Graham Field 765000 - Manual

Graham Field 765000

Graham Field 765000 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
Page: / 24

Table of Contents:

  • Page 2 – CONTENTS
  • Page 3 – INTRODUCTION; INTENDED USE OF THIS DEVICE; • Aid in the treatment and prevention of stage 1, 2, 3 and
  • Page 4 – IMPORTANT SAFETY PRECAUTIONS; Caution: Indicates a potential hazard or unsafe prac-; immediately; WARNING
  • Page 5 – only; WARNING: Maximum patient weight capacity for this
  • Page 6 – equipment specified by the bed manufacturer may not; CAUTION
  • Page 7 – EQUIPMENT SYMBOLS; please consult your local city office, household waste disposal
  • Page 8 – PRODUCT DESCRIPTION; PUMP AND MATTRESS SYSTEM; pump and mattress system
  • Page 9 – Front panel, first row; The auto-adjust button
  • Page 11 – Front panel, third row; The panel lock button sets the
  • Page 12 – Low pressure indicator:; Check to ensure all connections are properly and se; Power failure indicator:; indicator illuminates, and the alarm sounds, when there is
  • Page 13 – INSTALLATION; UNPACKING; carrier and your Graham-Field equipment provider.; PUMP AND MATTRESS SETUP; bed frame ensure that the foot; Caution: Place the device in a; into place before continuing.; Caution: Ensure that the air hoses are not kinked or
  • Page 15 – OPERATION; GETTING STARTED; ters alternate therapy mode.; QUICK DISCONNECT; Pull the power plug from the wall connector to disconnect
  • Page 16 – TRANSPORT CAP; In case of power failure or trans; CPR FUNCTION; If CPR must be performed on the patient while the mat
  • Page 17 – MAINTENANCE; CLEANING; WARNING: To reduce the risk of increased bacterial; Pump; : Wipe the pump with a clean, damp cloth and mild; Caution: Do not use phenolic products or corrosive or; : Wipe the mattress unit with a clean, damp cloth; Caution: Do not clean the mattress with phenolic; sure mattress cover and tubes are connected correctly.
  • Page 18 – Fuse replacement; Replace the fuse holder cover. Ensure that fuse holder; Air filter replacement; Use a small screwdriver to remove; STORAGE; Store mattress and pump in a dust-free environment
  • Page 19 – SPECIFICATIONS; Classification; Mattress; Note: Specifications are subject to change without notice.
  • Page 20 – LIMITED WARRANTY; GF Health Products, Inc. warrants the Lumex
  • Page 21 – APPENDIX A: EMC INFORMATION
Loading the manual

765000

ALTERNATING PRESSURE MATTRESS SYSTEM

WITH ACTIVE SENSOR TECHNOLOGY

USER MANUAL

Important: Do not operate the Mattress System

without first reading and understanding this manual!

Save this manual for future use.
Note: The most current version of this manual can be

found online at www.grahamfield.com

765000-INS-LAB-RevB10

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - CONTENTS

2 765000-INS-LAB-RevB10 CONTENTS INTRODUCTION ..................................................................................... 3 INTENDED USE OF THIS DEVICE ........................................................ 3 IMPORTANT SAFETY PRECAUTIONS .....................................................

Page 3 - INTRODUCTION; INTENDED USE OF THIS DEVICE; • Aid in the treatment and prevention of stage 1, 2, 3 and

765000-INS-LAB-RevB10 3 INTRODUCTION Use this manual for set-up and operation of the Lumex ® AltaDyne ® Sensor Plus 765000 Alternating Pressure Mattress System with Active Sensor Technology. Read all instructions before using the mattress system. Save this manual for future reference. INTENDED USE O...

Page 4 - IMPORTANT SAFETY PRECAUTIONS; Caution: Indicates a potential hazard or unsafe prac-; immediately; WARNING

4 765000-INS-LAB-RevB10 IMPORTANT SAFETY PRECAUTIONS The safety statements presented in this chapter refer to the basic safety information that should be observed by those using this Mattress System. There are additional safety statements in other chapters or sections, which may be the same as or si...