Greenheck 459968 - Manual
Greenheck 459968 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – OUTDOOR
- Page 3 – Good; Poor; TCF Size; REMOVING FROM STORAGE; drive, motor base and accessories for tightness.; TCF Radial Gap; Installation; Ducted Installations; Inlet Duct Turns –; Installation of a duct turn or elbow; Discharge Duct Turns –; Fan performance is reduced
- Page 4 – Centrifugal Airfoil; DANGER; Non-Ducted Installation; Inlet Clearance; Duct Connections
- Page 5 – WARNING; Vibration; Maintenance; Check belt tension two times during
- Page 6 – Slide sheaves on shafts. Do not drive sheaves on; Motors; CAUTION; Fan Bearing Lubrication; • If possible, relubricate with grease while in operation
- Page 7 – Model QEI; Remove cover plate from drive chamber (outlet
- Page 8 – Warranty; AMCA Publication 410-96, Safety Practices for Users and; Troubleshooting; Problem
Only qualified personnel should install this fan.
Personnel should have a clear understanding of these
instructions and should be aware of general safety
precautions. Improper installation can result in electric
shock, possible injury due to coming in contact with
moving parts, as well as other potential hazards.
Other considerations may be required if high winds
or seismic activity are present. If more information
is needed, contact a licensed professional engineer
before moving forward.
1. Follow all local electrical and safety codes, as
well as the National Electrical Code (NEC) and the
National Fire Protection Agency (NFPA), where
applicable. Follow the Canadian Electric Code
(CEC) in Canada.
2. The rotation of the wheel is critical. It must be free
to rotate without striking or rubbing any stationary
objects.
3. Motor must be securely and adequately grounded.
4. Do not spin fan wheel faster than max cataloged
fan rpm. Adjustments to fan speed significantly
effects motor load. If the fan RPM is changed, the
motor current should be checked to make sure it is
not exceeding the motor nameplate amps.
5. Do not allow the power cable to kink or come in
contact with oil, grease, hot surfaces or chemicals.
Replace cord immediately if damaged.
6. Verify that the power source is compatible with the
equipment.
7. Never open access doors to a duct while the fan is
running.
General Safety Information
DANGER
Always disconnect power before working on or near
a fan. Lock and tag the disconnect switch or breaker
to prevent accidental power up.
CAUTION
When servicing the fan, motor may be hot enough
to cause pain or injury. Allow motor to cool before
servicing.
CAUTION
Precaution should be taken in explosive
atmospheres.
Installation, Operation and Maintenance Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the
product described. Protect yourself and others by observing all safety information. Failure to comply with instructions
could result in personal injury and/or property damage! Retain instructions for future reference.
®
Part #459968
Tubular Centrifugal & Mixed Flow
Model TCF
Tubular Centrifugal Inline Fan
Models QEI and QEID
Mixed Flow Inline Fan
1
Model TCF and Models QEI/QEID Centrifugal
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 Model TCF and Models QEI/QEID Centrifugal ® Remove any accumulations of dirt, water, ice or snow and wipe dry before moving to indoor storage. To avoid “sweating” of metal parts allow cold parts to reach room temperature. To dry parts and packages use a portable electric heater to get rid of any m...
3 Models TCF and Model QEI/QEID Centrifugal ® QEI/QEID Radial Gap Adjust inlet cone position such that the radial gap between the wheel cone and inlet cone is evenly distributed around the wheel. QEI/QEID Alignment If necessary, adjust wheel position by loosening the wheel hub from the fan shaft so ...
4 Model TCF and Models QEI/QEID Centrifugal ® Centrifugal Airfoil Mixed Flow DANGER High voltage electrical input is needed for this equipment. This work should be performed by a qualified electrician. WARNING Disconnect and secure to the “Off” position all electrical power to the fan prior to inspe...