Graco ti12823a - Manual

Graco ti12823a

Graco ti12823a – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
Page: / 8

Table of Contents:

  • Page 2 – Component Identification; Connect Gun to Siphon Cup; Operation; Adjust Spray Pattern
  • Page 3 – Cleaning Spray Gun; Check Valve Troubleshooting; Poppet Valve Quick Clear
  • Page 4 – Needle Replacement; Removal; Swivel Tube Adjustment; Installation; Material / Fluid Set Selection Guide
  • Page 5 – Troubleshooting
  • Page 6 – Technical Data
  • Page 7 – Parts
  • Page 8 – Graco Standard Warranty
Loading the manual

313317C

HVLP EDGE

Gun

Models: 256855, 257092, 256856

Maximum Fluid Working Pressure: 50 psi (0.35 MPa, 3.5 bar)
Maximum Air Working Pressure: 10 psi (0.07 MPa, 0.7 bar)

Registered Design No. 001147813-0001

Important Safety Instructions

Refer to your sprayer instruction manual for
Pressure Relief and spray instructions. Keep these
instructions.

-

For the application of architectural paints and coatings -

The HVLP Edge gun is not intended to be used on an external compressor

The following Warnings are for the setup, use, grounding, maintenance and repair of this equipment. The exclamation
point symbol alerts you to a general warning and hazard symbols refer to procedure-specific risks. Refer back to these
Warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint
fumes, in work area can ignite or explode. To
help prevent fire and explosion:
•Use equipment only in well ventilated area.
•Eliminate all ignition sources; such as pilot lights,
cigarettes, portable electric lamps, and plastic
drop cloths (potential static arc).

• Keep work area free of debris, including solvent, rags

and gasoline.

• Do not plug or unplug power cords, or turn power or

light switches on or off when flammable fumes are
present.

• Ground all equipment in the work area. See Ground-

ing instructions.

• Hold gun firmly to side of grounded pail when trigger-

ing into pail.

• If there is static sparking or you feel a shock, stop

operation immediately. Do not use equipment until
you identify and correct the problem.

• Keep a working fire extinguisher in the work area.
• When flammable liquid is sprayed or used for flushing

or cleaning, keep sprayer at least 20 feet (6 meters)
away from explosive vapors.

• Do not clean with materials having flash points lower

than 70° F (21° C). Use water-based materials or
mineral spirits-type material only. For complete infor-
mation about your fluid, request the MSDS from the
fluid distributor or retailer.

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.

• Do not operate the unit when fatigued or under the

influence of drugs or alcohol.

• Do not exceed the maximum working pressure or

temperature rating of the lowest rated system compo-
nent. See Technical Data in all equipment manuals.

• Use fluids and solvents that are compatible with

equipment wetted parts. See Technical Data in all
equipment manuals. Read fluid and solvent manufac-
turer’s warnings. For complete information about your
material, request MSDS forms from distributor or
retailer.

• Check equipment daily. Repair or replace worn or

damaged parts immediately with genuine manufac-
turer’s replacement par ts only.

• Do not alter or modify equipment.
• Use equipment only for its intended purpose. Call

your distributor for information.

• Route hoses and cables away from traffic areas,

sharp edges, moving parts, and hot surfaces.

• Do not kink or over bend hoses or use hoses to pull

equipment.

• Keep children and animals away from work area.
• Comply with all applicable safety regulations.

PRESSURIZED ALUMINUM PARTS HAZARD

Do not use 1,1,1-trichloroethane, methylene chlo-
ride, other halogenated hydrocarbon solvents or

fluids containing such solvents in pressurized aluminum
equipment. Such use can cause serious chemical reac-
tion and equipment rupture, and result in death, serious
injury, and property damage.

PERSONAL PROTECTIVE EQUIPMENT

You must wear appropriate protective equipment
when operating, servicing, or in the operating

area of the equipment to help protect you from serious
injury, including eye injury, inhalation of toxic fumes,
burns, and hearing loss. This equipment includes but is
not limited to:

• Protective eyewear and Hearing protection
• Gloves, clothing and respirator as recommended by

the fluid and solvent manufacturer

WARNINGS

ti12761a

ti12761a

ti12870a

257092

256856

256855

ENG

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Component Identification; Connect Gun to Siphon Cup; Operation; Adjust Spray Pattern

Component Identification 2 313317C Component Identification Pressure Relief Procedure The spray gun cup is pressurized by the gun air supply. To reduce the risk of serious injury from pressurized fluid or accidental spray from gun, always turn off the air sup-ply to the gun before removing the spray...

Page 3 - Cleaning Spray Gun; Check Valve Troubleshooting; Poppet Valve Quick Clear

Operation 313317C 3 2. Have spray gun in motion before triggering. Move spray gun in a straight, smooth stroke. Release trigger at end of stroke. Cleaning Spray Gun Before cleaning gun, read all warnings and do Pressure Relief Procedure. 1. Remove siphon cup. Empty spray material from siphon cup. 2....

Page 4 - Needle Replacement; Removal; Swivel Tube Adjustment; Installation; Material / Fluid Set Selection Guide

Needle Replacement 4 313317C Needle Replacement Removal 1. Relieve pressure. 2. Remove air cap (1). 3. Push trigger slide (4) over to NEEDLE REMOVAL position (D) shown on page 2. 4. Remove fluid nozzle (2). 5. Pull needle (3) out. Installation 1. Insert needle (3). 2. Install fluid nozzle (2). 3. Pu...

Other Graco Models

All Graco Other