Greenheck ERH-90 - Manual

Greenheck ERH-90

Greenheck ERH-90 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
Page: / 20

Table of Contents:

  • Page 3 – INSTALLATION; See page 6 for more detail on appropriate clearances.; LIFTING; THE USE OF ALL LIFTING LUGS IS; Lifting should only be done with all; UNIT WEIGHTS; BASIC OPERATION; Model; Dimensions shown are in inches.; FIGURE 2
  • Page 4 – DUCT WORK CONNECTIONS; ROOF CURB MOUNTING
  • Page 5 – WEATHERHOODS; Air Fan; TYPICAL CONTROL CENTER COMPONENTS; FIGURE 5
  • Page 6 – SERVICE CLEARANCES / ACCESS PANEL LOCATIONS for Model ERH; refer to FIGURES 6 and 7 below for these dimensions.; FIGURE 6; TOP VIEW; FIGURE 7
  • Page 7 – WATER COIL LOCATION AND CONNECTION; NPT; TABLE 5; FIGURE 8
  • Page 8 – ELECTRIC HEATER APPLICATION/OPERATION; ELECTRICAL CONNECTIONS; Electric Preheater
  • Page 9 – Timer Scale; minor field adjustments
  • Page 10 – Testing; ECONOMIZER APPLICATION/OPERATION
  • Page 11 – the “Trouble Shooting” section of this manual if a problem develops.; START UP CHECKS; THEY PREVENT THE ENTRY OF FOREIGN OBJECTS SUCH AS LEAVES, BIRDS, ETC.; Disconnect and lock-out all power switches to fan.; Special Tools Required
  • Page 12 – Leak test thermal system to insure tight connections.; FAN RPM; Do not operate units with access doors/panels
  • Page 13 – ROUTINE MAINTENANCE; FAN BELTS; MOTORS
  • Page 14 – Internal; VIBRATION; TABLE 7
  • Page 15 – WATER COIL MAINTENANCE; FILTERS; TEST THE SPRAY PRESSURE; over a small corner of the coil to determine if the fins
  • Page 16 – ACCESSING ENERGY RECOVERY WHEEL; ROUTINE ENERGY RECOVERY WHEEL MAINTENANCE; MAINTENANCE OF THE ENERGY RECOVERY WHEEL
  • Page 17 – REMOVING THE ENERGY RECOVERY WHEEL SEGMENTS
  • Page 18 – Energy recovery wheel cassette
  • Page 19 – Trouble Shooting
  • Page 20 – IOM ERH FS; Warranty; GREENHECK; Possible Cause
Loading the manual

**WARNING**

DISCONNECT AND SECURE TO THE "OFF"

POSITION ALL ELECTRICAL POWER TO THE

UNITS PRIOR TO INSPECTION OR SERVICING.

FAILURE TO COMPLY WITH THIS SAFETY

PRECAUTION COULD RESULT IN SERIOUS

INJURY OR DEATH.

**IMPORTANT**

ALL FACTORY PROVIDED LIFTING LUGS MUST

BE USED WHEN LIFTING THE UNITS. FAILURE

TO COMPLY WITH THIS SAFETY PRECAUTION

COULD RESULT IN PROPERTY DAMAGE,

SERIOUS INJURY OR DEATH.

PART #459657

READ AND SAVE THESE INSTRUCTIONS

®

ENERGY RECOVERY UNIT

with HEATING

Models:

ERH-20, 45, 55, & 90

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Heating Section

Energy Recovery Wheel

INSTALLATION SUPPLEMENT

Refer to the following Greenheck installation
supplement for ERH units supplied with Indirect
Gas (IG) heating:

Model PVF, Indirect Gas Fired Furnaces for
Energy Recovery Units, Part #461006

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - INSTALLATION; See page 6 for more detail on appropriate clearances.; LIFTING; THE USE OF ALL LIFTING LUGS IS; Lifting should only be done with all; UNIT WEIGHTS; BASIC OPERATION; Model; Dimensions shown are in inches.; FIGURE 2

3 INSTALLATION The system design and installation should follow accepted industrypractice, such as described in the ASHRAE Handbook. Adequate space should be left around the unit for piping coils anddrains, filter replacement, and maintenance. Sufficient space shouldbe provided on the side of the un...

Page 4 - DUCT WORK CONNECTIONS; ROOF CURB MOUNTING

4 R o tat ion Length of Straight Duct GOOD R o tat ion POOR FIGURE 4 DUCT WORK CONNECTIONS Examples of good and poor fan-to-duct connections are shown below (See FIGURE 4). Airflow out of the fanshould be directed straight or curve the same direction as the fan wheel rotates. Poor duct installation ...

Page 5 - WEATHERHOODS; Air Fan; TYPICAL CONTROL CENTER COMPONENTS; FIGURE 5

5 MainDisconnect On Off Exhaust Hood Control Center Intake Hood INSTALLATION (continued) WEATHERHOODS Supply weatherhood will be factory mounted. The exhaust weatherhood is shipped separately as a kit with itsown instructions. EXHAUST DAMPERS Backdraft dampers for exhaust discharge are mounted in th...