Disclaimer Welch Allyn reserves the right to make changes in specifications and other information contained in this document without prior notice, and thereader should in all cases consult Welch Allyn to determine whether anysuch changes have been made. The information in this publication doesnot ...
SCANTEAM 5700 User’s Guide The SCANTEAM 5700 product is covered by one or more of the following U.S.Patents: 4,360,798; 4,369,361; 4,387,297; 4,496,831; 4,593,186; 4,603,262; 4,607,156;4,652,750; 4,673,805; 4,736,095; 4,816,660; 4,845,350; 4,896,026; 4,923,281;4,992,717; 5,017,765; 5,047,617; 5,113,...
i SCANTEAM 5700 User’s Guide TABLE OF CONTENTS Section 1 Introduction & Quick Start Menu Section Page Introduction 1–1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Scanner Identification 1–2 . . . . . . . . . . . . . . . . . . . . . . . . . . Connecting the Scanner 1–3 ....
ii SCANTEAM 5700 User’s Guide Section 2 Output Parameters Menu, continued Output Selections Beeper Volume Selection 2–8 . . . . . . . . . . . . . . . . . . . . . . . Output Delays Selection 2–8 . . . . . . . . . . . . . . . . . . . . . . . . Reread Delay Selection 2–9 . . . . . . . . . . . . . . . ....
iv SCANTEAM 5700 User’s Guide Section 8 Maintenance and Troubleshooting Section Page Maintenance 8–1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Troubleshooting 8–3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section 9 Customer Service Section Page Obtaining...
SCANTEAM 5700 User’s Guide 1–2 SCANTEAM 5700 Identification Label Interface Option Option IBM4683 OCIAOCR Bar ImageLaser Out WandEmulation TTLRS–232 TrueRS–232 KeyboardWedge 0* 1 2 3 4** D D D D D D D D D D D Various Various DEC Only RS–232Wedge D ➌ ➋ ➌ ➊ Model Number 5X00/A–12 Scanner Identificatio...
1–3 SCANTEAM 5700 User’s Guide Connecting the Scanner Install the scanner by following the steps shown below: ➊ Turn off the power to the host system. ➋ Connect the interface cable to the scanner and to the terminal/computer. Keyboard Wedge Interface Example Disconnect 1 2 3 ➌ Turn on the power to t...
SCANTEAM 5700 User’s Guide 1–4 In. Typical Depth of Field in Inches/Centimeters Cm. 0 0 2 5.08 4 10.2 6 15.2 8 20.3 10 25.4 12 30.5 14 35.6. 16 40.6 18 45.7 20 50.8 22 55.9 24 61 26 66 28 71.1 30 76.2 32 81.3 In. Cm. 9.65 24.511 9.65 24.511 5 mil 2.5 3.5 7.5 mil 2 7 20mil 1.5 18 40 mil 3.5 26 55 mil...
1–7 SCANTEAM 5700 User’s Guide IBM PC AT and Compatibles Interface (Default) IBM PC, Wand Emulation Inter face IBM PS/2 and Compatibles Interface IBM PC XT and Compatibles Interface These bar codes also program a carriage return (CR) suffix. (also PS/2 30-286, 50, 55SX, 60, 70, 70-061, 70-121, 80) (...
SCANTEAM 5700 User’s Guide 1–8 IBM 4683 Port 5B Interface IBM 4683 Inter face IBM 4683 Port 9B HHBCR–1 Interface IBM 4683 Port 9B HHBCR–2 Interface IBM 4683 Port 17 Interface EAN 8 0C Code 39 00 0A 0B EAN 13 16 I 2 of 5 00 0D 0B UPC A 0D Code 128 00 18 0B UPC E 0A Symbology Suffix Symbology Prefix T...
1–9 SCANTEAM 5700 User’s Guide The bar code above also programs the following parameters: Spectra-Physics OCIA Interface OCIA Inter face NCR OCIA Short Form Format (Eight Bit) Interface NCR OCIA Long Form Format (Nine Bit) Interface EAN 8 06 06 UPC A 01 EAN 13 06 UPC E 05 Symbology Suffix Symbology ...
SCANTEAM 5700 User’s Guide 1–10 The bar code above also programs the following parameters: EAN 8 0C UPC A 0D EAN 13 16 UPC E 0A Code 128 1D EAN 8 17 UPC A 17 EAN 13 17 UPC E 17 I 2 of 5 03 ( Application Dependent ) Fujitsu OCR Interface OCR, RS232 Inter face IBM OCR (Port 21) Interface Symbology Suf...
1–11 SCANTEAM 5700 User’s Guide Supported Terminals Terminal Model(s) Terminal I.D. ADI 1496 72 Apple Desktop Bus ADB MAC Classic, SE SE30, II (All) 49 Bull BDS–7 (HDS–7) 35 Burroughs B25 75 Decision Data DDC3596, 3597 30 DEC VT–220, 320, 330, 340 420 04 Esprit 200, 400 05 Falco 5220 47 Heath Zenith...
1–13 SCANTEAM 5700 User’s Guide Show Software Revision Factory Default Settings Reset Factory Settings Status Check Program Carriage Return Suffix Quick Suffix Selections Clear Bar Code Suffix Scanning the Factory Default Settings bar code resets the scanner to the original factory settings, clearin...
1–15 SCANTEAM 5700 User’s Guide Same Code Wand Emulation Selection [ ✱ Code 39 Wand Emulation Selection Code 39 Wand Emulation Selection Same Code Wand Emulation Selection RS-232 Selection RS-232 Selection Laser Emulation Selection Laser Emulation Selection [ Supports Code 39, UPC, EAN, Code 128, In...
SCANTEAM 5700 User’s Guide 1–16 Dual Inter face Enable/Disable Selection Power Up Delay Laser Emulation Power Up Delay Selection Switched Power Mode Selections ✱ Switched Power (Low Power) Mode Enable ✱ Disable Constant Power Mode Dual Interface Disable Selection lets you temporarily disable the dua...
2–1 SCANTEAM 5700 User’s Guide Introduction Use this chapter to program the output parameters for the Hand-Held LaserScanner. This programming section contains the following menuing selections: • Prefix and Suffix • Output • Serial Communication (RS-232) • Data Formatter Section 2 Serial Interface M...
2–2 SCANTEAM 5700 User’s Guide Primary Interface Prefix and Suffix The scanner transmits a decoded message after every successful bar coderead. Prefix and Suffix characters are data characters you may assign to be sentbefore and after the transmitted bar code data. Transmitted data frame –> Prefi...
2–3 SCANTEAM 5700 User’s Guide Add Primary Prefix ] Clear All Primary Prefixes Add Primary Suffix ] Primary Inter face Prefix Selection Primary Inter face Suffix Selection Exit Selection for Prefix / Suffix Discard Current Prefix or Suffix Changes Clear All Primary Suffixes ] One or more two-digit n...
2–4 SCANTEAM 5700 User’s Guide Secondary (Dual) Interface Prefix and Suffix The scanner will transmit a decoded message after every successful bar coderead. Prefix and Suffix characters are data characters you may assign to be sentbefore and after the transmitted bar code data. Transmitted data fram...
2–6 SCANTEAM 5700 User’s Guide Example 1: Add Suffix for Specific Symbology You want to send a CR (carriage return) Suffix for UPC only. Prefix and Suffix Examples H Scan the Add Suffix Suffix Selection bar code. H The Symbology Chart indicates that the Hex value of UPC is “63”. Scan 6 and 3 on the ...
2–7 SCANTEAM 5700 User’s Guide Hex Value Symbology Chart Symbology 61 62 63 64 65 66 67 Codabar Code 39 UPC EAN Interleaved 2 of 5 Code 2 of 5 MSI Symbology 68 69 6A 6D 6E 99 Code 11 Code 93 Code 128 Matrix 2 of 5 Plessey All Symbologies (Prefix/Suffix Programming only .) Hex Value Code ID [ a b c d...
2–8 SCANTEAM 5700 User’s Guide Interfunction Delay (x5mS) ] Intermessage Delay (x5mS) ] Output Delays Selection ] A two-digit number is required after scanning this programming bar code. Please scan your selection on the Programming Chart (inside back cover). Intercharacter Delay (x5mS) ] Medium ✱ H...
2–9 SCANTEAM 5700 User’s Guide ✱ None Low (500 milliseconds) Good Read Delay Selection Medium (1.0 second) High (1.5 second) High (1.0 second) Extra High (2.0 seconds) Reread Delay Selection ✱ Low (175 milliseconds) Medium (450 milliseconds) Enable ✱ Disable Laser Voting Selection This selection all...
2–11 SCANTEAM 5700 User’s Guide ✱ Default All Serial Communication Settings ✱ Enable ✱ Disable CTS Check Selection 300 600 Baud Rate Selection 1200 2400 4800 ✱ 9600 19200 38400 This selection allows you to select the software programming feature that checksfor a CTS signal, if your application does ...
2–13 SCANTEAM 5700 User’s Guide ✱ Record Protocol Selection Xon / Xoff Ack / Nak To P2 To P1 and P2 Serial Wedge Output Selection ✱ To P1 This selection allows you to program the scanner for the protocol required byyour application. The protocol is a set of rules concerning the exchange of databetwe...
2–14 SCANTEAM 5700 User’s Guide Data Format Editor This selection provides editing of all input (scanned) data. All Industrial andRetail symbologies can be formatted. You may scan the Clear Data Format bar code if you are certain you want to delete or clear all formats. Use the Data Format Editor by...
2–16 SCANTEAM 5700 User’s Guide Format Editor Commands Chart F1 Send all characters followed by “XX” key or function code, starting from current cursor position. Syntax = F1XX (XX = HEX ASCII character or function code 00–FE HEX). Send Commands F2 Send “NN” characters followed by “XX” key or functio...
2–17 SCANTEAM 5700 User’s Guide You are using an IBM PC AT and are scanning a UPC A bar code with a five digitaddenda (shown below). The bar code has a total of 18 characters, including thenumber system, the check digits, and a space between the main bar code dataand the addenda bar code data. Data ...
3–4 SCANTEAM 5700 User’s Guide This programming selection allows you to re-map the keyboard layout for theselected country. As a general rule, the following characters are not supportedby the scanner for countries other than the United States: @ | $ # { } [ ] = / ‘ \ < > ~ ✱ United States Belg...
3–5 SCANTEAM 5700 User’s Guide Note: The following Enable and Disable programming bar codes apply to SCANTEAM 5700 software prior to software revision level 2.0. NCR 7052 Keypad Selection [ Layout 2 (Calculator) Layout 3 (PC AT) ✱ Layout 1 (Telephone) AT Direct Connect Selection [ NCR 7052 applies t...
3–6 SCANTEAM 5700 User’s Guide Keyboard Style This programming selection allows you to program the scanner to supportspecial keyboard features, such as CAPS LOCK, SHIFT LOCK, Data Entry, andCTRL+ codes. These special keyboard features are shown in the chart below. Default = Style A. Style A [ ASCII ...
3–8 SCANTEAM 5700 User’s Guide Keyboard Style Modifiers This programming selection allows you to program special keyboard features,such as CTRL+ codes and Turbo Mode. Control + ASCII Mode On – If you scan this selection, the scanner sends key combinations for ASCII control characters for values 00–1...
4–1 SCANTEAM 5700 User’s Guide Introduction Use this chapter to program the Hand-Held Laser Scanner for Industrial andRetail Symbology selections. This programming section contains the following menuing selections: • Codabar Selections. • Code 39 Selections. • Code 93 Selections. • Interleaved 2 of ...
4–2 SCANTEAM 5700 User’s Guide ✱ Default All Codabar Settings ✱ Codabar ✱ On Off Start / Stop Characters Transmit ✱ Don’t Transmit Message Length Maximum ] Minimum ] ] A two-digit number is required after scanning this programming bar code. Scan your selection on the Programming Chart (inside back c...
4–3 SCANTEAM 5700 User’s Guide Concatenation Don’t Allow (Concatenation Off) ✱ Allow Require Validate, But Don’t Transmit ✱ No Check Character Validate, And Transmit Check Character Codabar Selection, continued Concatenation Codabar supports symbol concatenation. When you Allow concatenation, the re...
4–4 SCANTEAM 5700 User’s Guide ✱ Default All Code 39 Settings ✱ Code 39 ✱ On Off Transmit ✱ Don’t Transmit Start / Stop Characters Full ASCII ✱ Enable Disable Append Enable ✱ Disable ] A two-digit number is required after scanning this programming bar code. Scan your selection on the Programming Cha...
4–5 SCANTEAM 5700 User’s Guide Validate, But Don’t Transmit ✱ No Check Character Validate, And Transmit Check Character Code 39 Selection, continued Message Length Maximum ] Minimum ] Decoding ✱ Adaptive Traditional Programming Tip: If a symbology will not be used, we recommend turning it off to min...
4–6 SCANTEAM 5700 User’s Guide Code 93 ✱ On Off Code 93 Selection ✱ Default All Code 93 Settings ✱ FULL ASCII CHART [ NUL SOHSTXETXEOTENQACKBELBSHTLFVTFFCRSOSI %U$A$B$C$D$E$F$G$H$I$J$K$L$M$N$O DLEDC1DC2DC3DC4NAKSYNETBCANEMSUBESCFSGSRSUS $P$Q$R$S$T$U$V$W$X$Y$Z%A%B%C%D%E SP!”#$%&’()*+,–./ SPACE /A...
4–7 SCANTEAM 5700 User’s Guide Interleaved 2 of 5 ✱ On Off Message Length Maximum ] Minimum ] Validate, But Don’t Transmit ✱ No Check Digit Validate, And Transmit Check Digit Interleaved 2 of 5 Selection ] A two-digit number is required after scanning this programming bar code. Scan your selection o...
4–9 SCANTEAM 5700 User’s Guide Code 128 ✱ On Off Message Length Maximum ] Minimum ] Code 128 Selection ✱ Default All Code 11 / Code 128 Settings ✱ ] A two-digit number is required after scanning this programming bar code. Scan your selection on the Programming Chart (inside back cover). Code 11 ✱ On...
4–10 SCANTEAM 5700 User’s Guide On ✱ Off Code 128 Function Character Selection When Code 128 Function Character is enabled, the scanner can substitute a<GS> for function character 1. To enable the <GS> substitution, you must scanthe Code 128 Function Character On bar code, and the <GS...
4–11 SCANTEAM 5700 User’s Guide Message Length Maximum ] Minimum ] Message Length Maximum ] Minimum ] Code 49 Selection [ Code 16K Selection [ ] A two-digit number is required after scanning this programming bar code. (16K may accept a 3–digit number.) Scan your selection on the ProgrammingChart (in...
4–12 SCANTEAM 5700 User’s Guide EAN / JAN 13 ✱ On Off EAN / JAN 8 ✱ On Off Check Digit ✱ Transmit Don’t Transmit ✱ Default All EAN / UPC Settings ✱ EAN Selection ISBN Enable ✱ Disable Programming Tip: If a symbology will not be used, we recommend turning it off to minimize the chance of a misread.
4–13 SCANTEAM 5700 User’s Guide UPC A ✱ On Off UPC E0 ✱ On Off UPC E1 On ✱ Off Check Digit ✱ Transmit Don’t Transmit Number System ✱ Transmit Don’t Transmit Version E Expand Expand ✱ Don’t Expand ✱ Default All UPC / EAN Settings ✱ UPC Selection Programming Tip: If a symbology will not be used, we re...
5–2 SCANTEAM 5700 User’s Guide Scanning the Download New Firmware bar code prepares the scanner to be downloaded with new firmware. New firmware is downloaded by using theQuick*Load application software (in the download kit). Quick*Load can performfirmware uploads (reading the device’s memory) and d...
5–3 SCANTEAM 5700 User’s Guide For quick download communication configuration, scan the W + A bar code to temporarily configure the scanner for 9600 baud rate, no parity, 8 data bits, and1 stop bit. Standard receive (RX) and transmit (TX) voltages are also selected.RTS / CTS handshaking is disabled....
6–1 SCANTEAM 5700 User’s Guide NUL 00 2 SOH 01 A STX 02 B ETX 03 C EOT 04 D ENQ 05 E ACK 06 F BEL 07 G BS 08 H HT 09 I LF 0A J VT 0B K FF 0C L CR 0D M SO 0E N SI 0F O DLE 10 P DC1 11 Q DC2 12 R DC3 13 S DC4 14 T NAK 15 U SYN 16 V ETB 17 W CAN 18 X EM 19 Y SUB 1A Z ESC 1B [ FS 1C \ GS 1D ] RS 1E 6 US...
6–2 SCANTEAM 5700 User’s Guide Supported Interface Keys SupportedInterface Keys NUL 00 SOH 01 STX 02 ETX 03 EOT 04 ENQ 05 ACK 06 BEL 07 BS 08 HT 09 LF 0A VT 0B FF 0C CR 0D SO 0E SI 0F DLE 10 DC1 11 DC2 12 DC3 13 DC4 14 NAK 15 SYN 16 ETB 17 CAN 18 EM 19 SUB 1A ESC 1B FS 1C GS 1D RS 1E US 1F ReservedE...
6–4 SCANTEAM 5700 User’s Guide ReservedNew LineN/AN/AN/AN/AN/ANew LineN/ATabN/ATabN/ANew LineN/AEscapeF11InsertF13Back SpaceBack TabF12F1F2F3F4F5F6F7F8F9F10 Supported Interface Keys SupportedInterface Keys NUL 00 SOH 01 STX 02 ETX 03 EOT 04 ENQ 05 ACK 06 BEL 07 BS 08 HT 09 LF 0A VT 0B FF 0C CR 0D SO...
7–1 SCANTEAM 5700 User’s Guide Sectio 7 Product Specifications 7 ounces (198 g)5.8 inches (14.8 cm)5.8 inches (14.8 cm)3.0 inches (7.6 cm) 670 nm visible laser diode (VLD); 5700ALR = 650nmVLD 36 ± 3 scans per second Minimum Reflective Difference = 25% (5700/A);MRD = 40% (5700ALR, 5700/HD) ± 65 degre...
7–2 SCANTEAM 5700 User’s Guide Laser Output only 5700–X0 (Laser Compatible Bar Image) Conventional laser data format is provided at the modular connector in thescanner handle. Signal Function Interface cables normally supplied with scanner model 5700–X0 are terminatedwith an 10 pin modular plug (P1)...
7–4 SCANTEAM 5700 User’s Guide Wand Emulation 5700–X1, 5700–X2 Conventional wand data format is provided at the modular connector in thescanner handle. Signal Function Interface cables normally supplied with scanner model 5700–X1 and 5700–X2are terminated with an 10 pin modular plug (P1) and a 9 pin...
7–5 SCANTEAM 5700 User’s Guide RS–232 5700–X1, 5700–X2 (TTL) and 5700–X3 (True) Decoded output data format is provided at the modular connector in the scannerhandle. Signal Function Interface cables normally supplied with scanner model 5700–X1, 5700–X2(TTL), and 5700–X3 (True) are terminated with an...
8–1 SCANTEAM 5700 User’s Guide The Hand-Held Decoded Output Laser Scanner provides reliable and efficientoperation with a minimum of care. Although specific maintenance is notrequired, the following periodic checks insure dependable scanner operation: Maintenance Cleaning the Scan Window Scanning pe...
8–3 SCANTEAM 5700 User’s Guide Troubleshooting The Hand-Held Decoded Output Laser scanner automatically performsself-tests whenever you turn it on. If your scanner is not functioning properly,review the following Troubleshooting Guide to try to isolate the problem. Troubleshooting Guide Is the power...
9–1 SCANTEAM 5700 User’s Guide European Office Welch Allyn, Ltd. Hondsruglaan 87 D5628 DB EindhovenThe Netherlands Telephone: Int+ 31 40 242 4486Fax: Int+ 31 40 2425672 United Kingdom Office Welch Allyn U.K., Ltd. Dallam CourtDallam LaneWarringtonCheshire WA2 7LTUnited Kingdom Telephone: Int+44–1925...
9–2 SCANTEAM 5700 User’s Guide For service in Asia, please contact your Welch Allyn representative (at addressbelow) or your local distributor. Asia / Pacific Office Welch Allyn 10/F Tung Sun Commercial Centre194–200 Lockhart RoadWanchai, Hong Kong Telephone: Int+852–2511–3050 or 2511–3132 Fax: Int+...
9–3 SCANTEAM 5700 User’s Guide The warranty does not apply to product which have been damaged by improperhandling, shipping, or misuse. The warranty does not apply, if, in the sole opinionof Welch Allyn, Inc., the unit has been damaged by accident, misuse, neglect,improper shipping and handling. Sin...
SCANTEAM 5700 User’s Guide The following chart lists the factory default Serial Interface Menu settings(indicated by a “ ✱ ” on the programming menu pages). Parameter Name PageReference Default Setting Prefix / Suffix Selections Beeper Volume High Page 2–8 Output Selections Code I.D. Transmit Disabl...
SCANTEAM 5700 User’s Guide The following chart lists the factory default Industrial Symbology Menu settings(indicated by a “ ✱ ” on the programming menu pages). Parameter Name PageReference Default Setting Symbology Menu Defaults – Industrial Code 11 Selections Code 11 On Page 4–9 Check Digits Requi...
Code 128 CODE 128 Interleaved 2 of 5 1234567890 Code 39 TEST–SHEET Code 2 of 5 Matrix 2 of 5 123456 6543210 123456–9$ Code 93 UPC A with 5 digit addenda 56098 0 12345 67890 5 EAN 13 9 780330 290951 5700/DO/UG Rev K Skaneateles Falls, New York 13153–0187 P.O. Box 187 4619 Jordan Road
Hand Held Products Manuals
-
Hand Held Products 7400
Manual
-
Hand Held Products 5620
Manual
-
Hand Held Products 5770
Manual
-
Hand Held Products 7900
Manual
-
Hand Held Products Dolphin 7450
Manual
-
Hand Held Products Dolphin 7400
Manual
-
Hand Held Products 3875
Manual
-
Hand Held Products 2070
Manual
-
Hand Held Products 3220
Manual
- Hand Held Products 7400/7450 Manual
-
Hand Held Products 2020
Manual
-
Hand Held Products 3800gPDF