DESCRIPTION
Trabon MJ Series-Flo Divider Valves are designed for lubricating
systems serving machine tools and other comparable equipment.
In many installations the MSP divider valve serves as the Master
divider assembly for an MJ system.
A typical MJ Series-Flo divider assembly (to the right) consists of
an inlet section, end section and three to eight valve sections. One
manifold will serve up to a maximum of 16 lube points.
The MJ valve sections, which have built-in outlet check valves,
are available in various output sizes. Each twin (T) section has 2
outlets, one from each side of the section. Each single (S) section
can have an outlet on either side but the outlet on one side must be
plugged
for the section to operate properly.
FEATURES/ADVANTAGES
Delivers metered amount of lubricant
•
Compact design
•
Simple to install
•
Built-in outlet check valves
•
OPERATION
Operational sequence of an MJ Series-Flo divider valve assembly
is defined as “progressive”. The term progressive means that
each valve section completes its piston stroke, discharging a
measured amount of lubricant to the bearing it serves before the
following valve section operates. As long as lubricant is supplied
under pressure to the inlet section of the divider assembly, valve
sections will continue to operate in a progressive manner. Divider
assemblies always follow a constant discharge pattern. Whenever
lubricant flow ceases, the valving pistons will stop. When flow
resumes it will start again at the same point in the discharge cycle.
Trabon
®
MJ Series-Flo
Divider Valves
SPECIFICATION
Material
Plated Steel
Pressure (max)
2,000 psi (137.89 bar)
Lubricant
Oil or Grease up to NLGI Grade 1
Max Operating Temperature
200ºF (93ºC)
Max Cycle Rate w/Cycle Pin
60 cycles/min.
Torque:
Tie Rod Nut
12 ft lbs
Enclosure Plug
11-13 ft lbs
Outlet Port Plug
6-7 ft lbs
ORDERING INFORMATION - VALVE SECTIONS
Description
Part No.
Old Part No.
5S, 0.010 cu.in. (0.163 cu.cm
3
)*
562500
001-005-001
5T, 0.005 cu.in. (0.081 cu.cm
3
)*
562503
001-005-002
10S, 0.020 cu.in. (0.327 cu.cm
3
)*
562501
001-010-001
10T, 0.010 cu.in. (0.163 cu.cm
3
)*
562504
001-010-002
10S w/Cycle Indicator - RH, 0.020 cu.in. (0.327 cu.cm
3
)*
562508
001-010-601
10T w/Cycle Indicator - RH, 0.010 cu.in. (0.163 cu.cm
3
)*
562510
001-010-602
10S w/Cycle Indicator - LH, 0.020 cu.in. (0.327 cu.cm
3
)*
562512
001-010-611
10T w/Cycle Indicator - LH, 0.010 cu.in. (0.163 cu.cm
3
)*
562513
001-010-612
15S, 0.030 cu.in. (0.491 cu.cm
3
)*
562502
001-015-001
15T, 0.015 cu.in. (0.245 cu.cm
3
)*
562505
001-015-002
15S w/Cycle Indicator - RH, 0.030 cu.in. (0.491 cu.cm
3
)*
562509
001-015-601
15T w/Cycle Indicator - RH, 0.015 cu.in. (0.245 cu.cm
3
)*
562511
001-015-602
15S w/Cycle Indicator - LH, 0.030 cu.in. (0.491 cu.cm
3
)*
–
001-015-611
15T w/Cycle Indicator - LH, 0.015 cu.in. (0.245 cu.cm
3
)*
564205
001-015-612
Inlet
560643
510-992-002
End
560645
510-994-002
3 Section Tie Rod
557515
510-999-030
4 Section Tie Rod
557516
510-999-040
5 Section Tie Rod
557517
510-999-050
6 Section Tie Rod
557518
510-999-060
7 Section Tie Rod
557519
510-999-070
8 Section Tie Rod
557520
510-999-080
Nut for Tie Rod
556371
410-440-010
*Includes one gasket.
Note: The valve size is stamped on each valve section. The volume discharge per
outlet after a complete cycle is indicated by cu.in. (cu.cm
3
)