Greenheck HRE-20 - Manual

Greenheck HRE-20

Greenheck HRE-20 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
Page: / 24

Table of Contents:

  • Page 3 – INSTALLATION; LIFTING; THE USE OF ALL; FIGURE 1; UNIT WEIGHTS; Model; All dimensions shown are in inches.; FIGURE 2
  • Page 4 – FIGURE 4; DUCT WORK CONNECTIONS; Supply weatherhood will be factory mounted.; EXHAUST WEATHERHOOD; Factory Supplied Roof Curbs; instructions on page 3 of; ROOF CURB MOUNTING; Curb Outside Dimensions; FIGURE 3
  • Page 5 – ELECTRICAL CONNECTIONS; Air Fan; TYPICAL CONTROL CENTER COMPONENTS; FIGURE 5
  • Page 6 – SERVICE CLEARANCES / ACCESS PANEL LOCATIONS for Model HRE; refer to FIGURES 6 and 7 below for these dimensions.; FIGURE 6; TOP VIEW; FIGURE 7
  • Page 7 – Evaporative Cooling Modules; Indirect Evaporative Cooler; Unit Size
  • Page 8 – Run water supply line to the unit and install; WATER CONTROL OPTIONS FOR EVAPORATIVE COOLING
  • Page 9 – Inadequate cooling; TROUBLE SHOOTING FOR EVAPORATIVE MODULE
  • Page 10 – EVAPORATIVE COOLING MAINTENANCE
  • Page 12 – ELECTRIC HEATER APPLICATION/OPERATION; Post-Heater Control Panel; Disconnect
  • Page 13 – Timer Scale; minor field adjustments
  • Page 14 – Testing; ECONOMIZER APPLICATION/OPERATION; AUTO DRY CYCLE
  • Page 15 – the “Trouble Shooting” section of this manual if a problem develops.; START UP CHECKS; THEY PREVENT THE ENTRY OF FOREIGN OBJECTS SUCH AS LEAVES, BIRDS, ETC.; Disconnect and lock-out all power switches to fan.; Special Tools Required
  • Page 16 – Leak test thermal system to insure tight connections.; FAN RPM; Do not operate units with access doors/panels
  • Page 17 – ROUTINE MAINTENANCE; FAN BELTS; MOTORS
  • Page 18 – Internal; VIBRATION; TABLE 2
  • Page 19 – WATER COIL MAINTENANCE; FILTERS; TEST THE SPRAY PRESSURE; over a small corner of the coil to determine if the fins
  • Page 20 – ACCESSING ENERGY RECOVERY WHEEL; ROUTINE ENERGY RECOVERY WHEEL MAINTENANCE; MAINTENANCE OF THE ENERGY RECOVERY WHEEL
  • Page 21 – REMOVING THE ENERGY RECOVERY WHEEL SEGMENTS
  • Page 23 – Trouble Shooting
  • Page 24 – IOM HRE FS; Warranty; GREENHECK; Possible Cause
Loading the manual

**WARNING**

DISCONNECT AND SECURE TO THE "OFF" POSITION ALL ELECTRICAL POWER TO THE UNITS

PRIOR TO INSPECTION OR SERVICING. FAILURE TO COMPLY WITH THIS SAFETY PRECAUTION

COULD RESULT IN SERIOUS INJURY OR DEATH.

**IMPORTANT**

ALL FACTORY PROVIDED LIFTING LUGS MUST BE USED WHEN LIFTING THE UNITS. FAILURE TO

COMPLY WITH THIS SAFETY PRECAUTION COULD RESULT IN PROPERTY DAMAGE, SERIOUS

INJURY OR DEATH.

PART #461248

READ AND SAVE THESE INSTRUCTIONS

®

HEAT RECOVERY UNIT

WITH EVAPORATIVE COOLING

Models:

HRE-20, 45, 55, & 90

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Indirect Evaporative Cooler

(Exhaust/Scavenger Airstream)

Direct Evaporative Cooler

(Outdoor/Supply Airstream)

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - INSTALLATION; LIFTING; THE USE OF ALL; FIGURE 1; UNIT WEIGHTS; Model; All dimensions shown are in inches.; FIGURE 2

INSTALLATION The system design and installation should followaccepted industry practice, such as described in theASHRAE Handbook. Adequate space should be left around the unit forpiping coils and drains, filter replacement, andmaintenance. Sufficient space should be provided onthe side of the unit f...

Page 4 - FIGURE 4; DUCT WORK CONNECTIONS; Supply weatherhood will be factory mounted.; EXHAUST WEATHERHOOD; Factory Supplied Roof Curbs; instructions on page 3 of; ROOF CURB MOUNTING; Curb Outside Dimensions; FIGURE 3

4 R o tat ion Length of Straight Duct GOOD R o tat ion POOR FIGURE 4 DUCT WORK CONNECTIONS Examples of good and poor fan-to-duct connections are shown below (See FIGURE 4). Airflow out of the fanshould be directed straight or curve the same direction as the fan wheel rotates. Poor duct installation ...

Page 5 - ELECTRICAL CONNECTIONS; Air Fan; TYPICAL CONTROL CENTER COMPONENTS; FIGURE 5

5 MainDisconnect On Off Exhaust Hood Control Center Intake Hood INSTALLATION (continued) ELECTRICAL CONNECTIONS The electrical supply must be compatible with that shown on the nameplate: voltage, phase, and amperagecapacity. The electrical supply line must be properly fused and conform to local and ...

Other Greenheck Models

All Greenheck Other