Grizzly Industrial G2536 - Manual

Grizzly Industrial G2536

Grizzly Industrial G2536 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
Page: / 2
Loading the manual

MODEL G2536

2 HP ELECTRIC MOTOR

INSTRUCTION SHEET

Electrocution or fire could

result if this motor is not

grounded correctly or if

your wire connections do

not comply with local and

state codes. Ensure com-

pliance by checking with a

qualified electrician!

Electrical Safety

If you are unsure how to attach wires to terminals,
DO NOT continue. Contact a qualified electrician
for assistance. Connecting wires improperly may
cause them to come loose or contact other wires,
which can cause electrocution, fire, or a short.

Model G2536 Specifications

Power .......................................................... 2 HP
Cycle ............................................................ 60Hz
Voltage ................................................. 110/220V
Prewired ...................................................... 110V
Amps .................................................... 18.6/9.3A
RPM ............................................................. 3450
Phase ........................................................ Single
Class .................................................................. E
Start Capacitor ........................ 400MFD 125VAC

Dimensions .............................. 1

3

8

"D x 2

3

8

"L

Run Capacitor ........................... 40MFD 250VAC

Dimensions .............................. 1

7

8

"D x 3½"L

COPYRIGHT © DECEMBER, 2007 BY GRIZZLY INDUSTRIAL, INC.

WARNING: NO PORTION OF THIS INSTRUCTION SHEET MAY BE REPRODUCED IN ANY SHAPE

OR FORM WITHOUT THE WRITTEN APPROVAL OF GRIZZLY INDUSTRIAL, INC.

#JB10222 PRINTED IN TAIWAN

Replaceable Parts

REF PART #

DESCRIPTION

REF PART #

DESCRIPTION

1

P2536001

MOTOR FAN COVER

6

PC040D

R CAPACITOR 40M 250V 1-7/8 X 3-1/2

2

P2536002

MOTOR FAN

7

P2536007

JUNCTION BOX

3

P2536003

S CAPACITOR COVER

8

P2536008

CENTRIFUGAL SWITCH

4

PC400F

S CAPACITOR 400M 125V 1-3/8 X 2-3/8

9

P2536009

CONTACT PLATE

5

P2536005

R CAPACITOR COVER

Disconnect power when

replacing motor. Failure

to do this may result in

serious personal injury.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Grizzly Industrial Models

All Grizzly Industrial Other