Page 2 - Contents
Related Manuals 2 3A1149D Contents Related Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 DGM Presence . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Automation Presence . . . . . . . . . . . . . ....
Page 3 - Overview; DGM Presence
Overview 3A1149D 3 Overview This Discrete Gateway Module (DGM) allows the user to control an HFR through an external control device such as a PLC. The DGM will operate in conjunction with the existing Advanced Display Module (ADM) such that both devices can be used to control the machine. Each HFR c...
Page 4 - Typical Installation
Typical Installation 4 3A1149D Typical Installation Key: A Discrete Gateway Module (DGM) B Breakout Board C CAN Cables D 78 Pin D-Sub Cables (Male to Female) E Ground screw F Connects to HFR G Ferrite Suppressor F IG . 1 1 2 A r_24F843_3A1149_1b D B C F E G
Page 5 - Component Identification
Component Identification 3A1149D 5 Component Identification Key: AA Discrete Gateway Module (DGM)AB BaseAC Module Connection ScrewsAD Access CoverAE Module Status LEDsAF CAN ConnectorsAG Rotary SwitchAH Token SlotAJ D-Sub Connection F IG . 2: AA AE AB AC AD AF r_24B681_2B9904_1b r_24B681_2B9904_2b A...
Page 6 - Module Requirements
Module Requirements 6 3A1149D Module Requirements Each DGM requires a 9-30 VDC NEC Class 2 power supply. This is supplied to the DGM through pins 27, 51, 68, 69 on the D-Sub connection. Ground from this sup-ply should only be connected to pin 70 of the D-Sub connection. I/O Setup NOTE: Each DGM is s...
Page 7 - DGM Digital Input Overview
I/O Setup 3A1149D 7 DGM Digital Input Overview The digital inputs function only when power is supplied to pin 51 and there is a ground connection to pin 70. The dig-ital input is rated at 0-30 VDC, and requires an NEC Class 2 power supply connected to pin 51. The DGM provides optical isolation as sh...
Page 8 - DGM Digital Outputs Overview
I/O Setup 8 3A1149D DGM Digital Outputs Overview The digital outputs function only when power is supplied to pins 27, 68, and 69 and there is a ground connection to pin 70. The digital output is rated at 0-30 VDC, and requires an NEC Class 2 power supply connected to pin 27 for supply bank 1, pin 69...
Page 9 - DGM Analog Inputs Overview; DGM Analog Outputs Overview
I/O Setup 3A1149D 9 DGM Analog Inputs Overview The analog inputs function only when the DGM is connected to a power supply through the CAN connection; see Setup , page 14. Each analog input has a corresponding reference (ground) pin. • Type: Sinking • Voltage Rating: 0-10 Vdc • Input Impedance: 20 k...
Page 10 - Primary DGM Pin Assignments
I/O Setup 10 3A1149D Primary DGM Pin Assignments Pin Number DGM Digital Inputs Functional Description 52 1 PLC to DGM Heartbeat 53 2 Dispense Request / Terminate (Shot, Operator modes), or Start/Stop Recirculation (Standby Mode) 54 3 System Stop 55 4 Acknowledge Active Error 56 5 Set Operating Mode,...
Page 12 - Secondary DGM Pin Assignments
I/O Setup 12 3A1149D Secondary DGM Pin Assignments Pin Number DGM Digital Inputs Functional Description 52 1 Set Zone 1 On 53 2 Set Zone 2 On 54 3 Set Zone 3 On 55 4 Set Zone 4 On 56 5 Accept Zone 1 Setpoint Change 57 6 Accept Zone 2 Setpoint Change 58 7 Accept Zone 3 Setpoint Change 59 8 Accept Zon...
Page 16 - Operation; Primary DGM Digital Inputs; Digital Input 1: PLC to DGM Heartbeat
Operation 16 3A1149D Operation Primary DGM Digital Inputs See DGM Digital Inputs table in the Primary DGM Pin Assignments section beginning on page 10 for pin numbers associated with each bit description. The primary DGM allows the PLC to control and monitor the HFR’s dispensing properties. Digital ...
Page 17 - Digital Input 16
Operation 3A1149D 17 Digital Inputs 9-15: Select Shot Bits The shot selection bits are used to select one of the 100 different defined shots. The user must use the ADM to define each shot. The DGM will use a 7-bit pattern to select one of the shots. The machine must be in Shot mode to select a shot....
Page 18 - Primary DGM Digital Outputs
Operation 18 3A1149D Primary DGM Digital Outputs See DGM Digital Outputs table in the Primary DGM Pin Assignments section beginning on page 10 for pin numbers associated with each bit description. Digital Output 1: DGM to PLC Heartbeat See the DGM to PLC Heartbeat description in the Pri- mary DGM Di...
Page 20 - Primary DGM Analog Outputs
Operation 20 3A1149D Primary DGM Analog Outputs See Analog Outputs table in the Primary DGM Pin Assignments section beginning on page 10 for pin numbers associated with each function. Each analog I/O point has a voltage range of 0-10 VDC. The primary DGM analog outputs are used to provide feedback r...
Page 21 - Secondary DGM I/O Overview
Operation 3A1149D 21 Secondary DGM I/O Overview The secondary DGM is used for controlling and monitor-ing the status of the heaters and chillers. NOTE: The HFR has a total of 8 possible conditioning zones that can be implemented in the system. In any given instance, a maximum of 4 conditioning zones...
Page 22 - Secondary DGM Digital Inputs; Secondary DGM Digital Outputs; Digital Output 2: Ready To Dispense; Digital Output 3: Dispense in Progress; Digital Outputs 4-7: Zone Conditioning On
Operation 22 3A1149D Secondary DGM Digital Inputs Digital Inputs 1-4: Toggle Zone Conditioning On/Off Bits Pulling this input high turns the zone on. Pulling it low turns the zone off. It is also possible to control the zones using the ADM. Digital Inputs 5-8: Accept Zone Setpoint Change Bits NOTE: ...
Page 23 - Set Zone Temperature
Operation 3A1149D 23 Secondary DGM Analog Inputs Set Zone Temperature The external control device interfacing with the DGM can use a varying voltage to specify the desired setpoint for the zone. See Secondary DGM Pin Assignments on page 12. To calculate the voltage to use based on the desired temper...
Page 24 - Secondary DGM Analog Outputs; Actual Zone Temperature
Operation 24 3A1149D Secondary DGM Analog Outputs Actual Zone Temperature The analog output voltages indicate the actual tempera-ture of the material at the specified zone. To calculate the temperature in degrees Fahrenheit based on the output voltage: °F = 13.5 x Voltage + 55 For example, if the ou...
Page 25 - Timing Diagrams; Heartbeat
Timing Diagrams 3A1149D 25 Timing Diagrams Once the last line has been set in any of the following timing diagrams, a 10 mS settle time should be observed to allow the PLC and DGM hardware to reach a steady state. Heartbeat Activate System Stop Button F IG . 6: Heartbeat Timing Diagram F IG . 7: Act...
Page 26 - System Requests; Select an Operating Mode or Shot Number
Timing Diagrams 26 3A1149D System Requests The following are system requests: • Enabling the ADM • Acknowledging Errors • Parking the pump Select an Operating Mode or Shot Number The individual lines can change independently in any order. F IG . 8: System Requests Timing Diagram Input Signal >185...
Page 27 - Change Setpoint
Timing Diagrams 3A1149D 27 Change Setpoint This procedure applies to the following functions: • Changing the dispense pressure setpoint • Changing the material temperature setpoint Toggle On/Off This diagram applies to the following functions: • Open/Close the Dispense Valve • Lock/Unlock the Dispen...
Page 28 - Shot Mode Dispense
Timing Diagrams 28 3A1149D Shot Mode Dispense Shot Mode Dispense and Termination F IG . 12: Shot Mode Dispense Timing Diagram F IG . 13: Shot Mode Dispense Termination Timing Diagram Dispense Request Dispensing Dispense Activity >185 mS Dispense Request Dispense Activity >185 mS >185mS >...
Page 29 - Operator Mode Dispense
Timing Diagrams 3A1149D 29 Operator Mode Dispense F IG . 14: Operator Mode Dispense Timing Diagram Dispense Request Dispense Activity >185 mS >185mS Dispensing
Page 30 - Maintenance; Install Upgrade Token; Check Cable Connections
Maintenance 30 3A1149D Maintenance Install Upgrade Token Note: The DGM connection to the system is temporarily disabled during the installation of the upgrade token. 1. Ensure system is inactive. 2. Remove access cover (D). 3. Insert and press token (T) firmly into slot. NOTE: There is no preferred ...
Page 31 - Troubleshooting; Diagnostic Information
Troubleshooting 3A1149D 31 Troubleshooting Diagnostic Information 7 Fault Code Bit Pattern Table This is an 8-bit pattern indicating the current error num-ber in the system. The bit pattern is accompanied by the Error Present bit. If the PLC displays error messages, the PLC program-mer should transl...
Page 34 - Parts
Parts 34 3A1149D Parts * These kits ship with software loaded. Upgrade token 16D942 is listed for reference only. † The DGM must have a ferrite suppressor attached to the DGM end of the long CAN cable. 1 2 2 1 4 6 5 7 3, 9, 10 1 2 11 3, 9, 10 11 r_24f843_3A1149_1b 13 Ref Part Description Quantity 24...
Page 35 - Accessories
Accessories 3A1149D 35 Accessories Technical Data Part Description 124415 CAN Cable Extension, 9.8 ft (3.0 m) 24E898 CAN Cable Extension, 27.9 ft (8.5 m) 24E897 CAN Cable Extension, 52.5 ft (16.0 m) 124654 CAN Splitter, 1 male to 2 female 24B861 78 pin d-sub cable; 50 ft (15.2 m), male to female Pow...
Page 36 - Graco Standard Warranty; Graco Information
All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. Original instructions. This manual contains English. MM 3A1149 Graco Headquarters: Minneapolis Int...