repeated for each command in the sequence. If additional commands are to be applied to the same Tag, then the...
Page 128 - Trigger Commands
10 - 4 IMAGETEAM™ 2020/5620 System Manual Example #4: What are the device’s settings for all Codabar selections? Enter: cbr?. Response: CBRENA1[ACK],SSX0[ACK],CK20[ACK],CCT1[ACK],MIN2[ACK],MAX60[ACK],DFT[ACK]. This response indicates that the device’s Codabar Coding Enable (CBRENA) is set to 1, or o...
Page 132 - Output Selections
10 - 8 IMAGETEAM™ 2020/5620 System Manual Wand Emulation Delay Between Blocks 5ms WNDDLY0 2-15 *50ms WNDDLY1 2-15 150ms WNDDLY2 2-15 500ms WNDDLY3 2-15 Wand Emulation Overall Checksum *Off WNDCHK0 2-16 On WNDCHK1 2-16 Output Selections Beeper - Good Read Off BEPBEP0 3-1 *On BEPBEP1 3-1 Beeper Volume...
Page 133 - Prefix/Suffix Selections
IMAGETEAM™ 2020/5620 System Manual 10 - 9 Trigger Mode *Manual Trigger TRGMOD0 3-4 Read Time-Out (0 - 300,000 ms) *0 TRGSTO#### 3-4 Scanner Power Time-Out Timer (1 - 10,800 seconds) *3600 BT_LPT##### 3-5 Automatic Trigger TRGMOD1 3-5 Presentation Mode TRGMOD3 3-5 Hands Free Time-Out (0-300,000 secon...
Page 143 - IMAGETEAM 5620 Product Specifications
IMAGETEAM™ 2020/5620 System Manual 11 - 1 11 Product Specifications IMAGETEAM 5620 Product Specifications Parameter Specification Dimensions (Typical): Height 6.2 inches (15.7 cm) Length 5.3 inches (13.5 cm) Width 3.2 inches (8.1 cm) Weight (with battery) 9.2 ounces (260 g) Light Source 630 nM visib...
Page 144 - IMAGETEAM 2020 Product Specifications
11 - 2 IMAGETEAM™ 2020/5620 System Manual IMAGETEAM 2020 Product Specifications Parameter Specification Dimensions (Typical): Height 3.1 inches (7.9 cm) Length 5.6 inches (14.2 cm) Width 4.3 inches (10.9 cm) Weight 8.8 ounces (250 g) Voltage: DC Barrel 8.5 to 9.5 volts Host Port 4.5-14 volts Current...
Page 145 - IMAGETEAM 5620 Depth of Field
IMAGETEAM™ 2020/5620 System Manual 11 - 3 IMAGETEAM 5620 Depth of Field Minimum Bar Width Maximum Near Field Minimum Far Field (no ambient lighting) 13 mil 100% UPC 1 in (2.5 cm) 24 in (61 cm) 7.5 mil Code 39 4 in (10 cm) 14 in (36 cm) 10 mil Code 39 2 in (5 cm) 18 in (46 cm) 13 mil Code 39 1 in (2....
Page 146 - Standard Cable Pinouts; Keyboard Wedge
11 - 4 IMAGETEAM™ 2020/5620 System Manual Standard Cable Pinouts Keyboard Wedge 10 Pin RJ41 Modular Plug connects to the base 1 2 C ord shield 3 T ied to supply power 4 S upply ground 5 T erminal clock 6 T erminal data 7 S upply power input (Refer to tables on page 11-2 .) 8 K eyboard data 9 K eyboa...
Page 148 - Serial Output
11 - 6 IMAGETEAM™ 2020/5620 System Manual Standard Cable Pinouts Serial Output 10 Pin RJ41 Modular Plug connects to the base 1 2 C ord shield 3 P rog 1 (Tied to supply power for primary cable) 4 S upply ground 5 R eceive data - Serial data to scanner 6 T ransmit data - Serial data from scanner 7 S u...
Page 149 - USB
IMAGETEAM™ 2020/5620 System Manual 11 - 7 Standard Cable Pinouts USB 10 Pin Modular Plug connects to the base 1 2 D ata + 3 T ied to supply power 4 S upply ground 5 6 7 5 volt supply power input 8 9 10 Data -
Page 151 - Maintenance; Cleaning the Scanner’s Window; Inspecting Cords and Connectors; Do not submerge the imager in water. The scanner’s
IMAGETEAM™ 2020/5620 System Manual 12 - 1 12 Maintenance Maintenance Repairs and/or upgrades are not to be performed on this product. These services are to be performed only by an authorized service center. See "Customer Support" on page 13-1 for further information. Cleaning the Scanner’s W...
Page 152 - Replacing the IT2020 Interface Cable:; Troubleshooting Base; End Cap
12 - 2 IMAGETEAM™ 2020/5620 System Manual Replacing the IT2020 Interface Cable: 1. Turn the power to the host system OFF. 2. Disconnect the base’s cable from the terminal or computer. 3. Turn the base upside down. 4. Pull the connector out while maintaining pressure on the connector release clip. 5....
Page 153 - Troubleshooting Scanner
IMAGETEAM™ 2020/5620 System Manual 12 - 3 • There is external power or 12 volt host power. • Charge mode is turned on. ( See "Base Charge Mode" on page 1-5 ) • The battery is not bad or deeply discharged. In some cases, the scanner’s battery may trickle charge to bring it into an acceptable ...
Page 154 - Troubleshooting the Cordless System
12 - 4 IMAGETEAM™ 2020/5620 System Manual If you aren’t sure what programming options have been set in the base, or if you want the factory default settings restored, scan Resetting the Standard Product Defaults on page 10-4. Troubleshooting the Cordless System The scanner must be linked to the base...
Page 155 - Customer Support; Obtaining Factory Service
IMAGETEAM™ 2020/5620 System Manual 13 - 1 13 Customer Support Obtaining Factory Service Hand Held Products provides service for all its products through service centers throughout the world. To obtain warranty or non-warranty service, return the unit to Hand Held Products (postage paid) with a copy ...
Page 156 - Technical Assistance; Limited Warranty
13 - 2 IMAGETEAM™ 2020/5620 System Manual Technical Assistance If you need assistance installing or troubleshooting your scanner, please call your Distributor or the nearest Hand Held Products technical support office: North America/Canada: Telephone: (800) 782-4263, Option 4 (8 a.m. to 6 p.m. EST) ...
Page 159 - Symbology Chart
IMAGETEAM™ 2020/5620 System Manual A - 1 Appendix A Symbology Chart Note: “m” represents the AIM modifier character. Refer to International Technical Specification, Symbology Identifiers, for AIM modifier character details. Note: Prefix / Suffix entries for specific symbologies override the universa...
Page 160 - ASCII Conversion Chart (Code Page 1252
A - 2 IMAGETEAM™ 2020/5620 System Manual ASCII Conversion Chart (Code Page 1252 ) Note: This table applies to U.S. style keyboards. Certain characters may differ depending on your Country Code/PC regional settings. Dec Hex Char Dec Hex Char Dec Hex Char Dec Hex Char 0 00 NUL 160 20 224 40 @ 288 60 ‘...
Page 162 - Code Page Mapping of Printed Bar Codes
A - 4 IMAGETEAM™ 2020/5620 System Manual Code Page Mapping of Printed Bar Codes Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the bar code being scanned was created using a code page that is differe...
Page 164 - Sample Symbols
Sample Symbols UPC A 0 123456 7890 Interleaved 2 of 5 Code 128 EAN 13 1234567890 Code 128 9 780330 290951 654 EAN 8 3210 5 456123 8 0 UPC-E