- Page 2 – Instructions; Pressure Relief Valves; It is not; Pressure Relief; Relieve pressure; only; pump element; Installation; SKIN INJECTION HAZARD
- Page 3 – Verify correct port on G3 label is selected.
- Page 4 – International Offices:; The kit includes the following additional parts:; Disconnect power source.
Instructions
G3 Vent Valve Kit
Instructions for installing vent valve. For professional use only.
Part No.:
12 VDC, NPT- 571061; 24 VDC, NPT - 571029
12 VDC, BSPP - 24F537; 24 VDC, BSPP - 24F536
Maximum Working Pressure: 3500 psi (241 bar, 24 MPa)
Kit Parts:
Important Safety Instructions
Read all warnings and instructions in this
manual and the G3 Pump instruction manual
included with your unit. Save these instructions.
NOTICE
All user supplied tubing must be rated for the same
pressure or equipment could be damaged.
6
5
4
2
1
3
ti15466
Ref.
Description
Qty
571029
571061
24F536
24F537
1
VALVE, vent, 12 VDC, NPT
0
1
0
0
VALVE, vent, 24 VDC, NPT
1
0
0
0
VALVE, vent, 12 VDC, BSPP
0
0
0
1
VALVE, vent, 24 VDC, BSPP
0
0
1
0
2
CABLE, 6 ft, vent valve, 2 pin
1
1
1
1
3
FITTING, grease
1
1
1
1
4
PLUG, dryseal, 1/4 NPTF
3
3
3
3
5
SCREW, cap, socket
2
2
2
2
6
GAUGE, pressure, fluid
1
1
1
1
7
ADAPTER, NPT to BSPP (not shown)
0
0
1
1
3A0526E
ENG
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Instructions 2 3A0526E Instructions Pressure Relief Valves The pressure relief valve uses a pressure adjustment screw (a) to set the pres-sure release point. It is not intended as a way to relieve pressure during normal operation but as a protective measure in the event there is an unintended pressu...
Instructions 3A0526E 3 3. Mount vent valve block (1) to a fixed surface near the G3 pump using mounting holes (b) and two socket screws (5). 4. Connect end of cable (2) to the G3 (F IG . 3). NOTE: Verify correct port on G3 label is selected. Locate symbol shown in F IG . 3 on G3 label to select corr...
All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. Original instructions. This manual contains English. MM 3A0526 Graco Headquarters: Minneapolis Int...