3A0427B
EN
Instructions-Parts
Low Flow Fluid
Regulator
Pneumatic controlled fluid regulator provides accurate, positive pressure control of
finishing coatings in low flow applications. For professional use only.
100 psi (0.7 MPa, 7 bar) Maximum Air Inlet Pressure
300 psi (2.1 MPa, 21 bar) Maximum Fluid Inlet Pressure
90 psi (0.63 MPa, 6.3 bar) Maximum Regulated
Fluid Pressure (High Pressure Port, All Models)
Part No. 24C375, Series A
1:1 Ratio, 90 psi (0.63 MPa, 6.3 bar) Maximum
Regulated Fluid Pressure (Low Pressure Port)
Part No. 24E471, Series A
1:2 Ratio, 50 psi (0.35 MPa, 3.5 bar) Maximum
Regulated Fluid Pressure (Low Pressure Port)
Part No. 24E472, Series A
1:3 Ratio, 30 psi (0.21 MPa, 2.1 bar) Maximum
Regulated Fluid Pressure (Low Pressure Port)
Important Safety Instructions
Read all warnings and instructions in this
manual. Save these instructions.
TI15288a
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Warnings 2 3A0427B Contents Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Mount the Fluid Regulator . . . . . . . . . . . . . . . . . . 4 Grounding . . . . . . . . . . . . . . . . . . . . . ...
Installation 4 3A0427B Installation Mount the Fluid Regulator See F IG . 1. Mount the fluid regulator (C) in a location close to the fluid dispense device. A mounting bracket (D) is supplied. See Dimensions on page 14 for mount- ing information. Grounding The equipment must be grounded. Mount the re...
Operation 3A0427B 7 Operation Pressure Relief Procedure 1. Shut off the fluid supply. 2. Leave on the air to the fluid regulator. 3. Trigger the gun to relieve the fluid pressure. 4. Shut off the air supply to the fluid regulator. 5. Open the fluid drain valve to relieve all fluid pres-sure, having ...