Table of Contents:
- Page 3 – General Information; Unit and System Identification Tags; t %POPUTQJOGBOXIFFMGBTUFSUIBOUIFNBYJNVN; Air Pressure and Suction
- Page 4 – Roof Curb and Mounting Details; Steel; Lifting Information; CAUTION; Single Fan System; Multiple Fan System with Bypass Air Plenum; Vektor-HS with SAVVE Technology
- Page 5 – Duct Installation; Bottom Inlet Duct Connection; Duct Connection to Curb; Side or End Duct Connection; t8JUICZQBTTBJSQMFOVN; Duct to Bypass Air Plenum; t8JUIJTPMBUJPOEBNQFSJOSPPGDVSC; Stack Extensions; Mount roof curb to roof deck in accordance with; System Assembly; NOTE
- Page 6 – Kitchen Roof Mounting Installation; Grease Trap; Typical Commercial Kitchen Installation
- Page 7 – Positive Pressure Trap on Tubular Fan Housing; Fan Drain; Negative Pressure Trap on Bypass Air Plenum; Electrical Connections; Single Phase Layout
- Page 8 – Unit; is adjusted by loosening the inlet cone; Overlap or offset; , is adjusted by loosening the wheel
- Page 9 – Maintenance; Belts; WARNING; Motors; synthetic grease conforming to NLGI Grade 2.; Belt; Belt Tension
- Page 10 – Vektor-HS Nozzle Bearings
- Page 11 – Vektor-H and Vektor-HS Exhaust Fan Parts List and Assembly; Item; Side View; Vektor-HS Nozzle Parts List and Assembly; Top View
- Page 12 – Maintenance Log; Our Commitment
General Safety Information
Only qualified personnel should install this fan system.
Personnel should have a clear understanding of these
instructions and should be aware of general safety
precautions. Improper installation can result in electric
shock, possible injury due to coming in contact with
moving parts, as well as other potential hazards. Other
considerations may be required if high winds or seismic
activity are present. If more information is needed,
contact a licensed professional engineer before moving
forward.
1. Follow all local electrical and safety codes, as well as
the National Electrical Code (NEC), the National Fire
Protection Agency (NFPA), where applicable. Follow
the Canadian Electrical Code (CEC) in Canada.
2. The rotation of the wheel is critical. It must be free
to rotate without striking or rubbing any stationary
objects.
3. Motor must be securely and adequately grounded.
4. Do not spin fan wheel faster than maximum
cataloged fan rpm. Adjustments to fan speed
significantly effects motor load. If the fan RPM is
changed, the motor current should be checked to
make sure it is not exceeding the motor nameplate
amps.
5. Do not allow the power cable to kink or come in
contact with oil, grease, hot surfaces or chemicals.
Replace cord immediately if damaged.
6. Verify that the power source is compatible with the
equipment.
7. Never open access doors to a duct while the fan is
running.
DANGER
Always disconnect power before working on or near a
fan. Lock and tag the disconnect switch or breaker to
prevent accidental power up.
CAUTION
When servicing the fan, motor may be hot enough
to cause pain or injury. Allow motor to cool before
servicing.
CAUTION
Precaution should be taken in explosive atmospheres.
Vektor
®
-H
Vektor
®
-HS
Table of Contents
General Safety Information . . . . . . . . . . . . . . . . . . . . . . 1
Receiving / Unpacking / Handling / Storage . . . . . . . 2
Inspection and Maintenance during Storage . . . . . . . 2
Removing
from
Storage
. . . . . . . . . . . . . . . . . . . . . . . 3
General Information
Unit and System Identification . . . . . . . . . . . . . . . . . . 3
Pre-Installation
Information
. . . . . . . . . . . . . . . . . . . . 3
Electrical
Disconnects
. . . . . . . . . . . . . . . . . . . . . . . . 3
Moving Parts / Guards . . . . . . . . . . . . . . . . . . . . . . . . 3
Air Pressure and Suction . . . . . . . . . . . . . . . . . . . . . . 3
Lifting Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Roof Curb and Mounting Details . . . . . . . . . . . . . . . . . 4
Duct Installation - Bottom Inlet . . . . . . . . . . . . . . . . . . 5
Side
or
End
. . . . . . . . . . . . . . . . . . . 5
Stack Extensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
System Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Kitchen Roof Mounting Installation . . . . . . . . . . . . . . . . 6
Plenum Drainage Piping and Trap Detail . . . . . . . . . . . 7
Electrical Connections . . . . . . . . . . . . . . . . . . . . . . . . . 7
Variable Frequency Drive . . . . . . . . . . . . . . . . . . . . . . . 8
Pre-Start-Up Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Maintenance
Belts / Fasteners and Set Screws . . . . . . . . . . . . . . . 9
Motors
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Fan
Shaft
Bearings
. . . . . . . . . . . . . . . . . . . . . . . . . . 9
Bearing
Relubication
Schedule
. . . . . . . . . . . . . . . . 10
Vektor-HS Nozzle Bearings . . . . . . . . . . . . . . . . . . . 10
Damper
Actuators
. . . . . . . . . . . . . . . . . . . . . . . . . . 10
Parts List and Assembly . . . . . . . . . . . . . . . . . . . . . . . 11
Maintenance Log . . . . . . . . . . . . . . . . . . . . . . Backcover
Our Commitment . . . . . . . . . . . . . . . . . . . . . . Backcover
Installation, Operation and Maintenance Manual
Please read and save these instructions for future reference. Read carefully before attempting to assemble,
install, operate or maintain the product described. Protect yourself and others by observing all safety
information. Failure to comply with instructions could result in personal injury and/or property damage!
1
Vektor
®
-H and Vektor
®
-HS Laboratory Exhaust System
®
®
Document #469003
Model Vektor
®
-H and Vektor
®
-HS
Laboratory Exhaust System
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
General Information To ensure a successful installation, the instructions in this manual should be read and adhered to. Failure to comply with proper installation procedures may void the warranty. Unit and System Identification Tags Each fan has a permanently affixed manufacturer’s engraved metal name...
Roof Curb and Mounting Details The figures below illustrates three common methods used to install Vektor systems. Methods used to attach a Vektor unit are dependent on local codes, roof construction design and roof construction materials. Consult an architect or structural engineer for proper means o...
Option 1: t/PJTPMBUJPOEBNQFSJOSPPGDVSC t#PUUPNJOMFUPOCZQBTTBJSQMFOVN Duct Installation Bottom Inlet Duct Connection The end of the duct (customer-supplied) is secured between the roof curb’s top edge and the curb cap of either the Vektor-H or bypass air plenum. If an isolation damper is present in t...